Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 8/2011

01-08-2011 | Reply to Letter to the Editor

Reply to Letter to the Editor: Bony Increased-offset Reversed Shoulder Arthroplasty: Minimizing Scapular Impingement While Maximizing Glenoid Fixation

Authors: Pascal Boileau, MD, Gregory Moineau, MD, Yannick Roussanne, MD, Kieran O’Shea, MB, FRCSI

Published in: Clinical Orthopaedics and Related Research® | Issue 8/2011

Login to get access

Excerpt

We thank Drs. Van Tongel and De Wilde for their interest in and comments regarding our article [1]. In the Methods section, they questioned the following statements: “it is unclear what they mean when they say it is already more lateralized. If they mean the center of rotation, then this is not correct. The center of rotation does not change by enlarging the diameter of the glenosphere.” We wrote: “The disc of cancellous bone graft thickness was adjusted according to the size of the sphere. A 10-mm graft was used for a 36-mm sphere and a 7-mm graft for a 42-mm sphere since it is already more lateralized than the 36 mm.” We refer to the humerus and not the center of rotation. As mentioned by Drs. Van Tongel and De Wilde, using a 10-mm autograft and a 36-mm glenosphere [10 + 18 = 28 mm] or a 7-mm autograft and a 42-mm glenosphere [7 + 21 = 28 mm] leads to the same humeral lateralization. This choice in the surgical technique is based on our experience: using a 42-mm glenosphere and a too-thick autograft (10 or 12 mm, for instance), in a patient without glenoid bone loss might cause difficulty at the time of reducing the humerus, which is dislocated posteriorly for glenoid exposure. Our goal with the BIO-RSA technique is to obtain the same humeral lateralization (28 mm), regardless of the size of the sphere. …
Literature
1.
go back to reference Boileau P, Moineau G, Roussanne Y, O’Shea K. Bony increased-offset reversed shoulder arthroplasty: minimizing scapular impingement while maximizing glenoid fixation. Clin Orthop Relat Res. 2011 Feb 1. [Epub ahead of print] Boileau P, Moineau G, Roussanne Y, O’Shea K. Bony increased-offset reversed shoulder arthroplasty: minimizing scapular impingement while maximizing glenoid fixation. Clin Orthop Relat Res. 2011 Feb 1. [Epub ahead of print]
2.
go back to reference Boileau P, Watkinson Dj, Hatzidakis Am, Balg F. Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elbow Surg. 2005;14 (suppl. 1):147S–161S.PubMedCrossRef Boileau P, Watkinson Dj, Hatzidakis Am, Balg F. Grammont reverse prosthesis: design, rationale, and biomechanics. J Shoulder Elbow Surg. 2005;14 (suppl. 1):147S–161S.PubMedCrossRef
3.
go back to reference De Wilde LF, Poncet D, Middernacht B, Ekelund A. Prosthetic overhang is the most effective way to prevent scapular conflict in a reverse total shoulder prosthesis. Acta Orthop. 2010;81:719–726.PubMedCrossRef De Wilde LF, Poncet D, Middernacht B, Ekelund A. Prosthetic overhang is the most effective way to prevent scapular conflict in a reverse total shoulder prosthesis. Acta Orthop. 2010;81:719–726.PubMedCrossRef
4.
go back to reference Frankle M, Siegal S, Pupello D, Saleem A, Mighell M, Vasey M. The Reverse Shoulder Prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency: a minimum two-year follow-up study of sixty patients. J Bone Joint Surg Am. 2005;87:1697–1705.PubMedCrossRef Frankle M, Siegal S, Pupello D, Saleem A, Mighell M, Vasey M. The Reverse Shoulder Prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency: a minimum two-year follow-up study of sixty patients. J Bone Joint Surg Am. 2005;87:1697–1705.PubMedCrossRef
5.
go back to reference Karelse AT, Bhatia DN, De Wilde LF. Prosthetic component relationship of the reverse Delta III total shoulder prosthesis in the transverse plane of the body. J Shoulder Elbow Surg. 2008;17:602–607.PubMedCrossRef Karelse AT, Bhatia DN, De Wilde LF. Prosthetic component relationship of the reverse Delta III total shoulder prosthesis in the transverse plane of the body. J Shoulder Elbow Surg. 2008;17:602–607.PubMedCrossRef
6.
go back to reference Lévigne C, Boileau P, Favard L, Garaud P, Molé D, Sirveaux F, Walch G. Scapular notching in reverse shoulder arthroplasty. J Shoulder Elbow Surg. 2008;17:925–935.PubMedCrossRef Lévigne C, Boileau P, Favard L, Garaud P, Molé D, Sirveaux F, Walch G. Scapular notching in reverse shoulder arthroplasty. J Shoulder Elbow Surg. 2008;17:925–935.PubMedCrossRef
Metadata
Title
Reply to Letter to the Editor: Bony Increased-offset Reversed Shoulder Arthroplasty: Minimizing Scapular Impingement While Maximizing Glenoid Fixation
Authors
Pascal Boileau, MD
Gregory Moineau, MD
Yannick Roussanne, MD
Kieran O’Shea, MB, FRCSI
Publication date
01-08-2011
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 8/2011
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-011-1927-6

Other articles of this Issue 8/2011

Clinical Orthopaedics and Related Research® 8/2011 Go to the issue

Symposium: Bone Quality: From Bench to Bedside

Raman Assessment of Bone Quality

Symposium: Bone Quality: From Bench to Bedside

The Effect of Antiresorptives on Bone Quality