Skip to main content
Top
Published in: Journal of Children's Orthopaedics 6/2013

01-12-2013 | Original Clinical Article

Airport metal detector activation is rare after posterior spinal fusion in children with scoliosis

Authors: Peter D. Fabricant, Alex Robles, John S. Blanco

Published in: Journal of Children's Orthopaedics | Issue 6/2013

Login to get access

Abstract

Purpose

Since the September 11, 2001 terrorist attacks on the World Trade Center in New York City, travel security has become an ever-increasing priority in the United States. Frequent parent and patient inquiry and recent literature reports have generated interest in the impact of heightened security measures on patients with orthopaedic implants, and have indicated increasing rates of metal detector triggering. There are no reports to date, however, evaluating children and adolescents who have undergone posterior spinal fusion for scoliosis, so responses to patient and parent inquiries are not data-driven. The purpose of this study is to determine the frequency of airport metal detector triggering by patients who have had posterior-only spinal fusion and to characterise any potential predictors of metal detector activation.

Methods

A cross-sectional study was performed by interviewing 90 patients who underwent posterior-only spinal fusion for a diagnosis of juvenile or adolescent idiopathic scoliosis and have travelled by air in the past year. Demographic, clinical and surgical instrumentation data were collected and evaluated, along with patients’ reports of airport metal detector triggering and subsequent screening procedures.

Results

Five patients with stainless steel instrumentation (5.6 % of the cohort) triggered an airport walkthrough metal detector, and an additional five patients who did not trigger an airport detector triggered a handheld detector at a different venue. All patients who triggered an airport metal detector had stainless steel instrumentation implanted prior to 2008, and no patient with titanium instrumentation triggered any detector in any venue. All trigger events required subsequent screening procedures, even when an implant card was presented.

Conclusions

In this cohort of children and adolescents with posterior spinal instrumentation, airport walkthrough metal detector triggering was a rare event. Therefore, we advise patients and families with planned posterior scoliosis fusions using titanium instrumentation that airport detection risk is essentially non-existent, and only rare for those with planned stainless steel instrumentation. We no longer issue implant cards postoperatively, as these did not prevent further screening procedures in this cohort.

Level of evidence

Prognostic level 2. Study design: cross-sectional.
Literature
1.
go back to reference Basu P, Packer GJ, Himstedt J (1997) Detection of orthopaedic implants by airport metal detectors. J Bone Joint Surg Br 79:388–389PubMedCrossRef Basu P, Packer GJ, Himstedt J (1997) Detection of orthopaedic implants by airport metal detectors. J Bone Joint Surg Br 79:388–389PubMedCrossRef
2.
go back to reference Grohs JG, Gottsauner-Wolf F (1997) Detection of orthopaedic prostheses at airport security checks. J Bone Joint Surg Br 79:385–387PubMedCrossRef Grohs JG, Gottsauner-Wolf F (1997) Detection of orthopaedic prostheses at airport security checks. J Bone Joint Surg Br 79:385–387PubMedCrossRef
3.
go back to reference van Rhijn LW, Veraart BE (1994) Metal detectors for security checks mostly insensitive for metal implants. Ned Tijdschr Geneeskd 138:825–827PubMed van Rhijn LW, Veraart BE (1994) Metal detectors for security checks mostly insensitive for metal implants. Ned Tijdschr Geneeskd 138:825–827PubMed
6.
go back to reference Johnson AJ, Naziri Q, Hooper HA, Mont MA (2012) Detection of total hip prostheses at airport security checkpoints: how has heightened security affected patients? J Bone Joint Surg Am 94:e44. doi:10.2106/JBJS.K.00864PubMed Johnson AJ, Naziri Q, Hooper HA, Mont MA (2012) Detection of total hip prostheses at airport security checkpoints: how has heightened security affected patients? J Bone Joint Surg Am 94:e44. doi:10.​2106/​JBJS.​K.​00864PubMed
9.
10.
go back to reference Kamineni S, Legge S, Ware H (2002) Metallic orthopaedic implants and airport metal detectors. J Arthroplasty 17:62–65PubMedCrossRef Kamineni S, Legge S, Ware H (2002) Metallic orthopaedic implants and airport metal detectors. J Arthroplasty 17:62–65PubMedCrossRef
11.
go back to reference Kocher MS, Zurakowski D (2004) Clinical epidemiology and biostatistics: a primer for orthopaedic surgeons. J Bone Joint Surg Am 86-A:607–620PubMed Kocher MS, Zurakowski D (2004) Clinical epidemiology and biostatistics: a primer for orthopaedic surgeons. J Bone Joint Surg Am 86-A:607–620PubMed
12.
go back to reference Emsley J (2001) Titanium. In: Nature’s building blocks: an A–Z guide to the elements. Oxford University Press, Oxford, p 452 Emsley J (2001) Titanium. In: Nature’s building blocks: an A–Z guide to the elements. Oxford University Press, Oxford, p 452
13.
go back to reference Transportation Security Administration (TSA) (2012) Notification Card 2012 Transportation Security Administration (TSA) (2012) Notification Card 2012
14.
go back to reference Transportation Security Administration (TSA) (2012) Advanced Imaging Technology (AIT) 2012 Transportation Security Administration (TSA) (2012) Advanced Imaging Technology (AIT) 2012
Metadata
Title
Airport metal detector activation is rare after posterior spinal fusion in children with scoliosis
Authors
Peter D. Fabricant
Alex Robles
John S. Blanco
Publication date
01-12-2013
Publisher
Springer Berlin Heidelberg
Published in
Journal of Children's Orthopaedics / Issue 6/2013
Print ISSN: 1863-2521
Electronic ISSN: 1863-2548
DOI
https://doi.org/10.1007/s11832-013-0527-2

Other articles of this Issue 6/2013

Journal of Children's Orthopaedics 6/2013 Go to the issue