Skip to main content
Top
Published in: General Thoracic and Cardiovascular Surgery 6/2019

01-06-2019 | Case Report

Anatomical correction of atrioventricular discordance using three-dimensional replica

Authors: Tai Fuchigami, Masahiko Nishioka, Toru Akashige, Mami Nakayashiro, Nobuhiro Nagata

Published in: General Thoracic and Cardiovascular Surgery | Issue 6/2019

Login to get access

Abstract

Surgical experience with {S,L,D} segmental anatomy of atrioventricular discordance with double-outlet right ventricle is extremely rare. In addition to ordinary cardiac examination, we reviewed electrophysiological studies and a three-dimensional cardiac replica (crossMedical, Inc., Kyoto, Japan). Consequently, we preoperatively confirmed the intracardiac rerouting line and the appropriate right ventricle incision line. A Senning procedure, intracardiac rerouting, and subaortic stenosis resection were performed in a 2.6-year-old patient (weight, 10.6 kg). The three-dimensional cardiac replica contributed definitively to the anatomical correction.
Literature
1.
go back to reference Fuchigami T, Nishioka M, Takahashi K, Akashige T, Nagata N. Hypoplastic left heart syndrome with right ventricle compression. Ann Thorac Surg. 2015;100:e15.17.CrossRef Fuchigami T, Nishioka M, Takahashi K, Akashige T, Nagata N. Hypoplastic left heart syndrome with right ventricle compression. Ann Thorac Surg. 2015;100:e15.17.CrossRef
2.
go back to reference Yeh T Jr, Connelly MS, Coles JG, Webb GD, McLaughlin PR, Freedom RM, et al. Atrioventricular discordance: results of repair in 127 patients. J Thorac Cardiovasc Surg. 1999;117:1190.1203. Yeh T Jr, Connelly MS, Coles JG, Webb GD, McLaughlin PR, Freedom RM, et al. Atrioventricular discordance: results of repair in 127 patients. J Thorac Cardiovasc Surg. 1999;117:1190.1203.
3.
go back to reference Sharma R, Marwah A, Shah S, Maheshwari S. Isolated atrioventricular discordance: surgical experience. Ann Thorac Surg. 2008;85:1403.1406.CrossRef Sharma R, Marwah A, Shah S, Maheshwari S. Isolated atrioventricular discordance: surgical experience. Ann Thorac Surg. 2008;85:1403.1406.CrossRef
4.
go back to reference Fujita T, Fukushima S, Fukushima N, Shiraishi I, Kobayashi J. Three-dimensional replica of corrected transposition of the great arteries for successful heart transplantation. J Artif Organs. 2017;20:289.291.CrossRefPubMed Fujita T, Fukushima S, Fukushima N, Shiraishi I, Kobayashi J. Three-dimensional replica of corrected transposition of the great arteries for successful heart transplantation. J Artif Organs. 2017;20:289.291.CrossRefPubMed
Metadata
Title
Anatomical correction of atrioventricular discordance using three-dimensional replica
Authors
Tai Fuchigami
Masahiko Nishioka
Toru Akashige
Mami Nakayashiro
Nobuhiro Nagata
Publication date
01-06-2019
Publisher
Springer Singapore
Published in
General Thoracic and Cardiovascular Surgery / Issue 6/2019
Print ISSN: 1863-6705
Electronic ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-018-0944-8

Other articles of this Issue 6/2019

General Thoracic and Cardiovascular Surgery 6/2019 Go to the issue