Skip to main content
Top
Published in: HAND 2/2008

01-06-2008 | Original Article

Computed Tomography for Triage of Suspected Scaphoid Fractures

Authors: Jennifer M. Ty, Santiago Lozano-Calderon, David Ring

Published in: HAND | Issue 2/2008

Login to get access

Abstract

The use of computed tomography (CT) to triage suspected scaphoid fractures is appealing because it is more readily available and less expensive than magnetic resonance imaging (MRI). Twenty-eight patients with suspected scaphoid fractures (defined as tenderness in the area of the scaphoid and initial scaphoid-specific radiographs interpreted as normal) were enrolled in a prospective protocol evaluating triage with CT. Twenty patients reached an endpoint consisting of either (1) identification of a fracture accounting for the patient’s symptoms on CT or (2) normal radiographs 6 weeks or more from the time of injury. Only 2 of 28 patients (7%) were diagnosed with a nondisplaced fracture of the scaphoid waist. CT revealed an avulsion fracture of the distal pole of the scaphoid in two patients, nondisplaced fractures of the distal radius in six patients, and nondisplaced fractures of other carpal bones in four patients. Radiographs of the scaphoid taken 6 weeks or greater from the time of injury were interpreted as normal in the six patients with normal CT scans that completed the study. True scaphoid waist fractures are uncommon among patients with suspected scaphoid fractures. CT scans are useful for triage of suspected scaphoid waist fractures because alternative, less-troublesome fractures were identified in 43% of patients and no fractures were missed or undertreated. Immediate triage of suspected scaphoid fractures using CT in the emergency room has the potential to reduce unnecessary immobilization and diminish overall costs associated with treatment.
Literature
1.
go back to reference Adey L, Souer JS, Lozano-Calderon S, Palmer W, Lee SG, Ring D. Computed tomography of suspected scaphoid fractures. J Hand Surg [Am] 2007;32(1):61–6.CrossRef Adey L, Souer JS, Lozano-Calderon S, Palmer W, Lee SG, Ring D. Computed tomography of suspected scaphoid fractures. J Hand Surg [Am] 2007;32(1):61–6.CrossRef
2.
go back to reference Amadio PC. Scaphoid fractures. Orthop Clin North Am 1992;23(1):7–17.PubMed Amadio PC. Scaphoid fractures. Orthop Clin North Am 1992;23(1):7–17.PubMed
3.
go back to reference Beeres FJ, Hogervorst M, Hollander P, Rhemrev S. Outcome of routine bone scintigraphy in suspected scaphoid fractures. Injury 2005;36(10):1233–6.PubMedCrossRef Beeres FJ, Hogervorst M, Hollander P, Rhemrev S. Outcome of routine bone scintigraphy in suspected scaphoid fractures. Injury 2005;36(10):1233–6.PubMedCrossRef
4.
go back to reference Bhat M, McCarthy M, Davis TR, Oni JA, Dawson S. MRI and plain radiography in the assessment of displaced fractures of the waist of the carpal scaphoid. J Bone Jt Surg Br 2004;86(5):705–13.CrossRef Bhat M, McCarthy M, Davis TR, Oni JA, Dawson S. MRI and plain radiography in the assessment of displaced fractures of the waist of the carpal scaphoid. J Bone Jt Surg Br 2004;86(5):705–13.CrossRef
5.
go back to reference Brydie A, Raby N. Early MRI in the management of clinical scaphoid fracture. Br J Radiol 2003;76(905):296–300.PubMedCrossRef Brydie A, Raby N. Early MRI in the management of clinical scaphoid fracture. Br J Radiol 2003;76(905):296–300.PubMedCrossRef
6.
go back to reference Chen S. The scaphoid compression test. J Hand Surg [Br] 1989;14(3):323–5. Chen S. The scaphoid compression test. J Hand Surg [Br] 1989;14(3):323–5.
7.
go back to reference Clay NR, Dias JJ, Costigan PS, Gregg PJ, Barton NJ. Need the thumb be immobilised in scaphoid fractures? A randomised prospective trial. J Bone Jt Surg Br 1991;73(5):828–32. Clay NR, Dias JJ, Costigan PS, Gregg PJ, Barton NJ. Need the thumb be immobilised in scaphoid fractures? A randomised prospective trial. J Bone Jt Surg Br 1991;73(5):828–32.
8.
go back to reference Dias JJ, Brenkel IJ, Finlay DB. Patterns of union in fractures of the waist of the scaphoid. J Bone Jt Surg Br 1989;71(2):307–10. Dias JJ, Brenkel IJ, Finlay DB. Patterns of union in fractures of the waist of the scaphoid. J Bone Jt Surg Br 1989;71(2):307–10.
9.
go back to reference Dias JJ, Thompson J, Barton NJ, Gregg PJ. Suspected scaphoid fractures. The value of radiographs. J Bone Jt Surg Br 1990;72(1):98–101. Dias JJ, Thompson J, Barton NJ, Gregg PJ. Suspected scaphoid fractures. The value of radiographs. J Bone Jt Surg Br 1990;72(1):98–101.
10.
go back to reference Dorsay TA, Major NM, Helms CA. Cost-effectiveness of immediate MR imaging versus traditional follow-up for revealing radiographically occult scaphoid fractures. AJR Am J Roentgenol 2001;177(6):1257–63.PubMed Dorsay TA, Major NM, Helms CA. Cost-effectiveness of immediate MR imaging versus traditional follow-up for revealing radiographically occult scaphoid fractures. AJR Am J Roentgenol 2001;177(6):1257–63.PubMed
11.
go back to reference Duppe H, Johnell O, Lundborg G, Karlsson M, Redlund-Johnell I. Long-term results of fracture of the scaphoid. A follow-up study of more than thirty years. J Bone Jt Surg Am 1994;76(2):249–52. Duppe H, Johnell O, Lundborg G, Karlsson M, Redlund-Johnell I. Long-term results of fracture of the scaphoid. A follow-up study of more than thirty years. J Bone Jt Surg Am 1994;76(2):249–52.
12.
go back to reference Foex B, Speake P, Body R. Best evidence topic report. Magnetic resonance imaging or bone scintigraphy in the diagnosis of plain x ray occult scaphoid fractures. Emerg Med J 2005;22(6):434–5.PubMedCrossRef Foex B, Speake P, Body R. Best evidence topic report. Magnetic resonance imaging or bone scintigraphy in the diagnosis of plain x ray occult scaphoid fractures. Emerg Med J 2005;22(6):434–5.PubMedCrossRef
13.
go back to reference Gaebler C, Kukla C, Breitenseher M, Trattnig S, Mittlboeck M, Vecsei V. Magnetic resonance imaging of occult scaphoid fractures. J Trauma 1996;41(1):73–6.PubMedCrossRef Gaebler C, Kukla C, Breitenseher M, Trattnig S, Mittlboeck M, Vecsei V. Magnetic resonance imaging of occult scaphoid fractures. J Trauma 1996;41(1):73–6.PubMedCrossRef
14.
go back to reference Gooding A, Coates M, Rothwell A. Cost analysis of traditional follow-up protocol versus MRI for radiographically occult scaphoid fractures: a pilot study for the Accident Compensation Corporation. N Z Med J 2004;117(1201):U1049.PubMed Gooding A, Coates M, Rothwell A. Cost analysis of traditional follow-up protocol versus MRI for radiographically occult scaphoid fractures: a pilot study for the Accident Compensation Corporation. N Z Med J 2004;117(1201):U1049.PubMed
15.
go back to reference Hambidge JE, Desai VV, Schranz PJ, Compson JP, Davis TR, Barton NJ. Acute fractures of the scaphoid. Treatment by cast immobilisation with the wrist in flexion or extension? J Bone Jt Surg Br 1999;81(1):91–2.CrossRef Hambidge JE, Desai VV, Schranz PJ, Compson JP, Davis TR, Barton NJ. Acute fractures of the scaphoid. Treatment by cast immobilisation with the wrist in flexion or extension? J Bone Jt Surg Br 1999;81(1):91–2.CrossRef
16.
go back to reference Hauger O, Bonnefoy O, Moinard M, Bersani D, Diard F. Occult fractures of the waist of the scaphoid: early diagnosis by high-spatial-resolution sonography. AJR Am J Roentgenol 2002;178(5):1239–45.PubMed Hauger O, Bonnefoy O, Moinard M, Bersani D, Diard F. Occult fractures of the waist of the scaphoid: early diagnosis by high-spatial-resolution sonography. AJR Am J Roentgenol 2002;178(5):1239–45.PubMed
17.
go back to reference Hove LM. Epidemiology of scaphoid fractures in Bergen, Norway. Scand J Plast Reconstr Surg Hand Surg 1999;33(4):423–6.PubMedCrossRef Hove LM. Epidemiology of scaphoid fractures in Bergen, Norway. Scand J Plast Reconstr Surg Hand Surg 1999;33(4):423–6.PubMedCrossRef
18.
go back to reference Kumar S, O’Connor A, Despois M, Galloway H. Use of early magnetic resonance imaging in the diagnosis of occult scaphoid fractures: the CAST study (Canberra Area Scaphoid Trial). N Z Med J 2005;118(1209):U1296.PubMed Kumar S, O’Connor A, Despois M, Galloway H. Use of early magnetic resonance imaging in the diagnosis of occult scaphoid fractures: the CAST study (Canberra Area Scaphoid Trial). N Z Med J 2005;118(1209):U1296.PubMed
19.
go back to reference Larsen CF, Brondum V, Skov O. Epidemiology of scaphoid fractures in Odense, Denmark. Acta Orthop Scand 1992;63(2):216–8.PubMed Larsen CF, Brondum V, Skov O. Epidemiology of scaphoid fractures in Odense, Denmark. Acta Orthop Scand 1992;63(2):216–8.PubMed
20.
go back to reference Memarsadeghi M, Breitenseher MJ, Schaefer-Prokop C, Weber M, Aldrian S, Gabler C, et al. Occult scaphoid fractures: comparison of multidetector CT and MR imaging—initial experience. Radiology. 2006;240(1):169–76.PubMedCrossRef Memarsadeghi M, Breitenseher MJ, Schaefer-Prokop C, Weber M, Aldrian S, Gabler C, et al. Occult scaphoid fractures: comparison of multidetector CT and MR imaging—initial experience. Radiology. 2006;240(1):169–76.PubMedCrossRef
21.
go back to reference Munk B, Frokjaer J, Larsen CF, Johannsen HG, Rasmussen LL, Edal A, et al. Diagnosis of scaphoid fractures. A prospective multicenter study of 1,052 patients with 160 fractures. Acta Orthop Scand 1995;66(4):359–60.PubMed Munk B, Frokjaer J, Larsen CF, Johannsen HG, Rasmussen LL, Edal A, et al. Diagnosis of scaphoid fractures. A prospective multicenter study of 1,052 patients with 160 fractures. Acta Orthop Scand 1995;66(4):359–60.PubMed
22.
go back to reference Phillips TG, Reibach AM, Slomiany WP. Diagnosis and management of scaphoid fractures. Am Fam Phys 2004;70(5):879–84. Phillips TG, Reibach AM, Slomiany WP. Diagnosis and management of scaphoid fractures. Am Fam Phys 2004;70(5):879–84.
23.
go back to reference Ring D, Jupiter JB, Herndon JH. Acute fractures of the scaphoid. J Am Acad Orthop Surg 2000;8(4):225–31.PubMed Ring D, Jupiter JB, Herndon JH. Acute fractures of the scaphoid. J Am Acad Orthop Surg 2000;8(4):225–31.PubMed
24.
go back to reference Sanders WE. Evaluation of the humpback scaphoid by computed tomography in the longitudinal axial plane of the scaphoid. J Hand Surg [Am] 1988;13(2):182–7. Sanders WE. Evaluation of the humpback scaphoid by computed tomography in the longitudinal axial plane of the scaphoid. J Hand Surg [Am] 1988;13(2):182–7.
25.
go back to reference Sanders WE. Evaluation of the humpback scaphoid by computed tomography in the longitudinal axial plane of the scaphoid. J Hand Surg 1988;13:182–7.CrossRef Sanders WE. Evaluation of the humpback scaphoid by computed tomography in the longitudinal axial plane of the scaphoid. J Hand Surg 1988;13:182–7.CrossRef
26.
go back to reference Saxena P, McDonald R, Gull S, Hyder N. Diagnostic scanning for suspected scaphoid fractures: an economic evaluation based on cost-minimisation models. Injury 2003;34(7):503–11.PubMedCrossRef Saxena P, McDonald R, Gull S, Hyder N. Diagnostic scanning for suspected scaphoid fractures: an economic evaluation based on cost-minimisation models. Injury 2003;34(7):503–11.PubMedCrossRef
27.
go back to reference Senall JA, Failla JM, Bouffard JA, van Holsbeeck M. Ultrasound for the early diagnosis of clinically suspected scaphoid fracture. J Hand Surg [Am] 2004;29(3):400–5.CrossRef Senall JA, Failla JM, Bouffard JA, van Holsbeeck M. Ultrasound for the early diagnosis of clinically suspected scaphoid fracture. J Hand Surg [Am] 2004;29(3):400–5.CrossRef
28.
go back to reference Staniforth P. Scaphoid fractures and wrist pain—time for new thinking. Injury 1991;22(6):435–6.PubMedCrossRef Staniforth P. Scaphoid fractures and wrist pain—time for new thinking. Injury 1991;22(6):435–6.PubMedCrossRef
29.
go back to reference Tiel-van Buul MM, van Beek EJ, Borm JJ, Gubler FM, Broekhuizen AH, van Royen EA. The value of radiographs and bone scintigraphy in suspected scaphoid fracture. A statistical analysis. J Hand Surg [Br] 1993;18(3):403–6. Tiel-van Buul MM, van Beek EJ, Borm JJ, Gubler FM, Broekhuizen AH, van Royen EA. The value of radiographs and bone scintigraphy in suspected scaphoid fracture. A statistical analysis. J Hand Surg [Br] 1993;18(3):403–6.
Metadata
Title
Computed Tomography for Triage of Suspected Scaphoid Fractures
Authors
Jennifer M. Ty
Santiago Lozano-Calderon
David Ring
Publication date
01-06-2008
Publisher
Springer-Verlag
Published in
HAND / Issue 2/2008
Print ISSN: 1558-9447
Electronic ISSN: 1558-9455
DOI
https://doi.org/10.1007/s11552-007-9077-8

Other articles of this Issue 2/2008

HAND 2/2008 Go to the issue