Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 3/2009

01-03-2009 | Original Article

The Influence of a Suction Device on Fixation of a Cemented Cup using RSA

Authors: A. John Timperley, DPhil, Sarah L. Whitehouse, PhD, Patrick G. Hourigan, MCSP

Published in: Clinical Orthopaedics and Related Research® | Issue 3/2009

Login to get access

Abstract

The quality of technique used at the time of socket cementation is crucial in ensuring a durable long-term result of the implant. We asked whether a new instrument, an aspirator retractor introduced into the wing of the ilium before socket preparation and cementation, would enhance cement fixation as defined by RSA and radiographic examination. We randomized 38 patients into two groups. The surgical technique was identical between the groups with the exception of the use of the aspirator retractor. Patients were followed clinically and with radiostereometry at a minimum of 2 years. We compared gross radiographic appearances, including the depth of penetration of cement and the incidence of postoperative and 2-year radiolucent lines. There was no difference in proximal migration between the two groups. No improvement of fixation was proven from the measured translations and rotations of the socket in the suction group. We found no difference in the number or extent of radiolucent lines or the depth of cement penetration when the iliac suction device was used in conjunction with contemporary cementing techniques. Although the data suggest no short-term advantage in this small study, we will continue to follow these patients presuming there will be improved outcomes in the longer term and since the device provides an easier method of obtaining adequate fixation, especially if technical difficulties are encountered during the pressurization procedure.
Literature
1.
go back to reference Askew AM, Steege JW, Lewis JL, Ranieri JR, Wixson RL. Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res. 1984;1:412–420.PubMedCrossRef Askew AM, Steege JW, Lewis JL, Ranieri JR, Wixson RL. Effect of cement pressure and bone strength on polymethylmethacrylate fixation. J Orthop Res. 1984;1:412–420.PubMedCrossRef
2.
go back to reference Berend ME, Ritter MA. A method for improving acetabular preparation during cemented all-polyethylene acetabular component insertion during total hip arthroplasty. J Arthroplasty. 2002;17:782–784.PubMedCrossRef Berend ME, Ritter MA. A method for improving acetabular preparation during cemented all-polyethylene acetabular component insertion during total hip arthroplasty. J Arthroplasty. 2002;17:782–784.PubMedCrossRef
3.
go back to reference Bland M. An Introduction to Medical Statistics. New York, NY: Oxford University Press; 1995. Bland M. An Introduction to Medical Statistics. New York, NY: Oxford University Press; 1995.
4.
go back to reference Charnley J. Numerical grading of clinical results. Low Friction Arthroplasty of the Hip—Theory and Practice. New York, NY: Springer-Verlag; 1979:20–24. Charnley J. Numerical grading of clinical results. Low Friction Arthroplasty of the Hip—Theory and Practice. New York, NY: Springer-Verlag; 1979:20–24.
5.
go back to reference Cohen J. Statistical Power Analysis for the Behavioral Sciences. Hillsdale, NJ: Lawrence Erlbaum Associates; 1988. Cohen J. Statistical Power Analysis for the Behavioral Sciences. Hillsdale, NJ: Lawrence Erlbaum Associates; 1988.
6.
go back to reference Crites BM, Berend ME, Ritter MA. Technical considerations of cemented acetabular components: a 30-year evaluation. Clin Orthop Relat Res. 2000;381:114–119.PubMedCrossRef Crites BM, Berend ME, Ritter MA. Technical considerations of cemented acetabular components: a 30-year evaluation. Clin Orthop Relat Res. 2000;381:114–119.PubMedCrossRef
7.
go back to reference Dawson J, Fitzpatrick R, Carr A, Murray D. Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg Br. 1996;78:185–190.PubMed Dawson J, Fitzpatrick R, Carr A, Murray D. Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg Br. 1996;78:185–190.PubMed
8.
go back to reference DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed
9.
go back to reference Della Valle CJ, Kaplan K, Jazrawi A, Ahmed S, Jaffe WL. Primary total hip arthroplasty with a flanged, cemented all-polyethylene acetabular component: evaluation at a minimum of 20 years. J Arthroplasty. 2004;19:23–26.PubMedCrossRef Della Valle CJ, Kaplan K, Jazrawi A, Ahmed S, Jaffe WL. Primary total hip arthroplasty with a flanged, cemented all-polyethylene acetabular component: evaluation at a minimum of 20 years. J Arthroplasty. 2004;19:23–26.PubMedCrossRef
10.
go back to reference Flivik G, Kristiansson I, Kesteris U, Ryd L. Is removal of subchondral bone plate advantageous in cemented cup fixation? A randomized RSA study. Clin Orthop Relat Res. 2006;448:164–172.PubMedCrossRef Flivik G, Kristiansson I, Kesteris U, Ryd L. Is removal of subchondral bone plate advantageous in cemented cup fixation? A randomized RSA study. Clin Orthop Relat Res. 2006;448:164–172.PubMedCrossRef
11.
go back to reference Flivik G, Sanfridsson J, Onnerfalt R, Kesteris U, Ryd L. Migration of the acetabular component: effect of cement pressurization and significance of early radiolucency: a randomized 5-year study using radiostereometry. Acta Orthop. 2005;76:159–168.PubMedCrossRef Flivik G, Sanfridsson J, Onnerfalt R, Kesteris U, Ryd L. Migration of the acetabular component: effect of cement pressurization and significance of early radiolucency: a randomized 5-year study using radiostereometry. Acta Orthop. 2005;76:159–168.PubMedCrossRef
12.
go back to reference Garcia-Cimbrelo E, Diez-Vazquez V, Madero R, Munuera L. Progression of radiolucent lines adjacent to the acetabular component and factors influencing migration after Charnley low-friction total hip arthroplasty. J Bone Joint Surg Am. 1997;79:1373–1380.PubMed Garcia-Cimbrelo E, Diez-Vazquez V, Madero R, Munuera L. Progression of radiolucent lines adjacent to the acetabular component and factors influencing migration after Charnley low-friction total hip arthroplasty. J Bone Joint Surg Am. 1997;79:1373–1380.PubMed
13.
go back to reference Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed
14.
go back to reference Herberts P, Malchau H. Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases. Acta Orthop Scand. 2000;71:111–121.PubMedCrossRef Herberts P, Malchau H. Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases. Acta Orthop Scand. 2000;71:111–121.PubMedCrossRef
15.
go back to reference Heyse-Moore GH, Ling RSM. Current cement techniques. In: Marti RK, ed. Progress in Cemented Hip Surgery and Revision. Amsterdam, The Netherlands: Excerpta Medica; 1982:71–86. Heyse-Moore GH, Ling RSM. Current cement techniques. In: Marti RK, ed. Progress in Cemented Hip Surgery and Revision. Amsterdam, The Netherlands: Excerpta Medica; 1982:71–86.
16.
go back to reference Hodgkinson JP, Maskell AP, Paul A, Wroblewski BM. Flanged acetabular components in Charnley hip arthroplasty: ten year follow-up of 350 patients. J Bone Joint Surg Br. 1993;75:464–467.PubMed Hodgkinson JP, Maskell AP, Paul A, Wroblewski BM. Flanged acetabular components in Charnley hip arthroplasty: ten year follow-up of 350 patients. J Bone Joint Surg Br. 1993;75:464–467.PubMed
17.
go back to reference Hogan N, Azhar A, Brady O. An improved acetabular cementing technique in total hip arthroplasty: aspiration of the iliac wing. J Bone Joint Surg Br. 2005;87:1216–1219.PubMedCrossRef Hogan N, Azhar A, Brady O. An improved acetabular cementing technique in total hip arthroplasty: aspiration of the iliac wing. J Bone Joint Surg Br. 2005;87:1216–1219.PubMedCrossRef
18.
go back to reference Krause WR, Krug W, Miller J. Strength of the cement-bone interface. Clin Orthop Relat Res. 1982;163:290–299.PubMed Krause WR, Krug W, Miller J. Strength of the cement-bone interface. Clin Orthop Relat Res. 1982;163:290–299.PubMed
19.
go back to reference Lee AJ, Ling RS. A device to improve the extrusion of bone cement into the bone of the acetabulum in the replacement of the hip joint. Biomed Eng. 1974;9:522–524.PubMed Lee AJ, Ling RS. A device to improve the extrusion of bone cement into the bone of the acetabulum in the replacement of the hip joint. Biomed Eng. 1974;9:522–524.PubMed
20.
go back to reference MacDonald W, Swarts E, Beaver R. Penetration and shear strength of cement-bone interfaces in vivo. Clin Orthop Relat Res. 1993;286:283–288.PubMed MacDonald W, Swarts E, Beaver R. Penetration and shear strength of cement-bone interfaces in vivo. Clin Orthop Relat Res. 1993;286:283–288.PubMed
21.
go back to reference Majkowski RS, Bannister GC, Miles AW. The effect of bleeding on the cement-bone interface: an experimental study. Clin Orthop Relat Res. 1994;299:293–297.PubMed Majkowski RS, Bannister GC, Miles AW. The effect of bleeding on the cement-bone interface: an experimental study. Clin Orthop Relat Res. 1994;299:293–297.PubMed
22.
go back to reference Majkowski RS, Miles AW, Bannister GC, Perkins J, Taylor GJ. Bone surface preparation in cemented joint replacement. J Bone Joint Surg Br. 1993;75:459–463.PubMed Majkowski RS, Miles AW, Bannister GC, Perkins J, Taylor GJ. Bone surface preparation in cemented joint replacement. J Bone Joint Surg Br. 1993;75:459–463.PubMed
23.
go back to reference Murray DW, Fitzpatrick R, Rogers K, Pandit H, Beard DJ, Carr AJ, Dawson J. The use of the Oxford hip and knee scores. J Bone Joint Surg Br. 2007;89:1010–1014.PubMed Murray DW, Fitzpatrick R, Rogers K, Pandit H, Beard DJ, Carr AJ, Dawson J. The use of the Oxford hip and knee scores. J Bone Joint Surg Br. 2007;89:1010–1014.PubMed
24.
go back to reference Onsten I, Besjakov J, Carlsson AS. Improved radiographic survival of the Charnley prosthesis in rheumatoid arthritis and osteoarthritis: results of new versus old operative techniques in 402 hips. J Arthroplasty. 1994;9:3–8.PubMedCrossRef Onsten I, Besjakov J, Carlsson AS. Improved radiographic survival of the Charnley prosthesis in rheumatoid arthritis and osteoarthritis: results of new versus old operative techniques in 402 hips. J Arthroplasty. 1994;9:3–8.PubMedCrossRef
25.
go back to reference Onsten I, Carlsson AS, Besjakov J. Wear in uncemented porous and cemented polyethylene sockets: a randomised, radiostereometric study. J Bone Joint Surg Br. 1998;80:345–350.PubMedCrossRef Onsten I, Carlsson AS, Besjakov J. Wear in uncemented porous and cemented polyethylene sockets: a randomised, radiostereometric study. J Bone Joint Surg Br. 1998;80:345–350.PubMedCrossRef
26.
go back to reference Ritter MA, Zhou H, Keating CM, Keating EM, Faris PM, Meding JB, Berend ME. Radiological factors influencing femoral and acetabular failure in cemented Charnley total hip arthroplasties. J Bone Joint Surg Br. 1999;81:982–986.PubMedCrossRef Ritter MA, Zhou H, Keating CM, Keating EM, Faris PM, Meding JB, Berend ME. Radiological factors influencing femoral and acetabular failure in cemented Charnley total hip arthroplasties. J Bone Joint Surg Br. 1999;81:982–986.PubMedCrossRef
27.
go back to reference Schmalzried TP, Kwong LM, Jasty M, Sedlacek RC, Haire TC, O’Connor DO, Bragdon CR, Kabo JM, Malcolm AJ, Harris WH. The mechanism of loosening of cemented acetabular components in total hip arthroplasty: analysis of specimens retrieved at autopsy. Clin Orthop Relat Res. 1992;274:60–78.PubMed Schmalzried TP, Kwong LM, Jasty M, Sedlacek RC, Haire TC, O’Connor DO, Bragdon CR, Kabo JM, Malcolm AJ, Harris WH. The mechanism of loosening of cemented acetabular components in total hip arthroplasty: analysis of specimens retrieved at autopsy. Clin Orthop Relat Res. 1992;274:60–78.PubMed
28.
go back to reference Söderkvist I, Wedin PA. Determining the movements of the skeleton using well-configured markers. J Biomech. 1993;26:1473–1477.PubMedCrossRef Söderkvist I, Wedin PA. Determining the movements of the skeleton using well-configured markers. J Biomech. 1993;26:1473–1477.PubMedCrossRef
29.
go back to reference Timperley AJ, Howell JR. Implant choice: rational for a flanged socket. In: Breusch SJ, Malchau H, eds. The Well-Cemented Total Hip Arthroplasty. Theory and Practice. Berlin, Germany: Springer; 2005:208–213.CrossRef Timperley AJ, Howell JR. Implant choice: rational for a flanged socket. In: Breusch SJ, Malchau H, eds. The Well-Cemented Total Hip Arthroplasty. Theory and Practice. Berlin, Germany: Springer; 2005:208–213.CrossRef
30.
go back to reference Valstar ER, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J. Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop. 2005;76:563–572.PubMed Valstar ER, Gill R, Ryd L, Flivik G, Borlin N, Karrholm J. Guidelines for standardization of radiostereometry (RSA) of implants. Acta Orthop. 2005;76:563–572.PubMed
Metadata
Title
The Influence of a Suction Device on Fixation of a Cemented Cup using RSA
Authors
A. John Timperley, DPhil
Sarah L. Whitehouse, PhD
Patrick G. Hourigan, MCSP
Publication date
01-03-2009
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 3/2009
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0574-z

Other articles of this Issue 3/2009

Clinical Orthopaedics and Related Research® 3/2009 Go to the issue

Symposium: Femoroacetabular Impingement: Current Status of Diagnosis and Treatment

Does Trochanteric Step Osteotomy Provide Greater Stability Than Classic Slide Osteotomy? A Preliminary Study

Symposium: Femoroacetabular Impingement: Current Status of Diagnosis and Treatment

Complications of Arthroscopic Femoroacetabular Impingement Treatment: A Review

Symposium: Femoroacetabular Impingement: Current Status of Diagnosis and Treatment

Labral Reconstruction Using the Ligamentum Teres Capitis: Report of a New Technique