Skip to main content
Top
Published in: Obesity Surgery 8/2015

01-08-2015 | Original Contributions

Using Ligasure™ or Harmonic Ace® in Laparoscopic Sleeve Gastrectomies? A Prospective Randomized Study

Authors: Dimitrios Tsamis, Maria Natoudi, Aggeliki Arapaki, Ioannis Flessas, Ioanna Papailiou, Konstantinos Bramis, Georgios Zografos, Emmanouil Leandros, Konstantinos Albanopoulos

Published in: Obesity Surgery | Issue 8/2015

Login to get access

Abstract

Background

Laparoscopic sleeve gastrectomy is one of the most recent advances of surgery for treating morbid obesity. Many laparoscopic devices have evolved to provide vascular control and tissue dissection.

Methods

This is a prospective randomized study comparing the intraoperative and postoperative complications and operative time of two groups of patients who underwent laparoscopic sleeve gastrectomy. In the first group after randomization, sleeve gastrectomy was performed using Ligasure™ and in the second group Harmonic Ace® was used.

Results

In total, 94 patients were enrolled in the study allocated in two groups. In group 1, 43 patients were operated using Ligasure™, and in group 2, 51 patients were operated using Harmonic Ace®. No significant differences were highlighted between these two groups with regards to operative time (45.0 ± 15.0 vs 40.0 ± 20.0 min, p = 0.199), intraoperative complications (32.6 vs 15.7 %, p = 0.054) and postoperative complications (4.7 vs 17.6 %, p = 0.051).

Conclusions

Both Ligasure™ and Harmonic Ace® provide surgeons ergonomy, and no significant differences were shown in operative time and complications. Safety and efficacy in such demanding operations is of critical importance. Choice between these two shears lies with surgeon’s preference.
Literature
2.
go back to reference Targarona EM, Balague C, Marin J, et al. Energy sources for laparoscopic colectomy: a prospective randomized comparison of conventional electrosurgery, bipolar computer-controlled electrosurgery and ultrasonic dissection. Operative outcome and costs analysis. Surg Innov. 2005;12(4):339–44.PubMedCrossRef Targarona EM, Balague C, Marin J, et al. Energy sources for laparoscopic colectomy: a prospective randomized comparison of conventional electrosurgery, bipolar computer-controlled electrosurgery and ultrasonic dissection. Operative outcome and costs analysis. Surg Innov. 2005;12(4):339–44.PubMedCrossRef
3.
go back to reference Lopez J, Vilallonga R, Targarona EM, et al. Can LigaSure™ be used to perform sleeve gastrectomy? - Tensile strength and histological changes. Minim Invasive Ther Allied Technol. 2013. Lopez J, Vilallonga R, Targarona EM, et al. Can LigaSure™ be used to perform sleeve gastrectomy? - Tensile strength and histological changes. Minim Invasive Ther Allied Technol. 2013.
4.
go back to reference Campagnacci R, de Sanctis A, Baldarelli M, et al. Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study. Surg Endosc. 2007;21(9):1526–31.PubMedCrossRef Campagnacci R, de Sanctis A, Baldarelli M, et al. Electrothermal bipolar vessel sealing device vs. ultrasonic coagulating shears in laparoscopic colectomies: a comparative study. Surg Endosc. 2007;21(9):1526–31.PubMedCrossRef
6.
go back to reference D'Hondt M, Vanneste S, Pottel H, et al. Laparoscopic sleeve gastrectomy as a single-stage procedure for the treatment of morbid obesity and the resulting quality of life, resolution of comorbidities, food tolerance, and 6-year weight loss. Surg Endosc. 2011;25(8):2498–504. doi:10.1007/s00464-011-1572-x.PubMedCrossRef D'Hondt M, Vanneste S, Pottel H, et al. Laparoscopic sleeve gastrectomy as a single-stage procedure for the treatment of morbid obesity and the resulting quality of life, resolution of comorbidities, food tolerance, and 6-year weight loss. Surg Endosc. 2011;25(8):2498–504. doi:10.​1007/​s00464-011-1572-x.PubMedCrossRef
7.
go back to reference Barrett WL, Garber SM. Surgical smoke: a review of the literature. Is this just a lot of hot air? Surg Endosc. 2003;17:979–87.PubMedCrossRef Barrett WL, Garber SM. Surgical smoke: a review of the literature. Is this just a lot of hot air? Surg Endosc. 2003;17:979–87.PubMedCrossRef
8.
go back to reference Harrell AG, Kercher KW, Heniford BT. Energy sources in laparoscopy. Semin Laparosc Surg. 2004;11:201–9.PubMed Harrell AG, Kercher KW, Heniford BT. Energy sources in laparoscopy. Semin Laparosc Surg. 2004;11:201–9.PubMed
11.
go back to reference Kwok SY, Chung CC, Tsui KK, et al. A double-blind, randomized trial comparing Ligasure and Harmonic Scalpel hemorrhoidectomy. Dis Colon Rectum. 2005;48(2):344–8.PubMedCrossRef Kwok SY, Chung CC, Tsui KK, et al. A double-blind, randomized trial comparing Ligasure and Harmonic Scalpel hemorrhoidectomy. Dis Colon Rectum. 2005;48(2):344–8.PubMedCrossRef
12.
go back to reference Miccoli P, Berti P, Dionigi GL, et al. Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg. 2006;132:1069–73.PubMedCrossRef Miccoli P, Berti P, Dionigi GL, et al. Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg. 2006;132:1069–73.PubMedCrossRef
13.
go back to reference Petrakis IE, Kogerakis NE, Lasithiotakis KG, et al. LigaSure versus clamp-and-tie thyroidectomy for benign nodular disease. Head Neck. 2004;26:903–9.PubMedCrossRef Petrakis IE, Kogerakis NE, Lasithiotakis KG, et al. LigaSure versus clamp-and-tie thyroidectomy for benign nodular disease. Head Neck. 2004;26:903–9.PubMedCrossRef
14.
go back to reference Harold KL, Pollinger H, Matthews BD, et al. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc. 2003;17:1128–230. Harold KL, Pollinger H, Matthews BD, et al. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc. 2003;17:1128–230.
15.
go back to reference Heniford BT, Matthews BD, Sting RF, et al. Initial results with an electrothermal bipolar vessel sealer. Surg Endosc. 2001;15:799–801.PubMedCrossRef Heniford BT, Matthews BD, Sting RF, et al. Initial results with an electrothermal bipolar vessel sealer. Surg Endosc. 2001;15:799–801.PubMedCrossRef
16.
go back to reference Takada M, Ichihara T, Kuroda Y. Comparative study of electrothermal bipolar vessel sealer and ultrasonic coagulating shears in laparoscopic colectomy. Surg Endosc. 2005;19:226–8.PubMedCrossRef Takada M, Ichihara T, Kuroda Y. Comparative study of electrothermal bipolar vessel sealer and ultrasonic coagulating shears in laparoscopic colectomy. Surg Endosc. 2005;19:226–8.PubMedCrossRef
Metadata
Title
Using Ligasure™ or Harmonic Ace® in Laparoscopic Sleeve Gastrectomies? A Prospective Randomized Study
Authors
Dimitrios Tsamis
Maria Natoudi
Aggeliki Arapaki
Ioannis Flessas
Ioanna Papailiou
Konstantinos Bramis
Georgios Zografos
Emmanouil Leandros
Konstantinos Albanopoulos
Publication date
01-08-2015
Publisher
Springer US
Published in
Obesity Surgery / Issue 8/2015
Print ISSN: 0960-8923
Electronic ISSN: 1708-0428
DOI
https://doi.org/10.1007/s11695-014-1551-0

Other articles of this Issue 8/2015

Obesity Surgery 8/2015 Go to the issue