Skip to main content
Top
Published in: Strategies in Trauma and Limb Reconstruction 2/2017

Open Access 01-08-2017 | Review

Three-dimensional virtual planning of corrective osteotomies of distal radius malunions: a systematic review and meta-analysis

Authors: R. J. O. de Muinck Keizer, K. M. Lechner, M. A. M. Mulders, N. W. L. Schep, D. Eygendaal, J. C. Goslings

Published in: Strategies in Trauma and Limb Reconstruction | Issue 2/2017

Login to get access

Abstract

The purpose of this study was to summarize and evaluate results of three-dimensional (3D-) planned corrective osteotomies of malunited distal radius fractures. 3D-planning techniques provide the possibility to address 3D-deformity that conventional planning methods might not address. We systematically searched PubMed, EMBASE and the Cochrane library for studies that performed a 3D-planned corrective osteotomy on patients with a malunited distal radius fracture. Fifteen studies with a total of 68 patients were included in the analysis. In 96% of cases, the preoperatively present palmar tilt, radial inclination and ulnar variance showed statistically significant improvement postoperatively with restoration to within 5° or 2 mm of their normal values. Mean flexion–extension, pro-supination and grip strength showed statistically significant improvement (p < 0.05). Complications were reported in 11 out of 68 patients (16%). With the current advances in 3D printing technology, 3D-planned corrective osteotomies seem a promising technique in the treatment of complex distal radius malunions.
Level of evidence IV Systematic review of case series, Level IV.
Appendix
Available only for authorised users
Literature
1.
go back to reference Cooney WP, Dobyns JH, Linscheid RL (1980) Complications of Colles’ fractures. J Bone Jt Surg Am 62:613–619CrossRef Cooney WP, Dobyns JH, Linscheid RL (1980) Complications of Colles’ fractures. J Bone Jt Surg Am 62:613–619CrossRef
2.
3.
go back to reference Graham T (1997) Surgical correction of malunited fractures of the distal radius. J Am Acad Orthop Surg 5:270–281CrossRefPubMed Graham T (1997) Surgical correction of malunited fractures of the distal radius. J Am Acad Orthop Surg 5:270–281CrossRefPubMed
4.
go back to reference Slagel B, Luenam S, Pichora D (2010) Management of post-traumatic malunion of fractures of the distal radius. Hand Clin 26:71–84CrossRefPubMed Slagel B, Luenam S, Pichora D (2010) Management of post-traumatic malunion of fractures of the distal radius. Hand Clin 26:71–84CrossRefPubMed
6.
go back to reference Gartland J, Werley C (1951) Evaluation of healed Colles’ fractures. J Bone Jt Surg Am 33-A:895–907CrossRef Gartland J, Werley C (1951) Evaluation of healed Colles’ fractures. J Bone Jt Surg Am 33-A:895–907CrossRef
7.
go back to reference Nana A, Joshi A, Lichtman D (2005) Plating of the distal radius. Acad Ortho Surg 13:159–171CrossRef Nana A, Joshi A, Lichtman D (2005) Plating of the distal radius. Acad Ortho Surg 13:159–171CrossRef
8.
go back to reference Prommersberger K, Pillukat T, Muhldorfer M, Sch V (2012) Malunion of the distal radius. J Am Acad Orthop Surg 132:693–702 Prommersberger K, Pillukat T, Muhldorfer M, Sch V (2012) Malunion of the distal radius. J Am Acad Orthop Surg 132:693–702
10.
go back to reference Ladd A, Huene D (1996) Reconstructive osteotomy for malunion of the distal radius. Clin Orthop Relat Res 327:158–171CrossRef Ladd A, Huene D (1996) Reconstructive osteotomy for malunion of the distal radius. Clin Orthop Relat Res 327:158–171CrossRef
13.
go back to reference Prommersberger KJ, van Schoonhoven J, Lanz UB (2002) Outcome after corrective osteotomy for malunited fractures of the distal end of the radius. J Hand Surg Am 27B:55–60CrossRef Prommersberger KJ, van Schoonhoven J, Lanz UB (2002) Outcome after corrective osteotomy for malunited fractures of the distal end of the radius. J Hand Surg Am 27B:55–60CrossRef
16.
go back to reference Oka K, Murase T, Moritomo H et al (2010) Corrective osteotomy using customized hydrozyapatite implants prepared by preoperative computer simulation. Int J Med Robot 6:186–193. doi:10.1002/rcs PubMed Oka K, Murase T, Moritomo H et al (2010) Corrective osteotomy using customized hydrozyapatite implants prepared by preoperative computer simulation. Int J Med Robot 6:186–193. doi:10.​1002/​rcs PubMed
20.
22.
go back to reference Murase T, Oka K, Moritomo H et al (2008) Three-dimensional corrective osteotomy of malunited fractures of the upper extremity with use of a computer simulation system. J Bone Joint Surg Am 90:2375–2389. doi:10.2106/JBJS.G.01299 CrossRefPubMed Murase T, Oka K, Moritomo H et al (2008) Three-dimensional corrective osteotomy of malunited fractures of the upper extremity with use of a computer simulation system. J Bone Joint Surg Am 90:2375–2389. doi:10.​2106/​JBJS.​G.​01299 CrossRefPubMed
27.
go back to reference Walenkamp MMJ, de Muinck Keizer RJO, Dobbe JGG et al (2015) Computer-assisted 3D planned corrective osteotomies in eight malunited radius fractures. Strateg Trauma Limb Reconstr 10:109–116. doi:10.1007/s11751-015-0234-2 CrossRef Walenkamp MMJ, de Muinck Keizer RJO, Dobbe JGG et al (2015) Computer-assisted 3D planned corrective osteotomies in eight malunited radius fractures. Strateg Trauma Limb Reconstr 10:109–116. doi:10.​1007/​s11751-015-0234-2 CrossRef
28.
go back to reference Croitoru H, Ellis RE, Prihar R (2001) Fixation-based surgery: a new technique for distal radius osteotomy. Comput Aided Surg 6:160–169CrossRefPubMed Croitoru H, Ellis RE, Prihar R (2001) Fixation-based surgery: a new technique for distal radius osteotomy. Comput Aided Surg 6:160–169CrossRefPubMed
30.
go back to reference Dobbe JGG, Vroemen JC, Strackee SD, Streekstra GJ (2014) Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy. Strateg Trauma Limb Reconstr 9:179–183. doi:10.1007/s11751-014-0203-1 CrossRef Dobbe JGG, Vroemen JC, Strackee SD, Streekstra GJ (2014) Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy. Strateg Trauma Limb Reconstr 9:179–183. doi:10.​1007/​s11751-014-0203-1 CrossRef
31.
go back to reference Oka K, Moritomo H, Goto A et al (2008) Corrective osteotomy for malunited intra-articular fracture of the distal radius using a custom-made surgical guide based on three-dimensional computer simulation: case report. J Hand Surg Am 33:835–840. doi:10.1016/j.jhsa.2008.02.008 CrossRefPubMed Oka K, Moritomo H, Goto A et al (2008) Corrective osteotomy for malunited intra-articular fracture of the distal radius using a custom-made surgical guide based on three-dimensional computer simulation: case report. J Hand Surg Am 33:835–840. doi:10.​1016/​j.​jhsa.​2008.​02.​008 CrossRefPubMed
34.
go back to reference Zimmermann R, Gabl M, Arora R, Rieger M (2003) Computerassistierte Planung und Korrekturosteotomie nach fehlverheilter distaler Radiusfraktur. Handchir Mikrochir Plast Chir 35:333–337. doi:10.1055/s-2003-43115 CrossRefPubMed Zimmermann R, Gabl M, Arora R, Rieger M (2003) Computerassistierte Planung und Korrekturosteotomie nach fehlverheilter distaler Radiusfraktur. Handchir Mikrochir Plast Chir 35:333–337. doi:10.​1055/​s-2003-43115 CrossRefPubMed
35.
go back to reference Miyake J, Murase T, Yamanaka Y et al (2012) Three-dimensional deformity analysis of malunited distal radius fractures and their influence on wrist and forearm motion. J Hand Surg Eur 37:506–512. doi:10.1177/1753193412443644 CrossRef Miyake J, Murase T, Yamanaka Y et al (2012) Three-dimensional deformity analysis of malunited distal radius fractures and their influence on wrist and forearm motion. J Hand Surg Eur 37:506–512. doi:10.​1177/​1753193412443644​ CrossRef
36.
go back to reference Moher D, Liberati A, Tetzlaff J et al (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement (reprinted from annals of internal medicine). Phys Ther 89:873–880. doi:10.1371/journal.pmed.1000097 PubMed Moher D, Liberati A, Tetzlaff J et al (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement (reprinted from annals of internal medicine). Phys Ther 89:873–880. doi:10.​1371/​journal.​pmed.​1000097 PubMed
37.
go back to reference Moga C, Guo B, Schopflocher D, Harstall C (2012) Development of a quality appraisal tool for case series studies using a modified Delphi technique. Edmonton, Institute of Health Economics (IHE) Moga C, Guo B, Schopflocher D, Harstall C (2012) Development of a quality appraisal tool for case series studies using a modified Delphi technique. Edmonton, Institute of Health Economics (IHE)
38.
go back to reference Stewart LA, Tierney JF (2002) To IPD or not to IPD? Advantages and disadvantages of systematic reviews using individual patient data. Eval Health Prof 25:76–97CrossRefPubMed Stewart LA, Tierney JF (2002) To IPD or not to IPD? Advantages and disadvantages of systematic reviews using individual patient data. Eval Health Prof 25:76–97CrossRefPubMed
41.
go back to reference Weihrauch M, Bickert B, Germann G, Sauerbier M (2006) Functional outcome after corrective osteotomy of the distal radius. Unfallchirurg 109:93–100CrossRefPubMed Weihrauch M, Bickert B, Germann G, Sauerbier M (2006) Functional outcome after corrective osteotomy of the distal radius. Unfallchirurg 109:93–100CrossRefPubMed
Metadata
Title
Three-dimensional virtual planning of corrective osteotomies of distal radius malunions: a systematic review and meta-analysis
Authors
R. J. O. de Muinck Keizer
K. M. Lechner
M. A. M. Mulders
N. W. L. Schep
D. Eygendaal
J. C. Goslings
Publication date
01-08-2017
Publisher
Springer Milan
Published in
Strategies in Trauma and Limb Reconstruction / Issue 2/2017
Print ISSN: 1828-8936
Electronic ISSN: 1828-8928
DOI
https://doi.org/10.1007/s11751-017-0284-8

Other articles of this Issue 2/2017

Strategies in Trauma and Limb Reconstruction 2/2017 Go to the issue