Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 6/2009

01-06-2009 | Original Article

Early Experience with Biodegradable Implants in Pediatric Patients

Authors: Andreas F. Mavrogenis, MD, Anastasios D. Kanellopoulos, MD, George N. Nomikos, MD, Panayiotis J. Papagelopoulos, MD, DSc, Panayotis N. Soucacos, MD, FACS

Published in: Clinical Orthopaedics and Related Research® | Issue 6/2009

Login to get access

Abstract

We retrospectively studied nine children and adolescents with congenital malformations, large reconstruction after tumor excision, fractures and osteotomies of the upper extremity, and hand trauma with bone and soft tissue defects treated by internal synthesis using a biocopolymer of L- and DL-stereoisomers of lactic acid polymers and trimethylenecarbonate. A total of 52 biodegradable implants were placed in bone. At a minimum followup of 7 months (mean, 17 months; range, 7–22 months), wound healing was uncomplicated; local or systemic inflammatory tissue reactions, foreign body reactions, and infections were not observed. Bone healing was complete. Six biodegradable screws broke during insertion because of inadequate drilling and tapping, and three biodegradable screws had to be replaced because of damage to the screw head during assembly with the screwdriver. Biodegradable copolymers of poly-L-lactic-poly-DL-lactic acid and trimethylenecarbonate can be used safely and effectively for reconstruction and fixation of bone in children and adolescents.
Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Agins HJ, Alcock NW, Bansal M, Salvati EA, Wilson PD Jr, Pellicci PM, Bullough PG. Metallic wear in failed titanium-alloy total hip replacements: a histological and quantitative analysis. J Bone Joint Surg Am. 1988;70:347–356.PubMed Agins HJ, Alcock NW, Bansal M, Salvati EA, Wilson PD Jr, Pellicci PM, Bullough PG. Metallic wear in failed titanium-alloy total hip replacements: a histological and quantitative analysis. J Bone Joint Surg Am. 1988;70:347–356.PubMed
2.
go back to reference Ambrose CG, Clanton TO. Bioabsorbable implants: review of clinical experience in orthopedic surgery. Ann Biomed Eng. 2004;32:171–177.PubMedCrossRef Ambrose CG, Clanton TO. Bioabsorbable implants: review of clinical experience in orthopedic surgery. Ann Biomed Eng. 2004;32:171–177.PubMedCrossRef
3.
go back to reference Andriano KP, Pohjonen T, Tormala P. Processing and characterization of absorbable polylactide polymers for use in surgical implants. J Appl Biomater. 1994;5:133–140.PubMedCrossRef Andriano KP, Pohjonen T, Tormala P. Processing and characterization of absorbable polylactide polymers for use in surgical implants. J Appl Biomater. 1994;5:133–140.PubMedCrossRef
4.
go back to reference Bergsma JE, de Bruijn WC, Rozema FR, Bos RR, Boering G. Late degradation tissue response to poly(L-lactide) bone plates and screws. Biomaterials. 1995;16:25–31.PubMedCrossRef Bergsma JE, de Bruijn WC, Rozema FR, Bos RR, Boering G. Late degradation tissue response to poly(L-lactide) bone plates and screws. Biomaterials. 1995;16:25–31.PubMedCrossRef
5.
go back to reference Böstman OM. Absorbable implants for fracture fixation. J Bone Joint Surg Am. 1991;73:148–153.PubMed Böstman OM. Absorbable implants for fracture fixation. J Bone Joint Surg Am. 1991;73:148–153.PubMed
6.
go back to reference Böstman OM. Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg Br. 1991;73:679–682.PubMed Böstman OM. Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg Br. 1991;73:679–682.PubMed
7.
go back to reference Böstman OM. Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures. Clin Orthop Relat Res. 1992;278:193–198.PubMed Böstman OM. Intense granulomatous inflammatory lesions associated with absorbable internal fixation devices made of polyglycolide in ankle fractures. Clin Orthop Relat Res. 1992;278:193–198.PubMed
8.
go back to reference Böstman OM, Hirvensalo E, Mäkinen J, Rokkanen P. Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br. 1990;72:592–596.PubMed Böstman OM, Hirvensalo E, Mäkinen J, Rokkanen P. Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. J Bone Joint Surg Br. 1990;72:592–596.PubMed
9.
go back to reference Böstman OM, Mäkelä EA, Södergärd J, Hirvensalo E, Törmälä P, Rokkanen P. Absorbable polyglycolide pins in internal fixation of fractures in children. J Pediatr Orthop. 1993;13:242–245.PubMed Böstman OM, Mäkelä EA, Södergärd J, Hirvensalo E, Törmälä P, Rokkanen P. Absorbable polyglycolide pins in internal fixation of fractures in children. J Pediatr Orthop. 1993;13:242–245.PubMed
10.
go back to reference Böstman O, Pihlajamäki H. Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review. Biomaterials. 2000;21:2615–2621.PubMedCrossRef Böstman O, Pihlajamäki H. Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review. Biomaterials. 2000;21:2615–2621.PubMedCrossRef
11.
go back to reference Böstman OM, Pihlajamäki HK. Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop Relat Res. 2000;371:216–227.PubMedCrossRef Böstman OM, Pihlajamäki HK. Adverse tissue reactions to bioabsorbable fixation devices. Clin Orthop Relat Res. 2000;371:216–227.PubMedCrossRef
12.
go back to reference Brodke DS, Gollogly S, Alexander Mohr R, Nguyen BK, Dailey AT, Bachus AK. Dynamic cervical plates: biomechanical evaluation of load sharing and stiffness. Spine. 2001;26:1324–1329.PubMedCrossRef Brodke DS, Gollogly S, Alexander Mohr R, Nguyen BK, Dailey AT, Bachus AK. Dynamic cervical plates: biomechanical evaluation of load sharing and stiffness. Spine. 2001;26:1324–1329.PubMedCrossRef
13.
go back to reference Bucholz RW, Henry S, Henley MB. Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J Bone Joint Surg Am. 1994;76:319–324.PubMed Bucholz RW, Henry S, Henley MB. Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J Bone Joint Surg Am. 1994;76:319–324.PubMed
14.
go back to reference Ciccone WJ 2nd, Motz C, Bentley C, Tasto JP. Bioabsorbable implants in orthopaedics: new developments and clinical applications. J Am Acad Orthop Surg. 2001;9:280–288.PubMed Ciccone WJ 2nd, Motz C, Bentley C, Tasto JP. Bioabsorbable implants in orthopaedics: new developments and clinical applications. J Am Acad Orthop Surg. 2001;9:280–288.PubMed
15.
16.
go back to reference Cordewener FW, Schmitz JP. The future of biodegradable osteosyntheses. Tissue Eng. 2000;6:413–424.PubMedCrossRef Cordewener FW, Schmitz JP. The future of biodegradable osteosyntheses. Tissue Eng. 2000;6:413–424.PubMedCrossRef
17.
go back to reference El-Amin SF, Attawia M, Lu HH, Shah AK, Chang R, Hickok NJ, Tuan RS, Laurencin CT. Integrin expression by human osteoblasts cultured on degradable polymeric materials applicable for tissue engineered bone. J Orthop Res. 2002;20:20–28.PubMedCrossRef El-Amin SF, Attawia M, Lu HH, Shah AK, Chang R, Hickok NJ, Tuan RS, Laurencin CT. Integrin expression by human osteoblasts cultured on degradable polymeric materials applicable for tissue engineered bone. J Orthop Res. 2002;20:20–28.PubMedCrossRef
18.
go back to reference Hollinger JO, Battistone GC. Biodegradable bone repair materials: synthetic polymers and ceramics. Clin Orthop Relat Res. 1986;207:290–305.PubMed Hollinger JO, Battistone GC. Biodegradable bone repair materials: synthetic polymers and ceramics. Clin Orthop Relat Res. 1986;207:290–305.PubMed
19.
go back to reference Jorgenson DS, Mayer MH, Ellenbogen RG, Centeno JA, Johnson FB, Mullick FG, Manson PN. Detection of titanium in human tissues after craniofacial surgery. Plast Reconstr Surg. 1997;99:976–981.PubMedCrossRef Jorgenson DS, Mayer MH, Ellenbogen RG, Centeno JA, Johnson FB, Mullick FG, Manson PN. Detection of titanium in human tissues after craniofacial surgery. Plast Reconstr Surg. 1997;99:976–981.PubMedCrossRef
20.
go back to reference Kim YK, Yeo HH, Lim SC. Tissue response to titanium plates: a transmitted electron microscopic study. J Oral Maxillofac Surg. 1997;55:322–326.PubMedCrossRef Kim YK, Yeo HH, Lim SC. Tissue response to titanium plates: a transmitted electron microscopic study. J Oral Maxillofac Surg. 1997;55:322–326.PubMedCrossRef
21.
go back to reference Kulkarni RK, Pani KC, Neuman C, Leonard F. Polylactic acid for surgical implants. Arch Surg. 1966;93:839–843.PubMed Kulkarni RK, Pani KC, Neuman C, Leonard F. Polylactic acid for surgical implants. Arch Surg. 1966;93:839–843.PubMed
22.
go back to reference Liu JG, Ma WH, Xu XX. Orthopaedic applications for biodegradable and absorbable internal fixation of fractures. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2002;16:209–211.PubMed Liu JG, Ma WH, Xu XX. Orthopaedic applications for biodegradable and absorbable internal fixation of fractures. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2002;16:209–211.PubMed
23.
go back to reference Mäkelä EA, Böstman O, Kekomäki M, Södergård J, Vainio J, Törmälä P, Rokkanen P. Biodegradable fixation of distal humeral physeal fractures. Clin Orthop Relat Res. 1992;283:237–243.PubMed Mäkelä EA, Böstman O, Kekomäki M, Södergård J, Vainio J, Törmälä P, Rokkanen P. Biodegradable fixation of distal humeral physeal fractures. Clin Orthop Relat Res. 1992;283:237–243.PubMed
24.
go back to reference Mäkelä EA, Vainionpää S, Vihtonen K, Mero M, Helevirta P, Törmälä P, Rokkanen P. The effect of a penetrating biodegradable implant on the growth plate: an experimental study on growing rabbits with special reference to polydioxanone. Clin Orthop Relat Res. 1989;241:300–308.PubMed Mäkelä EA, Vainionpää S, Vihtonen K, Mero M, Helevirta P, Törmälä P, Rokkanen P. The effect of a penetrating biodegradable implant on the growth plate: an experimental study on growing rabbits with special reference to polydioxanone. Clin Orthop Relat Res. 1989;241:300–308.PubMed
25.
go back to reference Middleton JC, Tipton AJ. Synthetic biodegradable polymers as orthopaedic devices. Biomaterials. 2000;21:2335–2346.PubMedCrossRef Middleton JC, Tipton AJ. Synthetic biodegradable polymers as orthopaedic devices. Biomaterials. 2000;21:2335–2346.PubMedCrossRef
26.
go back to reference Mittal R, Morley J, Dinopoulos H, Drakoulakis EG, Vermani E, Giannoudis PV. Use of bio-resorbable implants for stabilisation of distal radius fractures: the United Kingdom patients’ perspective. Injury. 2005;36:333–338.PubMedCrossRef Mittal R, Morley J, Dinopoulos H, Drakoulakis EG, Vermani E, Giannoudis PV. Use of bio-resorbable implants for stabilisation of distal radius fractures: the United Kingdom patients’ perspective. Injury. 2005;36:333–338.PubMedCrossRef
27.
go back to reference Orringer JS, Barcelona V, Buchman SR. Reasons for removal of rigid internal fixation devices in craniofacial surgery. J Craniofac Surg. 1998;9:40–44.PubMedCrossRef Orringer JS, Barcelona V, Buchman SR. Reasons for removal of rigid internal fixation devices in craniofacial surgery. J Craniofac Surg. 1998;9:40–44.PubMedCrossRef
28.
go back to reference Papagelopoulos PJ, Giannarakos DG, Lyritis GP. Suitability of biodegradable polydioxanone materials for the internal fixation of fractures. Orthop Rev. 1993;22:585–593.PubMed Papagelopoulos PJ, Giannarakos DG, Lyritis GP. Suitability of biodegradable polydioxanone materials for the internal fixation of fractures. Orthop Rev. 1993;22:585–593.PubMed
29.
go back to reference Pietrzak WS, Sarver DR, Verstynen ML. Bioabsorbable polymer science for the practicing surgeon. J Craniofac Surg. 1997;8:87–91.PubMed Pietrzak WS, Sarver DR, Verstynen ML. Bioabsorbable polymer science for the practicing surgeon. J Craniofac Surg. 1997;8:87–91.PubMed
30.
go back to reference Raghoebar GM, Liem RS, Bos RR, van der Wal JE, Vissink A. Resorbable screws for fixation of autologous bone grafts. Clin Oral Implants Res. 2006;17:288–293.PubMedCrossRef Raghoebar GM, Liem RS, Bos RR, van der Wal JE, Vissink A. Resorbable screws for fixation of autologous bone grafts. Clin Oral Implants Res. 2006;17:288–293.PubMedCrossRef
31.
go back to reference Rokkanen P, Böstman O, Vainionpää S, Mäkelä EA, Hirvensalo E, Partio EK, Vihtonen K, Pätiälä H, Törmälä P. Absorbable devices in the fixation of fractures. J Trauma. 1996;40(suppl):S123–S127. Rokkanen P, Böstman O, Vainionpää S, Mäkelä EA, Hirvensalo E, Partio EK, Vihtonen K, Pätiälä H, Törmälä P. Absorbable devices in the fixation of fractures. J Trauma. 1996;40(suppl):S123–S127.
32.
go back to reference Rokkanen PU, Böstman O, Hirvensalo E, Mäkelä EA, Partio EK, Pätiälä H, Vainionpää S, Vihtonen K, Törmälä P. Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials. 2000;21:2607–2613.PubMedCrossRef Rokkanen PU, Böstman O, Hirvensalo E, Mäkelä EA, Partio EK, Pätiälä H, Vainionpää S, Vihtonen K, Törmälä P. Bioabsorbable fixation in orthopaedic surgery and traumatology. Biomaterials. 2000;21:2607–2613.PubMedCrossRef
33.
go back to reference Schmidt BL, Perrott DH, Mahan D, Kearns G. The removal of plates and screws after Le Fort I osteotomy. J Oral Maxillofac Surg. 1998;56:184–188.PubMedCrossRef Schmidt BL, Perrott DH, Mahan D, Kearns G. The removal of plates and screws after Le Fort I osteotomy. J Oral Maxillofac Surg. 1998;56:184–188.PubMedCrossRef
34.
go back to reference Sinisaari I, Pätiälä H, Böstman O, Mäkelä EA, Hirvensalo E, Partio EK, Törmälä P, Rokkanen P. Wound infections associated with absorbable or metallic devices used in the fixation of fractures, arthrodeses, and osteotomies. Eur J Orthop Surg Traumatol. 1995;5:41–43.CrossRef Sinisaari I, Pätiälä H, Böstman O, Mäkelä EA, Hirvensalo E, Partio EK, Törmälä P, Rokkanen P. Wound infections associated with absorbable or metallic devices used in the fixation of fractures, arthrodeses, and osteotomies. Eur J Orthop Surg Traumatol. 1995;5:41–43.CrossRef
35.
go back to reference Stendel R, Krischek B, Pietila TA. Biodegradable implants in neurosurgery. Acta Neurochir (Wien). 2001;143:237–243.CrossRef Stendel R, Krischek B, Pietila TA. Biodegradable implants in neurosurgery. Acta Neurochir (Wien). 2001;143:237–243.CrossRef
36.
go back to reference Sullivan PK, Smith JF, Rozzelle AA. Cranio-orbital reconstruction: safety and image quality of metallic implants on CT and MRI scanning. Plast Reconstr Surg. 1994;94:589–596.PubMedCrossRef Sullivan PK, Smith JF, Rozzelle AA. Cranio-orbital reconstruction: safety and image quality of metallic implants on CT and MRI scanning. Plast Reconstr Surg. 1994;94:589–596.PubMedCrossRef
37.
go back to reference Toro C, Robiony M, Zerman N, Politi M. Resorbable plates in maxillary fixation: a 5-year experience. Minerva Stomatol. 2005;54:199–206.PubMed Toro C, Robiony M, Zerman N, Politi M. Resorbable plates in maxillary fixation: a 5-year experience. Minerva Stomatol. 2005;54:199–206.PubMed
38.
go back to reference Vaccaro AR, Singh K, Haid R, Kitchel S, Wuisman P, Taylor W, Branch C, Garfin S. The use of bioabsorbable implants in the spine. Spine J. 2003;3:227–237.PubMedCrossRef Vaccaro AR, Singh K, Haid R, Kitchel S, Wuisman P, Taylor W, Branch C, Garfin S. The use of bioabsorbable implants in the spine. Spine J. 2003;3:227–237.PubMedCrossRef
39.
go back to reference Wu HC, Shen FW, Hong X, Chang WV, Winet H. Monitoring the degradation process of biopolymers by ultrasonic longitudinal wave pulse-echo technique. Biomaterials. 2003;24:3871–3876.PubMedCrossRef Wu HC, Shen FW, Hong X, Chang WV, Winet H. Monitoring the degradation process of biopolymers by ultrasonic longitudinal wave pulse-echo technique. Biomaterials. 2003;24:3871–3876.PubMedCrossRef
40.
go back to reference Yaremchuk MJ, Fiala TG, Barker F, Ragland R. The effects of rigid fixation on craniofacial growth of rhesus monkeys. Plast Reconstr Surg. 1994;93:1–15.PubMedCrossRef Yaremchuk MJ, Fiala TG, Barker F, Ragland R. The effects of rigid fixation on craniofacial growth of rhesus monkeys. Plast Reconstr Surg. 1994;93:1–15.PubMedCrossRef
Metadata
Title
Early Experience with Biodegradable Implants in Pediatric Patients
Authors
Andreas F. Mavrogenis, MD
Anastasios D. Kanellopoulos, MD
George N. Nomikos, MD
Panayiotis J. Papagelopoulos, MD, DSc
Panayotis N. Soucacos, MD, FACS
Publication date
01-06-2009
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 6/2009
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0537-4

Other articles of this Issue 6/2009

Clinical Orthopaedics and Related Research® 6/2009 Go to the issue

Symposium: Advanced Techniques for Rehabilitation after Total Hip and Knee Arthroplasty

Comparison of Outpatient versus Inpatient Total Knee Arthroplasty

Symposium: Advanced Techniques for Rehabilitation after Total Hip and Knee Arthroplasty

THA with a Minimally Invasive Technique, Multi-modal Anesthesia, and Home Rehabilitation: Factors Associated with Early Discharge?