Authors: David Campbell, BMBS, FRACS, PhD, Graham Mercer, BMBS, FRACS, Kjell G. Nilsson, MSc, BVSc, DVSc, Stuart A. Callary, BAppSc

Published in: Clinical Orthopaedics and Related Research® | Issue 3/2010

Login to get access

Abstract

We present the case of a patient with intraoperative femoral fracture during THA, which was repaired using cerclage fixation and insertion of an hydroxyapatite-coated cementless stem. The patient was evaluated postoperatively using radiostereometry during a 2-year course, and despite a large amount of subsidence and rotation, stabilization occurred and was maintained by 6 months. By evaluating the pattern of stem migration after intraoperative fracture, this case shows, even in the presence of instability, a successful clinical outcome can be achieved using an hydroxyapatite-coated cementless stem.
Literature
1.
go back to reference Berend KR, Lombardi AV Jr, Mallory TH, Chonko DJ, Dodds KL, Adams JB. Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years. J Arthroplasty. 2004;19(7 suppl 2):17–21.CrossRefPubMed Berend KR, Lombardi AV Jr, Mallory TH, Chonko DJ, Dodds KL, Adams JB. Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years. J Arthroplasty. 2004;19(7 suppl 2):17–21.CrossRefPubMed
3.
go back to reference Berry DJ. Management of periprosthetic fractures: the hip. J Arthroplasty. 2002;17(4 suppl 1):11–13.CrossRefPubMed Berry DJ. Management of periprosthetic fractures: the hip. J Arthroplasty. 2002;17(4 suppl 1):11–13.CrossRefPubMed
4.
go back to reference Borlin N, Rohrl SM, Bragdon CR. RSA wear measurements with or without markers in total hip arthroplasty. J Biomech. 2006;39:1641–1650.CrossRefPubMed Borlin N, Rohrl SM, Bragdon CR. RSA wear measurements with or without markers in total hip arthroplasty. J Biomech. 2006;39:1641–1650.CrossRefPubMed
5.
go back to reference Bragdon CR, Thanner J, Greene ME, Malchau H, Digas G, Harris WH, Karrholm J. Standing versus supine radiographs in RSA evaluation of femoral head penetration. Clin Orthop Relat Res. 2006;448:46–51.CrossRefPubMed Bragdon CR, Thanner J, Greene ME, Malchau H, Digas G, Harris WH, Karrholm J. Standing versus supine radiographs in RSA evaluation of femoral head penetration. Clin Orthop Relat Res. 2006;448:46–51.CrossRefPubMed
6.
go back to reference Froimson MI, Garino J, Machenaud A, Vidalain JP. Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review. J Arthroplasty. 2007;22:1–7.CrossRefPubMed Froimson MI, Garino J, Machenaud A, Vidalain JP. Minimum 10-year results of a tapered, titanium, hydroxyapatite-coated hip stem: an independent review. J Arthroplasty. 2007;22:1–7.CrossRefPubMed
7.
go back to reference Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed
8.
go back to reference Karrholm J, Borssen B, Lowenhielm G, Snorrason F. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br. 1994;76:912–917.PubMed Karrholm J, Borssen B, Lowenhielm G, Snorrason F. Does early micromotion of femoral stem prostheses matter? 4-7-year stereoradiographic follow-up of 84 cemented prostheses. J Bone Joint Surg Br. 1994;76:912–917.PubMed
9.
go back to reference Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J. Radiostereometry of hip prostheses: review of methodology and clinical results. Clin Orthop Relat Res. 1997;344:94–110.PubMed Karrholm J, Herberts P, Hultmark P, Malchau H, Nivbrant B, Thanner J. Radiostereometry of hip prostheses: review of methodology and clinical results. Clin Orthop Relat Res. 1997;344:94–110.PubMed
10.
go back to reference Krismer M, Biedermann R, Stockl B, Fischer M, Bauer R, Haid C. The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis. J Bone Joint Surg Br. 1999;81:273–280.CrossRefPubMed Krismer M, Biedermann R, Stockl B, Fischer M, Bauer R, Haid C. The prediction of failure of the stem in THR by measurement of early migration using EBRA-FCA. Einzel-Bild-Roentgen-Analyse-femoral component analysis. J Bone Joint Surg Br. 1999;81:273–280.CrossRefPubMed
11.
go back to reference Lindahl H. Epidemiology of periprosthetic femur fracture around a total hip arthroplasty. Injury. 2007;38:651–654.CrossRefPubMed Lindahl H. Epidemiology of periprosthetic femur fracture around a total hip arthroplasty. Injury. 2007;38:651–654.CrossRefPubMed
12.
go back to reference Malchau H, Karrholm J, Wang YX, Herberts P. Accuracy of migration analysis in hip arthroplasty: digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand. 1995;66:418–424.PubMedCrossRef Malchau H, Karrholm J, Wang YX, Herberts P. Accuracy of migration analysis in hip arthroplasty: digitized and conventional radiography, compared to radiostereometry in 51 patients. Acta Orthop Scand. 1995;66:418–424.PubMedCrossRef
13.
go back to reference Meek RM, Garbuz DS, Masri BA, Greidanus NV, Duncan CP. Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem. J Bone Joint Surg Am. 2004;86:480–485.PubMed Meek RM, Garbuz DS, Masri BA, Greidanus NV, Duncan CP. Intraoperative fracture of the femur in revision total hip arthroplasty with a diaphyseal fitting stem. J Bone Joint Surg Am. 2004;86:480–485.PubMed
14.
go back to reference Salemyr MF, Skoldenberg OG, Boden HG, Ahl TE, Adolphson PY. Good results with an uncemented proximally HA-coated stem in hip revision surgery: 62 hips followed for 2–13 years. Acta Orthop. 2008;79:184–193.CrossRefPubMed Salemyr MF, Skoldenberg OG, Boden HG, Ahl TE, Adolphson PY. Good results with an uncemented proximally HA-coated stem in hip revision surgery: 62 hips followed for 2–13 years. Acta Orthop. 2008;79:184–193.CrossRefPubMed
15.
go back to reference Schutzer SF, Grady-Benson J, Jasty M, O’Connor DO, Bragdon C, Harris WH. Influence of intraoperative femoral fractures and cerclage wiring on bone ingrowth into canine porous-coated femoral components. J Arthroplasty. 1995;10:823–829.CrossRefPubMed Schutzer SF, Grady-Benson J, Jasty M, O’Connor DO, Bragdon C, Harris WH. Influence of intraoperative femoral fractures and cerclage wiring on bone ingrowth into canine porous-coated femoral components. J Arthroplasty. 1995;10:823–829.CrossRefPubMed
16.
go back to reference Schwartz JT Jr, Mayer JG, Engh CA. Femoral fracture during non-cemented total hip arthroplasty. J Bone Joint Surg Am. 1989;71:1135–1142.PubMed Schwartz JT Jr, Mayer JG, Engh CA. Femoral fracture during non-cemented total hip arthroplasty. J Bone Joint Surg Am. 1989;71:1135–1142.PubMed
17.
go back to reference Sharkey PF, Hozack WJ, Booth RE Jr, Rothman RH. Intraoperative femoral fractures in cementless total hip arthroplasty. Orthop Rev. 1992;21:337–342.PubMed Sharkey PF, Hozack WJ, Booth RE Jr, Rothman RH. Intraoperative femoral fractures in cementless total hip arthroplasty. Orthop Rev. 1992;21:337–342.PubMed
18.
go back to reference Strom H, Mallmin H, Milbrink J, Petren-Mallmin M, Nivbrant B, Kolstad K. The cone hip stem: a prospective study of 13 patients followed for 5 years with RSA. Acta Orthop Scand. 2003;74:525–530.PubMedCrossRef Strom H, Mallmin H, Milbrink J, Petren-Mallmin M, Nivbrant B, Kolstad K. The cone hip stem: a prospective study of 13 patients followed for 5 years with RSA. Acta Orthop Scand. 2003;74:525–530.PubMedCrossRef
19.
go back to reference Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S. Early migration pattern of the uncemented CLS stem in total hip arthroplasties. Clin Orthop Relat Res. 2007;454:127–132.CrossRefPubMed Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S. Early migration pattern of the uncemented CLS stem in total hip arthroplasties. Clin Orthop Relat Res. 2007;454:127–132.CrossRefPubMed
20.
go back to reference Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S. The effect of early weight bearing on migration pattern of the uncemented CLS stem in total hip arthroplasty. J Arthroplasty. 2007;22:1122–1129.CrossRefPubMed Strom H, Nilsson O, Milbrink J, Mallmin H, Larsson S. The effect of early weight bearing on migration pattern of the uncemented CLS stem in total hip arthroplasty. J Arthroplasty. 2007;22:1122–1129.CrossRefPubMed
21.
go back to reference Stuchin SA. Femoral shaft fracture in porous and press-fit total hip arthroplasty. Orthop Rev. 1990;19:153–159.PubMed Stuchin SA. Femoral shaft fracture in porous and press-fit total hip arthroplasty. Orthop Rev. 1990;19:153–159.PubMed
22.
go back to reference von Schewelov T, Onsten I, Markusson P, Carlsson A. Weight bearing radiographs are not necessary for measurement of polyethylene penetration in total hip prostheses: a radiostereometric study of 111 patients examined in weight-bearing and supine position. Acta Orthop. 2006;77:104–108.CrossRef von Schewelov T, Onsten I, Markusson P, Carlsson A. Weight bearing radiographs are not necessary for measurement of polyethylene penetration in total hip prostheses: a radiostereometric study of 111 patients examined in weight-bearing and supine position. Acta Orthop. 2006;77:104–108.CrossRef
Metadata
Title
Case Report: Cementless Stem Stabilization after Intraoperative Fracture: A Radiostereometric Analysis
Authors
David Campbell, BMBS, FRACS, PhD
Graham Mercer, BMBS, FRACS
Kjell G. Nilsson, MSc, BVSc, DVSc
Stuart A. Callary, BAppSc
Publication date
01-03-2010
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 3/2010
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-009-1082-5

Other articles of this Issue 3/2010

Clinical Orthopaedics and Related Research® 3/2010 Go to the issue