Abstract

Bioprosthesis are commonly used in the elderly population. Structural valve deterioration affects the long-term durability. We report an early deterioration of a Mitroflow valve caused by ring deformation and prosthetic leaflet rupture. The 69-years-old patient underwent successful redo surgery with excision of the bioprosthesis and placement of a mechanical valve.
Literature
1.
go back to reference Butany J, Feng T, Suri R, Law K. Mitroflow pericardial bioprosthesis: structured failure at 4.5 years. Cardiovasc Pathol 2012; 506–10. Butany J, Feng T, Suri R, Law K. Mitroflow pericardial bioprosthesis: structured failure at 4.5 years. Cardiovasc Pathol 2012; 506–10.
2.
go back to reference Agrifoglio M, Gennari M, Kassem S, Polvani G. Saphenous vein cannulation in re-redo cardiac surgery. J Card Surg 2012; 676–7. Agrifoglio M, Gennari M, Kassem S, Polvani G. Saphenous vein cannulation in re-redo cardiac surgery. J Card Surg 2012; 676–7.
3.
go back to reference Joshi V, Prosser K, Richens D. Early prosthetic valve degeneration with Mitroflow aortic valves: determination of incidence and risk factors. Interact Cardiovasc Thorac Surg 2014; 36–40. Joshi V, Prosser K, Richens D. Early prosthetic valve degeneration with Mitroflow aortic valves: determination of incidence and risk factors. Interact Cardiovasc Thorac Surg 2014; 36–40.
4.
go back to reference Martinez Cereijo JM, Alvarez JR, Quiroga JS, Martinez de Alegria A. Is distortion of the bioprosthesis ring a risk factor for early calcification?. J Cardiothorac Surg 2010; 77. Martinez Cereijo JM, Alvarez JR, Quiroga JS, Martinez de Alegria A. Is distortion of the bioprosthesis ring a risk factor for early calcification?. J Cardiothorac Surg 2010; 77.
5.
go back to reference Luk A, Cusimano RJ, Butany J. Pathologic evaluation of 28 mitroflow pericardial valves: a 12-year experience. Ann Thorac Surg 2015; 48–54. Luk A, Cusimano RJ, Butany J. Pathologic evaluation of 28 mitroflow pericardial valves: a 12-year experience. Ann Thorac Surg 2015; 48–54.
Metadata
Title
Undiagnosed mitroflow bioprosthesis deformation causing early structural valve deterioration
Authors
Marco Gennari
Gianluca Polvani
Mara Rubino
Francesco Arlati
Andrea Annoni
Marco Agrifoglio
Publication date
01-09-2018
Publisher
Springer Japan
Published in
General Thoracic and Cardiovascular Surgery / Issue 9/2018
Print ISSN: 1863-6705
Electronic ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-017-0868-8

Other articles of this Issue 9/2018

General Thoracic and Cardiovascular Surgery 9/2018 Go to the issue