Abstract

Little is known about tibial bone remodeling with TKA and its clinical relevance. We performed a randomized clinical trial to compare tibial bone density changes in cemented components with different bearing designs. Bone density changes were assessed using quantitative computed tomography (qCT)-assisted osteodensitometry. Twenty-eight rotating-platform and 26 fixed-platform cemented TKAs were included. The nonoperated contralateral side was used as a control. CT scans were performed postoperatively and 1 year and 2 years after the index operation. Cancellous bone density loss (up to 12.6% at 2 years) was observed in all proximal tibial regions in both cohorts. In contrast, we found lower cortical bone density loss (up to 3.6% at 2 years). We found no differences in bone loss between fixed- and rotating-platform implants. The decrease of cancellous bone density after TKA suggests stress transfer to the cortical bone.
Literature
1.
go back to reference Abu-Rajab RB, Watson WS, Walker B, Roberts J, Gallacher SJ, Meek RM. Peri-prosthetic bone mineral density after total knee arthroplasty: cemented versus cementless fixation. J Bone Joint Surg Br. 2006;88:606–613.CrossRefPubMed Abu-Rajab RB, Watson WS, Walker B, Roberts J, Gallacher SJ, Meek RM. Peri-prosthetic bone mineral density after total knee arthroplasty: cemented versus cementless fixation. J Bone Joint Surg Br. 2006;88:606–613.CrossRefPubMed
2.
go back to reference Au AG, James Raso V, Liggins AB, Amirfazli A. Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements. J Biomech. 2007;40:1410–1416.CrossRefPubMed Au AG, James Raso V, Liggins AB, Amirfazli A. Contribution of loading conditions and material properties to stress shielding near the tibial component of total knee replacements. J Biomech. 2007;40:1410–1416.CrossRefPubMed
3.
go back to reference Ewald FC. The Knee Society total knee arthroplasty roentgenograhic evaluation and scoring system. Clin Orthop Relat Res. 1989;248:9–12.PubMed Ewald FC. The Knee Society total knee arthroplasty roentgenograhic evaluation and scoring system. Clin Orthop Relat Res. 1989;248:9–12.PubMed
4.
go back to reference Hvid I, Bentzen SM, Jorgensen J. Remodeling of the tibial plateau after knee replacement: CT bone densitometry. Acta Orthop Scand. 1988;59:567–573.PubMed Hvid I, Bentzen SM, Jorgensen J. Remodeling of the tibial plateau after knee replacement: CT bone densitometry. Acta Orthop Scand. 1988;59:567–573.PubMed
5.
go back to reference Karbowski A, Schwitalle M, Eckardt A, Heine J. Periprosthetic bone remodelling after total knee arthroplasty: early assessment by dual energy x-ray absorptiometry. Arch Orthop Trauma Surg. 1999;119:324–326.CrossRefPubMed Karbowski A, Schwitalle M, Eckardt A, Heine J. Periprosthetic bone remodelling after total knee arthroplasty: early assessment by dual energy x-ray absorptiometry. Arch Orthop Trauma Surg. 1999;119:324–326.CrossRefPubMed
6.
go back to reference Li MG, Nilsson KG. The effect of the preoperative bone quality on the fixation of the tibial component in total knee arthroplasty. J Arthroplasty. 2000;15:744–753.CrossRefPubMed Li MG, Nilsson KG. The effect of the preoperative bone quality on the fixation of the tibial component in total knee arthroplasty. J Arthroplasty. 2000;15:744–753.CrossRefPubMed
7.
go back to reference Li MG, Nilsson KG. Changes in bone mineral density at the proximal tibia after total knee arthroplasty: a 2-year follow-up of 28 knees using dual energy x-ray absorptiometry. J Orthop Res. 2000;18:40–47.CrossRefPubMed Li MG, Nilsson KG. Changes in bone mineral density at the proximal tibia after total knee arthroplasty: a 2-year follow-up of 28 knees using dual energy x-ray absorptiometry. J Orthop Res. 2000;18:40–47.CrossRefPubMed
8.
go back to reference Li MG, Nilsson KG. No relationship between postoperative changes in bone density at the proximal tibia and the migration of the tibial component 2 years after total knee arthroplasty. J Arthroplasty. 2001;16:893–900.CrossRefPubMed Li MG, Nilsson KG. No relationship between postoperative changes in bone density at the proximal tibia and the migration of the tibial component 2 years after total knee arthroplasty. J Arthroplasty. 2001;16:893–900.CrossRefPubMed
9.
go back to reference Lonner JH, Klotz M, Levitz C, Lotke PA. Changes in bone density after cemented total knee arthroplasty: influence of stem design. J Arthroplasty. 2001;16:107–111.CrossRefPubMed Lonner JH, Klotz M, Levitz C, Lotke PA. Changes in bone density after cemented total knee arthroplasty: influence of stem design. J Arthroplasty. 2001;16:107–111.CrossRefPubMed
10.
go back to reference Perillo-Marcone A, Taylor M. Effect of varus/valgus malalignment on bone strains in the proximal tibia after TKR: an explicit finite element study. J Biomech Eng. 2007;129:1–11.CrossRefPubMed Perillo-Marcone A, Taylor M. Effect of varus/valgus malalignment on bone strains in the proximal tibia after TKR: an explicit finite element study. J Biomech Eng. 2007;129:1–11.CrossRefPubMed
11.
go back to reference Petersen MM, Gehrchen PM, Ostgaard SE, Nielsen PK, Lund B. Effect of hydroxyapatite-coated tibial components on changes in bone mineral density of the proximal tibia after uncemented total knee arthroplasty: a prospective randomized study using dual-energy x-ray absorptiometry. J Arthroplasty. 2005;20:516–520.CrossRefPubMed Petersen MM, Gehrchen PM, Ostgaard SE, Nielsen PK, Lund B. Effect of hydroxyapatite-coated tibial components on changes in bone mineral density of the proximal tibia after uncemented total knee arthroplasty: a prospective randomized study using dual-energy x-ray absorptiometry. J Arthroplasty. 2005;20:516–520.CrossRefPubMed
12.
go back to reference Petersen MM, Nielsen PT, Lauritzen JB, Lund B. Changes in bone mineral density of the proximal tibia after uncemented total knee arthroplasty: a 3-year follow-up of 25 knees. Acta Orthop Scand. 1995;66:513–516.PubMedCrossRef Petersen MM, Nielsen PT, Lauritzen JB, Lund B. Changes in bone mineral density of the proximal tibia after uncemented total knee arthroplasty: a 3-year follow-up of 25 knees. Acta Orthop Scand. 1995;66:513–516.PubMedCrossRef
13.
go back to reference Petersen MM, Nielsen PT, Lebech A, Toksvig-Larsen S, Lund B. Preoperative bone mineral density of the proximal tibia and migration of the tibial component after uncemented total knee arthroplasty. J Arthroplasty. 1999;14:77–81.CrossRefPubMed Petersen MM, Nielsen PT, Lebech A, Toksvig-Larsen S, Lund B. Preoperative bone mineral density of the proximal tibia and migration of the tibial component after uncemented total knee arthroplasty. J Arthroplasty. 1999;14:77–81.CrossRefPubMed
14.
go back to reference Pitto RP, Bhargava A, Pandit S, Walker C, Munro JT. Quantitative CT-assisted osteodensitometry of femoral adaptive bone remodelling after uncemented total hip arthroplasty. Int Orthop. 2008;32;589–595.CrossRefPubMed Pitto RP, Bhargava A, Pandit S, Walker C, Munro JT. Quantitative CT-assisted osteodensitometry of femoral adaptive bone remodelling after uncemented total hip arthroplasty. Int Orthop. 2008;32;589–595.CrossRefPubMed
15.
go back to reference Pitto RP, Mueller LA, Reilly K, Schmidt R, Munro J. Quantitative computer-assisted osteodensitometry in total hip arthroplasty. Int Orthop. 2007;31:431–438.CrossRefPubMed Pitto RP, Mueller LA, Reilly K, Schmidt R, Munro J. Quantitative computer-assisted osteodensitometry in total hip arthroplasty. Int Orthop. 2007;31:431–438.CrossRefPubMed
16.
go back to reference Reilly K, Munro J, Pandit S, Kress A, Walker C, Pitto RP. Inter-observer validation study of CT-osteodensitometry in total knee arthroplasty. Arch Orthop Trauma Surg. 2007;127:729–731.CrossRefPubMed Reilly K, Munro J, Pandit S, Kress A, Walker C, Pitto RP. Inter-observer validation study of CT-osteodensitometry in total knee arthroplasty. Arch Orthop Trauma Surg. 2007;127:729–731.CrossRefPubMed
17.
go back to reference Saari T, Uvehammer J, Carlsson L, Regner L, Karrholm J. Joint area constraint had no influence on bone loss in proximal tibia 5 years after total knee replacement. J Orthop Res. 2007;25:798–803.CrossRefPubMed Saari T, Uvehammer J, Carlsson L, Regner L, Karrholm J. Joint area constraint had no influence on bone loss in proximal tibia 5 years after total knee replacement. J Orthop Res. 2007;25:798–803.CrossRefPubMed
18.
go back to reference Schmidt R, Pitto RP, Kress A, Ehremann C, Nowak TE, Reulbach U, Forst R, Muller L. Inter- and intraobserver assessment of periacetabular osteodensitometry after cemented and uncemented total hip arthroplasty using computed tomography. Arch Orthop Trauma Surg. 2005;125:291–297.CrossRefPubMed Schmidt R, Pitto RP, Kress A, Ehremann C, Nowak TE, Reulbach U, Forst R, Muller L. Inter- and intraobserver assessment of periacetabular osteodensitometry after cemented and uncemented total hip arthroplasty using computed tomography. Arch Orthop Trauma Surg. 2005;125:291–297.CrossRefPubMed
19.
go back to reference Soininvaara T, Kroger H, Jurvelin JS, Miettinen H, Suomalainen O, Alhava E. Measurement of bone density around total knee arthroplasty using fan-beam dual energy x-ray absorptiometry. Calcif Tissue Int. 2000;67:267–272.CrossRefPubMed Soininvaara T, Kroger H, Jurvelin JS, Miettinen H, Suomalainen O, Alhava E. Measurement of bone density around total knee arthroplasty using fan-beam dual energy x-ray absorptiometry. Calcif Tissue Int. 2000;67:267–272.CrossRefPubMed
20.
go back to reference Soininvaara TA, Miettinen HJ, Jurvelin JS, Alhava EM, Kroger HP. Bone mineral density in the proximal femur and contralateral knee after total knee arthroplasty. J Clin Densitom. 2004;7:424–431.CrossRefPubMed Soininvaara TA, Miettinen HJ, Jurvelin JS, Alhava EM, Kroger HP. Bone mineral density in the proximal femur and contralateral knee after total knee arthroplasty. J Clin Densitom. 2004;7:424–431.CrossRefPubMed
21.
go back to reference Soininvaara TA, Miettinen HJ, Jurvelin JS, Suomalainen OT, Alhava EM, Kroger HP. Periprosthetic tibial bone mineral density changes after total knee arthroplasty: one-year follow-up study of 69 patients. Acta Orthop Scand. 2004;75:600–605.PubMedCrossRef Soininvaara TA, Miettinen HJ, Jurvelin JS, Suomalainen OT, Alhava EM, Kroger HP. Periprosthetic tibial bone mineral density changes after total knee arthroplasty: one-year follow-up study of 69 patients. Acta Orthop Scand. 2004;75:600–605.PubMedCrossRef
22.
go back to reference Sumner DR, Galante JO. Determinants of stress shielding: design versus materials versus interface. Clin Orthop Relat Res. 1992;274:202–212.PubMed Sumner DR, Galante JO. Determinants of stress shielding: design versus materials versus interface. Clin Orthop Relat Res. 1992;274:202–212.PubMed
23.
go back to reference Sundfeldt M, Carlsson LV, Johansson CB, Thomsen P, Gretzer C. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop. 2006;77:177–197.CrossRefPubMed Sundfeldt M, Carlsson LV, Johansson CB, Thomsen P, Gretzer C. Aseptic loosening, not only a question of wear: a review of different theories. Acta Orthop. 2006;77:177–197.CrossRefPubMed
24.
go back to reference Sutherland CJ, Gayou, DE. Artifacts and thresholding in X-ray CT of a cortical bone and titanium composite. J Comput Assist Tomogr. 1996;20:496–503.CrossRefPubMed Sutherland CJ, Gayou, DE. Artifacts and thresholding in X-ray CT of a cortical bone and titanium composite. J Comput Assist Tomogr. 1996;20:496–503.CrossRefPubMed
25.
go back to reference Therbo M, Petersen MM, Varmarken JE, Olsen CA, Lund B. Influence of pre-operative bone mineral content of the proximal tibia on revision rate after uncemented knee arthroplasty. J Bone Joint Surg Br. 2003;85:975–979.CrossRefPubMed Therbo M, Petersen MM, Varmarken JE, Olsen CA, Lund B. Influence of pre-operative bone mineral content of the proximal tibia on revision rate after uncemented knee arthroplasty. J Bone Joint Surg Br. 2003;85:975–979.CrossRefPubMed
26.
go back to reference Walker PS. Biomechanics of total knee replacement designs. In: Mow VC, Huiskes R eds. Basic Orthopaedic Biomechanics and Mechano-biology. 3rd ed. Philadelphia, PA: Lippincott, Williams and Wilkins; 2005:657–702. Walker PS. Biomechanics of total knee replacement designs. In: Mow VC, Huiskes R eds. Basic Orthopaedic Biomechanics and Mechano-biology. 3rd ed. Philadelphia, PA: Lippincott, Williams and Wilkins; 2005:657–702.
27.
go back to reference Wang CJ, Wang JW, Ko JY, Weng LH, Huang CC. Three-year changes in bone mineral density around the knee after a six-month course of oral alendronate following total knee arthroplasty: a prospective randomized study. J Bone Joint Surg Am. 2006;88:267–272.CrossRefPubMed Wang CJ, Wang JW, Ko JY, Weng LH, Huang CC. Three-year changes in bone mineral density around the knee after a six-month course of oral alendronate following total knee arthroplasty: a prospective randomized study. J Bone Joint Surg Am. 2006;88:267–272.CrossRefPubMed
Metadata
Title
Loss of Tibial Bone Density in Patients with Rotating- or Fixed-platform TKA
Authors
Jacob T. Munro, MBChB
Salil Pandit, MBChB
Cameron G. Walker, PhD
Mark Clatworthy, MBChB, FRACS
Rocco P. Pitto, MD, PhD, FRACS
Publication date
01-03-2010
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 3/2010
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-009-0794-x

Other articles of this Issue 3/2010

Clinical Orthopaedics and Related Research® 3/2010 Go to the issue