Ethanol fixation method for heart and lung imaging in micro-CT

Authors: Matej Patzelt, Jana Mrzilkova, Jan Dudak, Frantisek Krejci, Jan Zemlicka, Jakub Karch, Vladimir Musil, Jozef Rosina, Viktor Sykora, Barbora Horehledova, Petr Zach

Published in: Japanese Journal of Radiology | Issue 6/2019

Login to get access

Abstract

Purpose

The soft tissue imaging in micro-CT remains challenging due to its low intrinsic contrast. The aim of this study was to create a simple staining method omitting the usage of contrast agents for ex vivo soft tissue imaging in micro-CT.

Materials and methods

Hearts and lungs from 30 mice were used. Twenty-seven organs were either fixed in 97% or 50% ethanol solution or in a series of ascending ethanol concentrations. Images were acquired after 72, 168 and 336 h on a custom-built micro-CT machine and compared to scans of three native samples.

Results

Ethanol provided contrast enhancement in all evaluated fixations. Fixation in 97% ethanol resulted in contrast enhancement after 72 h; however, it caused hardening of the samples. Fixation in 50% ethanol provided contrast enhancement after 336 h, with milder hardening, compared to the 97% ethanol fixation, but the visualization of details was worse. The fixation in a series of ascending ethanol concentrations provided the most satisfactory results; all organs were visualized in great detail without tissue damage.

Conclusions

Simple ethanol fixation improves the tissue contrast enhancement in micro-CT. The best results can be obtained with fixation of the soft tissue samples in a series of ascending ethanol concentrations.
Literature
6.
go back to reference Descamps E, Sochacka A, De Kegel B, Van Loo D, Van Hoorebeke L, Adriaens D. Soft tissue discrimination with contrast agents using micro-CT scanning. Belg J Zool. 2014;144(1):20–40. Descamps E, Sochacka A, De Kegel B, Van Loo D, Van Hoorebeke L, Adriaens D. Soft tissue discrimination with contrast agents using micro-CT scanning. Belg J Zool. 2014;144(1):20–40.
17.
25.
go back to reference Dudak J, Zemlicka J, Karch J, Patzelt M, Mrzilkova J, Zach P, et al. High-contrast X-ray micro-radiography and micro-CT of ex vivo soft tissue murine organs utilizing ethanol fixation and large area photon-counting detector. Sci Rep-UK. 2016;6:30385. https://doi.org/10.1038/Srep30385.CrossRef Dudak J, Zemlicka J, Karch J, Patzelt M, Mrzilkova J, Zach P, et al. High-contrast X-ray micro-radiography and micro-CT of ex vivo soft tissue murine organs utilizing ethanol fixation and large area photon-counting detector. Sci Rep-UK. 2016;6:30385. https://​doi.​org/​10.​1038/​Srep30385.CrossRef
Metadata
Title
Ethanol fixation method for heart and lung imaging in micro-CT
Authors
Matej Patzelt
Jana Mrzilkova
Jan Dudak
Frantisek Krejci
Jan Zemlicka
Jakub Karch
Vladimir Musil
Jozef Rosina
Viktor Sykora
Barbora Horehledova
Petr Zach
Publication date
01-06-2019
Publisher
Springer Japan
Published in
Japanese Journal of Radiology / Issue 6/2019
Print ISSN: 1867-1071
Electronic ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-019-00830-6

Other articles of this Issue 6/2019

Japanese Journal of Radiology 6/2019 Go to the issue