Skip to main content
Top
Published in: Journal of Children's Orthopaedics 1/2015

Open Access 01-02-2015 | Original Clinical Article

Local and systemic metal ion release occurs intraoperatively during correction and instrumented spinal fusion for scoliosis

Authors: William J. Cundy, Annika R. Mascarenhas, Georgia Antoniou, Brian J. C. Freeman, Peter J. Cundy

Published in: Journal of Children's Orthopaedics | Issue 1/2015

Login to get access

Abstract

Study design

Prospective pilot study.

Objectives

The aim of this study was to measure titanium, niobium and aluminium levels in various intraoperative and postoperative samples to determine patterns of metal ion release that occur within the first month following instrumented spinal fusion.

Summary of background data

Raised serum metal ion levels are reported following instrumented spinal fusion in adolescent idiopathic scoliosis. The exact topological origin and chronology of metal ion release remains conjectural. Recent literature suggests an immediate rise in serum metal levels within the first postoperative week.

Methods

Titanium, niobium and aluminium levels were measured before, during and after surgery in serum and local intraoperative fluid samples obtained from two pediatric patients undergoing posterior correction and instrumentation for scoliosis.

Results

Measurable metal ion levels were detected in all local samples obtained from wound irrigation fluid, cell saver blood, and fluid that immersed metal universal reduction screw tabs. Postoperative serum metal ion levels were elevated compared to baseline preoperative levels. In general, metal ion levels were considerably higher in the intraoperative fluid samples compared to those observed in the serum levels.

Conclusion

Our findings of contextually high metal ion concentrations in intraoperative and early postoperative samples provide further empirical support of a ‘putting-in’ phenomenon of metal ion release following instrumented spinal fusion. This challenges existing beliefs that metal ion release occurs during an intermediate ‘wearing-in’ phase. We recommend thorough irrigation of the operative site prior to wound closure to dilute and remove intraoperative metal ion debris. Possibilities of filtering trace metal ions from cell saver content may be considered.
Literature
2.
6.
go back to reference Hallab NJ, Cunningham BW, Jacobs JJ (2003) Spinal implant debris-induced osteolysis. Spine 28(20):S125–S138PubMedCrossRef Hallab NJ, Cunningham BW, Jacobs JJ (2003) Spinal implant debris-induced osteolysis. Spine 28(20):S125–S138PubMedCrossRef
7.
go back to reference Cunningham BW, Orbegoso CM, Dmitriev AE, Hallab NJ, Sefter JC, McAfee PC (2002) The effect of titanium particulate on development and maintenance of a posterolateral spinal arthrodesis: an in vivo rabbit model. Spine 27(18):1971–1981PubMedCrossRef Cunningham BW, Orbegoso CM, Dmitriev AE, Hallab NJ, Sefter JC, McAfee PC (2002) The effect of titanium particulate on development and maintenance of a posterolateral spinal arthrodesis: an in vivo rabbit model. Spine 27(18):1971–1981PubMedCrossRef
8.
go back to reference Wang JC, Yu WD, Sandhu HS, Betts F, Bhuta S, Delamarter RB (1999) Metal debris from titanium spinal implants. Spine 24(9):899–903PubMedCrossRef Wang JC, Yu WD, Sandhu HS, Betts F, Bhuta S, Delamarter RB (1999) Metal debris from titanium spinal implants. Spine 24(9):899–903PubMedCrossRef
9.
go back to reference Haynes DR, Boyle SJ, Rogers SD, Howie DW, Vernon-Roberts B (1998) Variation in cytokines induced by particles from different prosthetic materials. Clin Orthop Relat Res 352:223–230PubMed Haynes DR, Boyle SJ, Rogers SD, Howie DW, Vernon-Roberts B (1998) Variation in cytokines induced by particles from different prosthetic materials. Clin Orthop Relat Res 352:223–230PubMed
10.
go back to reference Haynes DR, Rogers SD, Hay S, Pearcy MJ, Howie DW (1993) The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt–chromium-alloy wear particles. J Bone Joint Surg Am 75(6):825–834PubMed Haynes DR, Rogers SD, Hay S, Pearcy MJ, Howie DW (1993) The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt–chromium-alloy wear particles. J Bone Joint Surg Am 75(6):825–834PubMed
11.
go back to reference Urban RM, Jacobs JJ, Tomlinson MJ, Gavrilovic J, Black J, Peoc’h M (2000) Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J Bone Joint Surg Am 82(4):457–476PubMed Urban RM, Jacobs JJ, Tomlinson MJ, Gavrilovic J, Black J, Peoc’h M (2000) Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J Bone Joint Surg Am 82(4):457–476PubMed
12.
go back to reference Jacobs JJ, Skipor AK, Black J, Urban R, Galante JO (1991) Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy. J Bone Joint Surg Am 73(10):1475–1486PubMed Jacobs JJ, Skipor AK, Black J, Urban R, Galante JO (1991) Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy. J Bone Joint Surg Am 73(10):1475–1486PubMed
13.
go back to reference Denaro V, Papapietro N, Sgambato A, Barnaba SA, Ruzzini L, Paola BD, Rettino A, Cittadini A (2008) Periprosthetic electrochemical corrosion of titanium and titanium-based alloys as a cause of spinal fusion failure. Spine 33(1):8–13. doi:10.1097/BRS.0b013e31815e3978PubMedCrossRef Denaro V, Papapietro N, Sgambato A, Barnaba SA, Ruzzini L, Paola BD, Rettino A, Cittadini A (2008) Periprosthetic electrochemical corrosion of titanium and titanium-based alloys as a cause of spinal fusion failure. Spine 33(1):8–13. doi:10.​1097/​BRS.​0b013e31815e3978​PubMedCrossRef
18.
go back to reference Krischak GD, Gebhard F, Mohr W, Krivan V, Ignatius A, Beck A, Wachter NJ, Reuter P, Arand M, Kinzl L, Claes LE (2004) Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates. Arch Orthop Trauma Surg 124(2):104–113. doi:10.1007/s00402-003-0614-9PubMedCrossRef Krischak GD, Gebhard F, Mohr W, Krivan V, Ignatius A, Beck A, Wachter NJ, Reuter P, Arand M, Kinzl L, Claes LE (2004) Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates. Arch Orthop Trauma Surg 124(2):104–113. doi:10.​1007/​s00402-003-0614-9PubMedCrossRef
Metadata
Title
Local and systemic metal ion release occurs intraoperatively during correction and instrumented spinal fusion for scoliosis
Authors
William J. Cundy
Annika R. Mascarenhas
Georgia Antoniou
Brian J. C. Freeman
Peter J. Cundy
Publication date
01-02-2015
Publisher
Springer Berlin Heidelberg
Published in
Journal of Children's Orthopaedics / Issue 1/2015
Print ISSN: 1863-2521
Electronic ISSN: 1863-2548
DOI
https://doi.org/10.1007/s11832-015-0631-6

Other articles of this Issue 1/2015

Journal of Children's Orthopaedics 1/2015 Go to the issue