Skip to main content
Top
Published in: Japanese Journal of Radiology 4/2019

01-04-2019 | Original Article

Radiation dose reduction using two orthogonal topograms associated with automatic tube voltage selection for lung CT scanning as compared with a single anteroposterior topogram

Authors: Xiaofei Liu, Mingming Zhang, Liang Zhang, Yu Zhao, Wenge Sun

Published in: Japanese Journal of Radiology | Issue 4/2019

Login to get access

Abstract

Objective

To evaluate the effectiveness of two orthogonal topograms on radiation dose and image quality (IQ) associated with topogram-based automatic tube voltage selection (ATVS) for lung CT scanning.

Methods

Thirty-seven patients were enrolled in this study. At baseline, only an anteroposterior topogram was obtained and at follow-up, both anteroposterior and lateral topograms were performed. ATVS was turned on during all scans. Objective and subjective IQ evaluations were performed and compared; tube voltage and radiation dose of each scan were noted and analyzed.

Results

A significant difference was observed regarding the objective parameters between baseline and follow-up only in image noise and signal–noise ratio (SNR) in the upper one-third of the image (image noise: 7.49 ± 1.08 vs. 9.10 ± 1.13, p < 0.001; SNR: 4.08 ± 0.87 vs. 3.37 ± 0.63, p < 0.001). No differences were found between baseline and follow-up in the subjective assessment of IQ. The radiation dose was significantly lower at follow-up than that at baseline (2.73 ± 0.83 mSv vs. 3.55 ± 1.24 mSv, respectively; p < 0.001).

Conclusions

Using two orthogonal topograms associated with ATVS could significantly reduce the total radiation dose for lung CT scanning, while subjective IQ was maintained.
Literature
1.
go back to reference Kalra MK, Maher MM, Toth TL, Schmidt B, Westerman BL, Morgan HT, et al. Techniques and applications of automatic tube current modulation for CT. Radiology. 2004;233(3):649–57.CrossRefPubMed Kalra MK, Maher MM, Toth TL, Schmidt B, Westerman BL, Morgan HT, et al. Techniques and applications of automatic tube current modulation for CT. Radiology. 2004;233(3):649–57.CrossRefPubMed
2.
go back to reference McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: overview of available options. Radiographics. 2006;26(2):503–12.CrossRefPubMed McCollough CH, Bruesewitz MR, Kofler JM Jr. CT dose reduction and dose management tools: overview of available options. Radiographics. 2006;26(2):503–12.CrossRefPubMed
3.
go back to reference Raman SP, Johnson PT, Deshmukh S, Mahesh M, Grant KL, Fishman EK. CT dose reduction applications: available tools on the latest generation of CT scanners. J Am Coll Radiol. 2013;10(1):37–41.CrossRefPubMed Raman SP, Johnson PT, Deshmukh S, Mahesh M, Grant KL, Fishman EK. CT dose reduction applications: available tools on the latest generation of CT scanners. J Am Coll Radiol. 2013;10(1):37–41.CrossRefPubMed
4.
go back to reference Soderberg M, Gunnarsson M. The effect of different adaptation strengths on image quality and radiation dose using Siemens Care Dose 4D. Radiat Prot Dosimetry. 2010;139(1–3):173–9.CrossRefPubMed Soderberg M, Gunnarsson M. The effect of different adaptation strengths on image quality and radiation dose using Siemens Care Dose 4D. Radiat Prot Dosimetry. 2010;139(1–3):173–9.CrossRefPubMed
5.
go back to reference Frellesen C, Stock W, Kerl JM, Lehnert T, Wichmann JL, Nau C, et al. Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT—a comparison to fixed kV with mAs modulation alone. Eur Radiol. 2014;24(7):1725–34.CrossRefPubMed Frellesen C, Stock W, Kerl JM, Lehnert T, Wichmann JL, Nau C, et al. Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT—a comparison to fixed kV with mAs modulation alone. Eur Radiol. 2014;24(7):1725–34.CrossRefPubMed
6.
go back to reference Mangold S, Wichmann JL, Schoepf UJ, Poole ZB, Canstein C, Varga-Szemes A, et al. Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3(rd) generation dual-source CT. Eur Radiol. 2016;26(10):3608–16.CrossRefPubMed Mangold S, Wichmann JL, Schoepf UJ, Poole ZB, Canstein C, Varga-Szemes A, et al. Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3(rd) generation dual-source CT. Eur Radiol. 2016;26(10):3608–16.CrossRefPubMed
7.
go back to reference O’Daniel JC, Stevens DM, Cody DD. Reducing radiation exposure from survey CT scans. AJR Am J Roentgenol. 2005;185(2):509–15.CrossRefPubMed O’Daniel JC, Stevens DM, Cody DD. Reducing radiation exposure from survey CT scans. AJR Am J Roentgenol. 2005;185(2):509–15.CrossRefPubMed
8.
go back to reference Strauss KJ, Goske MJ, Kaste SC, Bulas D, Frush DP, Butler P, et al. Image gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients. AJR Am J Roentgenol. 2010;194(4):868–73.CrossRefPubMed Strauss KJ, Goske MJ, Kaste SC, Bulas D, Frush DP, Butler P, et al. Image gently: ten steps you can take to optimize image quality and lower CT dose for pediatric patients. AJR Am J Roentgenol. 2010;194(4):868–73.CrossRefPubMed
9.
go back to reference Singh S, Petrovic D, Jamnik E, Aran S, Pourjabbar S, Kave ML, et al. Effect of localizer radiograph on radiation dose associated with automatic exposure control: human cadaver and patient study. J Comput Assist Tomogr. 2014;38(2):293–8.CrossRefPubMed Singh S, Petrovic D, Jamnik E, Aran S, Pourjabbar S, Kave ML, et al. Effect of localizer radiograph on radiation dose associated with automatic exposure control: human cadaver and patient study. J Comput Assist Tomogr. 2014;38(2):293–8.CrossRefPubMed
10.
go back to reference Feng R, Tong J, Liu X, Zhao Y, Zhang L. High-pitch coronary CT angiography at 70 kVp adopting a protocol of low injection speed and low volume of contrast medium. Korean J Radiol. 2017;18(5):763–72.CrossRefPubMedPubMedCentral Feng R, Tong J, Liu X, Zhao Y, Zhang L. High-pitch coronary CT angiography at 70 kVp adopting a protocol of low injection speed and low volume of contrast medium. Korean J Radiol. 2017;18(5):763–72.CrossRefPubMedPubMedCentral
11.
go back to reference Zhang LJ, Qi L, Wang J, Tang CX, Zhou CS, Ji XM, et al. Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience. Eur Radiol. 2014;24:1537–46.CrossRefPubMed Zhang LJ, Qi L, Wang J, Tang CX, Zhou CS, Ji XM, et al. Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience. Eur Radiol. 2014;24:1537–46.CrossRefPubMed
14.
go back to reference Christner JA, Braun NN, Jacobsen MC, Carter RE, Kofler JM, McCollough CH. Size-specific dose estimates for adult patients at CT of the torso. Radiology. 2012;265:841–7.CrossRefPubMed Christner JA, Braun NN, Jacobsen MC, Carter RE, Kofler JM, McCollough CH. Size-specific dose estimates for adult patients at CT of the torso. Radiology. 2012;265:841–7.CrossRefPubMed
15.
go back to reference Mangold S, De Cecco CN, Schoepf UJ, Kuhlman TS, Varga-Szemes A, Caruso D, et al. CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: image quality and radiation exposure. Eur J Radiol. 2017;86:276–83.CrossRefPubMed Mangold S, De Cecco CN, Schoepf UJ, Kuhlman TS, Varga-Szemes A, Caruso D, et al. CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: image quality and radiation exposure. Eur J Radiol. 2017;86:276–83.CrossRefPubMed
16.
go back to reference Mangold S, De Cecco CN, Wichmann JL, Canstein C, Varga-Szemes A, Caruso D, et al. Effect of automated tube voltage selection, integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of 3rd generation dual-source aortic CT angiography: an intra-individual comparison. Eur J Radiol. 2016;85(5):972–8.CrossRefPubMed Mangold S, De Cecco CN, Wichmann JL, Canstein C, Varga-Szemes A, Caruso D, et al. Effect of automated tube voltage selection, integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of 3rd generation dual-source aortic CT angiography: an intra-individual comparison. Eur J Radiol. 2016;85(5):972–8.CrossRefPubMed
17.
go back to reference Park C, Gruber-Rouh T, Leithner D, Zierden A, Albrecht MH, Wichmann JL, et al. Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT. Cancer Imaging. 2016;16(1):33.CrossRefPubMedPubMedCentral Park C, Gruber-Rouh T, Leithner D, Zierden A, Albrecht MH, Wichmann JL, et al. Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT. Cancer Imaging. 2016;16(1):33.CrossRefPubMedPubMedCentral
18.
go back to reference Zhang LJ, Qi L, Wang J, Tang CX, Zhou CS, Ji XM, et al. Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience. Eur Radiol. 2014;24(7):1537–46.CrossRefPubMed Zhang LJ, Qi L, Wang J, Tang CX, Zhou CS, Ji XM, et al. Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience. Eur Radiol. 2014;24(7):1537–46.CrossRefPubMed
19.
go back to reference Achenbach S, Marwan M, Ropers D, Schepis T, Pflederer T, Anders K, et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J. 2010;31(3):340–6.CrossRefPubMed Achenbach S, Marwan M, Ropers D, Schepis T, Pflederer T, Anders K, et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J. 2010;31(3):340–6.CrossRefPubMed
20.
go back to reference Ghoshhajra BB, Engel LC, Major GP, Verdini D, Sidhu M, Karolyi M, et al. Direct chest area measurement: a potential anthropometric replacement for BMI to inform cardiac CT dose parameters? J Cardiovasc Comput Tomogr. 2011;5(4):240–6.CrossRefPubMed Ghoshhajra BB, Engel LC, Major GP, Verdini D, Sidhu M, Karolyi M, et al. Direct chest area measurement: a potential anthropometric replacement for BMI to inform cardiac CT dose parameters? J Cardiovasc Comput Tomogr. 2011;5(4):240–6.CrossRefPubMed
21.
go back to reference Li JL, Huang MP, Liang CH, Zhao ZJ, Liu H, Cui YH, et al. Individualized radiation dose control in 256-slice CT coronary angiography (CTCA) in retrospective ECG-triggered helical scans: using a measure of body size to adjust tube current selection. Eur J Radiol. 2012;81(11):3146–53.CrossRefPubMed Li JL, Huang MP, Liang CH, Zhao ZJ, Liu H, Cui YH, et al. Individualized radiation dose control in 256-slice CT coronary angiography (CTCA) in retrospective ECG-triggered helical scans: using a measure of body size to adjust tube current selection. Eur J Radiol. 2012;81(11):3146–53.CrossRefPubMed
Metadata
Title
Radiation dose reduction using two orthogonal topograms associated with automatic tube voltage selection for lung CT scanning as compared with a single anteroposterior topogram
Authors
Xiaofei Liu
Mingming Zhang
Liang Zhang
Yu Zhao
Wenge Sun
Publication date
01-04-2019
Publisher
Springer Japan
Published in
Japanese Journal of Radiology / Issue 4/2019
Print ISSN: 1867-1071
Electronic ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-018-00809-9

Other articles of this Issue 4/2019

Japanese Journal of Radiology 4/2019 Go to the issue