Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 6/2019

01-06-2019 | Original Article

Interactive Flying Frustums (IFFs): spatially aware surgical data visualization

Authors: Javad Fotouhi, Mathias Unberath, Tianyu Song, Wenhao Gu, Alex Johnson, Greg Osgood, Mehran Armand, Nassir Navab

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 6/2019

Login to get access

Abstract

Purpose:

As the trend toward minimally invasive and percutaneous interventions continues, the importance of appropriate surgical data visualization becomes more evident. Ineffective interventional data display techniques that yield poor ergonomics that hinder hand–eye coordination, and therefore promote frustration which can compromise on-task performance up to adverse outcome. A very common example of ineffective visualization is monitors attached to the base of mobile C-arm X-ray systems.

Methods:

We present a spatially and imaging geometry-aware paradigm for visualization of fluoroscopic images using Interactive Flying Frustums (IFFs) in a mixed reality environment. We exploit the fact that the C-arm imaging geometry can be modeled as a pinhole camera giving rise to an 11-degree-of-freedom view frustum on which the X-ray image can be translated while remaining valid. Visualizing IFFs to the surgeon in an augmented reality environment intuitively unites the virtual 2D X-ray image plane and the real 3D patient anatomy. To achieve this visualization, the surgeon and C-arm are tracked relative to the same coordinate frame using image-based localization and mapping, with the augmented reality environment being delivered to the surgeon via a state-of-the-art optical see-through head-mounted display.

Results:

The root-mean-squared error of C-arm source tracking after hand–eye calibration was determined as \(0.43^{\circ }\pm 0.34^{\circ }\) and \(4.6\pm 2.7\,\hbox {mm}\) in rotation and translation, respectively. Finally, we demonstrated the application of spatially aware data visualization for internal fixation of pelvic fractures and percutaneous vertebroplasty.

Conclusion:

Our spatially aware approach to transmission image visualization effectively unites patient anatomy with X-ray images by enabling spatial image manipulation that abides image formation. Our proof-of-principle findings indicate potential applications for surgical tasks that mostly rely on orientational information such as placing the acetabular component in total hip arthroplasty, making us confident that the proposed augmented reality concept can pave the way for improving surgical performance and visuo-motor coordination in fluoroscopy-guided surgery.
Literature
1.
go back to reference Alambeigi F, Wang Y, Sefati S, Gao C, Murphy RJ, Iordachita I, Taylor RH, Khanuja H, Armand M (2017) A curved-drilling approach in core decompression of the femoral head osteonecrosis using a continuum manipulator. IEEE Robot Autom Lett 2(3):1480–1487CrossRef Alambeigi F, Wang Y, Sefati S, Gao C, Murphy RJ, Iordachita I, Taylor RH, Khanuja H, Armand M (2017) A curved-drilling approach in core decompression of the femoral head osteonecrosis using a continuum manipulator. IEEE Robot Autom Lett 2(3):1480–1487CrossRef
2.
go back to reference Andress S, Johnson A, Unberath M, Winkler AF, Yu K, Fotouhi J, Weidert S, Osgood G, Navab N (2018) On-the-fly augmented reality for orthopedic surgery using a multimodal fiducial. J Med Imaging 5(2):021209CrossRef Andress S, Johnson A, Unberath M, Winkler AF, Yu K, Fotouhi J, Weidert S, Osgood G, Navab N (2018) On-the-fly augmented reality for orthopedic surgery using a multimodal fiducial. J Med Imaging 5(2):021209CrossRef
3.
go back to reference Assarsson U, Moller T (2000) Optimized view frustum culling algorithms for bounding boxes. J Graph Tools 5(1):9–22CrossRef Assarsson U, Moller T (2000) Optimized view frustum culling algorithms for bounding boxes. J Graph Tools 5(1):9–22CrossRef
4.
go back to reference Atria C, Last L, Packard N, Noo F (2018) Cone beam tomosynthesis fluoroscopy: a new approach to 3d image guidance. In: Medical imaging 2018: image-guided procedures, robotic interventions, and modeling, vol 10576. International Society for Optics and Photonics, p 105762V Atria C, Last L, Packard N, Noo F (2018) Cone beam tomosynthesis fluoroscopy: a new approach to 3d image guidance. In: Medical imaging 2018: image-guided procedures, robotic interventions, and modeling, vol 10576. International Society for Optics and Photonics, p 105762V
6.
go back to reference Barr JD, Barr MS, Lemley TJ, McCann RM (2000) Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine 25(8):923–928CrossRefPubMed Barr JD, Barr MS, Lemley TJ, McCann RM (2000) Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine 25(8):923–928CrossRefPubMed
7.
go back to reference Boszczyk BM, Bierschneider M, Panzer S, Panzer W, Harstall R, Schmid K, Jaksche H (2006) Fluoroscopic radiation exposure of the kyphoplasty patient. Eur Spine J 15(3):347–355CrossRefPubMed Boszczyk BM, Bierschneider M, Panzer S, Panzer W, Harstall R, Schmid K, Jaksche H (2006) Fluoroscopic radiation exposure of the kyphoplasty patient. Eur Spine J 15(3):347–355CrossRefPubMed
8.
go back to reference Cardin MA, Wang JX, Plewes DB (2005) A method to evaluate human spatial coordination interfaces for computer-assisted surgery. Med Image Comput Comput Assist Interv MICCAI 2005:9–16 Cardin MA, Wang JX, Plewes DB (2005) A method to evaluate human spatial coordination interfaces for computer-assisted surgery. Med Image Comput Comput Assist Interv MICCAI 2005:9–16
9.
go back to reference Chen X, Xu L, Wang Y, Wang H, Wang F, Zeng X, Wang Q, Egger J (2015) Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display. J Biomed Inform 55:124–131CrossRefPubMed Chen X, Xu L, Wang Y, Wang H, Wang F, Zeng X, Wang Q, Egger J (2015) Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display. J Biomed Inform 55:124–131CrossRefPubMed
10.
go back to reference Chimenti PC, Mitten DJ (2015) Google glass as an alternative to standard fluoroscopic visualization for percutaneous fixation of hand fractures: a pilot study. Plast Reconstr Surg 136(2):328–330CrossRefPubMed Chimenti PC, Mitten DJ (2015) Google glass as an alternative to standard fluoroscopic visualization for percutaneous fixation of hand fractures: a pilot study. Plast Reconstr Surg 136(2):328–330CrossRefPubMed
11.
go back to reference Deib G, Johnson A, Unberath M, Yu K, Andress S, Qian L, Osgood G, Navab N, Hui F, Gailloud P (2018) Image guided percutaneous spine procedures using an optical see-through head mounted display: proof of concept and rationale. J Neurointerv Surg 10:1187–1191CrossRefPubMed Deib G, Johnson A, Unberath M, Yu K, Andress S, Qian L, Osgood G, Navab N, Hui F, Gailloud P (2018) Image guided percutaneous spine procedures using an optical see-through head mounted display: proof of concept and rationale. J Neurointerv Surg 10:1187–1191CrossRefPubMed
12.
go back to reference Endres F, Hess J, Engelhard N, Sturm J, Cremers D, Burgard W (2012) An evaluation of the RGB-D SLAM system. In: 2012 IEEE international conference on robotics and automation (ICRA). IEEE, pp 1691–1696 Endres F, Hess J, Engelhard N, Sturm J, Cremers D, Burgard W (2012) An evaluation of the RGB-D SLAM system. In: 2012 IEEE international conference on robotics and automation (ICRA). IEEE, pp 1691–1696
13.
go back to reference Fischer M, Fuerst B, Lee SC, Fotouhi J, Habert S, Weidert S, Euler E, Osgood G, Navab N (2016) Preclinical usability study of multiple augmented reality concepts for K-wire placement. Int J Comput Assist Radiol Surg 11(6):1007–1014CrossRefPubMed Fischer M, Fuerst B, Lee SC, Fotouhi J, Habert S, Weidert S, Euler E, Osgood G, Navab N (2016) Preclinical usability study of multiple augmented reality concepts for K-wire placement. Int J Comput Assist Radiol Surg 11(6):1007–1014CrossRefPubMed
14.
go back to reference Fotouhi J, Alexander CP, Unberath M, Taylor G, Lee SC, Fuerst B, Johnson A, Osgood GM, Taylor RH, Khanuja H, Armand M, Navab N (2018) Plan in 2-d, execute in 3-d: an augmented reality solution for cup placement in total hip arthroplasty. J Med Imaging 5(2):021205CrossRef Fotouhi J, Alexander CP, Unberath M, Taylor G, Lee SC, Fuerst B, Johnson A, Osgood GM, Taylor RH, Khanuja H, Armand M, Navab N (2018) Plan in 2-d, execute in 3-d: an augmented reality solution for cup placement in total hip arthroplasty. J Med Imaging 5(2):021205CrossRef
15.
go back to reference Fotouhi J, Fuerst B, Johnson A, Lee SC, Taylor R, Osgood G, Navab N, Armand M (2017) Pose-aware C-arm for automatic re-initialization of interventional 2d/3d image registration. Int J Comput Assist Radiol Surg 12(7):1221–1230CrossRefPubMedPubMedCentral Fotouhi J, Fuerst B, Johnson A, Lee SC, Taylor R, Osgood G, Navab N, Armand M (2017) Pose-aware C-arm for automatic re-initialization of interventional 2d/3d image registration. Int J Comput Assist Radiol Surg 12(7):1221–1230CrossRefPubMedPubMedCentral
16.
go back to reference Gafoor S, Schulz P, Heuer L, Matic P, Franke J, Bertog S, Reinartz M, Vaskelyte L, Hofmann I, Sievert H (2015) Use of echonavigator, a novel echocardiography–fluoroscopy overlay system, for transseptal puncture and left atrial appendage occlusion. J Interv Cardiol 28(2):215–217CrossRefPubMed Gafoor S, Schulz P, Heuer L, Matic P, Franke J, Bertog S, Reinartz M, Vaskelyte L, Hofmann I, Sievert H (2015) Use of echonavigator, a novel echocardiography–fluoroscopy overlay system, for transseptal puncture and left atrial appendage occlusion. J Interv Cardiol 28(2):215–217CrossRefPubMed
17.
go back to reference Georgel PF, Schroeder P, Navab N (2009) Navigation tools for viewing augmented cad models. IEEE Comput Graph Appl 29(6):65–73CrossRefPubMed Georgel PF, Schroeder P, Navab N (2009) Navigation tools for viewing augmented cad models. IEEE Comput Graph Appl 29(6):65–73CrossRefPubMed
18.
go back to reference Hajek J, Unberath M, Fotouhi J, Bier B, Lee SC, Osgood G, Maier A, Armand M, Navab N (2018) Closing the calibration loop: an inside-out-tracking paradigm for augmented reality in orthopedic surgery. arXiv preprint arXiv:1803.08610 Hajek J, Unberath M, Fotouhi J, Bier B, Lee SC, Osgood G, Maier A, Armand M, Navab N (2018) Closing the calibration loop: an inside-out-tracking paradigm for augmented reality in orthopedic surgery. arXiv preprint arXiv:​1803.​08610
19.
20.
go back to reference Hartley R, Zisserman A (2003) Multiple view geometry in computer vision. Cambridge University Press, Cambridge Hartley R, Zisserman A (2003) Multiple view geometry in computer vision. Cambridge University Press, Cambridge
21.
go back to reference Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VK, Dickman CA, Spetzler RF, Papadopoulos SM (2004) Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery 54(5):1131–1137CrossRefPubMed Hott JS, Deshmukh VR, Klopfenstein JD, Sonntag VK, Dickman CA, Spetzler RF, Papadopoulos SM (2004) Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases. Neurosurgery 54(5):1131–1137CrossRefPubMed
22.
go back to reference Joskowicz L, Hazan EJ (2016) Computer aided orthopaedic surgery: incremental shift or paradigm change? Med Image Anal 33:84–90CrossRefPubMed Joskowicz L, Hazan EJ (2016) Computer aided orthopaedic surgery: incremental shift or paradigm change? Med Image Anal 33:84–90CrossRefPubMed
23.
go back to reference Liebergall M, Mosheiff R, Joskowicz L (2006) Computer-aided orthopaedic surgery in skeletal trauma. In: Bucholz RW, Heckman JD, Court-Brown CM (eds) Rockwood and greens fractures in adults, 6th edn. Lippincott, Philadelphia, pp 739–767 Liebergall M, Mosheiff R, Joskowicz L (2006) Computer-aided orthopaedic surgery in skeletal trauma. In: Bucholz RW, Heckman JD, Court-Brown CM (eds) Rockwood and greens fractures in adults, 6th edn. Lippincott, Philadelphia, pp 739–767
24.
go back to reference Mason A, Paulsen R, Babuska JM, Rajpal S, Burneikiene S, Nelson EL, Villavicencio AT (2014) The accuracy of pedicle screw placement using intraoperative image guidance systems: a systematic review. J Neurosurg Spine 20(2):196–203CrossRefPubMed Mason A, Paulsen R, Babuska JM, Rajpal S, Burneikiene S, Nelson EL, Villavicencio AT (2014) The accuracy of pedicle screw placement using intraoperative image guidance systems: a systematic review. J Neurosurg Spine 20(2):196–203CrossRefPubMed
25.
go back to reference Miller DL, Vañó E, Bartal G, Balter S, Dixon R, Padovani R, Schueler B, Cardella JF, De Baère T (2010) Occupational radiation protection in interventional radiology: a joint guideline of the cardiovascular and interventional radiology society of Europe and the society of interventional radiology. Cardiovasc Intervent Radiol 33(2):230–239CrossRefPubMed Miller DL, Vañó E, Bartal G, Balter S, Dixon R, Padovani R, Schueler B, Cardella JF, De Baère T (2010) Occupational radiation protection in interventional radiology: a joint guideline of the cardiovascular and interventional radiology society of Europe and the society of interventional radiology. Cardiovasc Intervent Radiol 33(2):230–239CrossRefPubMed
26.
go back to reference Navab N, Mitschke M (2001) Method and apparatus using a virtual detector for three-dimensional reconstruction from x-ray images. US Patent 6,236,704 Navab N, Mitschke M (2001) Method and apparatus using a virtual detector for three-dimensional reconstruction from x-ray images. US Patent 6,236,704
27.
go back to reference Qian L, Deguet A, Kazanzides P (2018) Arssist: augmented reality on a head-mounted display for the first assistant in robotic surgery. Healthc Technol Lett 5:194–200CrossRefPubMedPubMedCentral Qian L, Deguet A, Kazanzides P (2018) Arssist: augmented reality on a head-mounted display for the first assistant in robotic surgery. Healthc Technol Lett 5:194–200CrossRefPubMedPubMedCentral
28.
go back to reference Qian L, Unberath M, Yu K, Fuerst B, Johnson A, Navab N, Osgood G (2017) Towards virtual monitors for image guided interventions-real-time streaming to optical see-through head-mounted displays. arXiv preprint arXiv:1710.00808 Qian L, Unberath M, Yu K, Fuerst B, Johnson A, Navab N, Osgood G (2017) Towards virtual monitors for image guided interventions-real-time streaming to optical see-through head-mounted displays. arXiv preprint arXiv:​1710.​00808
29.
go back to reference Routt MC Jr, Nork SE, Mills WJ (2000) Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res (1976–2007) 375:15–29CrossRef Routt MC Jr, Nork SE, Mills WJ (2000) Percutaneous fixation of pelvic ring disruptions. Clin Orthop Relat Res (1976–2007) 375:15–29CrossRef
30.
go back to reference Sefati S, Alambeigi F, Iordachita I, Armand M, Murphy RJ (2016) FBG-based large deflection shape sensing of a continuum manipulator: manufacturing optimization. In: 2016 IEEE SENSORS. IEEE, pp 1–3 Sefati S, Alambeigi F, Iordachita I, Armand M, Murphy RJ (2016) FBG-based large deflection shape sensing of a continuum manipulator: manufacturing optimization. In: 2016 IEEE SENSORS. IEEE, pp 1–3
31.
go back to reference Sefati S, Pozin M, Alambeigi F, Iordachita I, Taylor RH, Armand M (2017) A highly sensitive fiber Bragg Grating shape sensor for continuum manipulators with large deflections. In: 2017 IEEE SENSORS. IEEE, pp 1–3 Sefati S, Pozin M, Alambeigi F, Iordachita I, Taylor RH, Armand M (2017) A highly sensitive fiber Bragg Grating shape sensor for continuum manipulators with large deflections. In: 2017 IEEE SENSORS. IEEE, pp 1–3
32.
go back to reference Starr A, Jones A, Reinert C, Borer D (2001) Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum. Injury 32:SA45–50CrossRefPubMed Starr A, Jones A, Reinert C, Borer D (2001) Preliminary results and complications following limited open reduction and percutaneous screw fixation of displaced fractures of the acetabulum. Injury 32:SA45–50CrossRefPubMed
33.
go back to reference Suzuki T, Soma K, Shindo M, Minehara H, Itoman M (2008) Anatomic study for pubic medullary screw insertion. J Orthop Surg 16(3):321–325CrossRef Suzuki T, Soma K, Shindo M, Minehara H, Itoman M (2008) Anatomic study for pubic medullary screw insertion. J Orthop Surg 16(3):321–325CrossRef
34.
go back to reference Synowitz M, Kiwit J (2006) Surgeons radiation exposure during percutaneous vertebroplasty. J Neurosurg Spine 4(2):106–109CrossRefPubMed Synowitz M, Kiwit J (2006) Surgeons radiation exposure during percutaneous vertebroplasty. J Neurosurg Spine 4(2):106–109CrossRefPubMed
35.
go back to reference Theocharopoulos N, Perisinakis K, Damilakis J, Papadokostakis G, Hadjipavlou A, Gourtsoyiannis N (2003) Occupational exposure from common fluoroscopic projections used in orthopaedic surgery. JBJS 85(9):1698–1703CrossRef Theocharopoulos N, Perisinakis K, Damilakis J, Papadokostakis G, Hadjipavlou A, Gourtsoyiannis N (2003) Occupational exposure from common fluoroscopic projections used in orthopaedic surgery. JBJS 85(9):1698–1703CrossRef
36.
go back to reference Theologis A, Burch S, Pekmezci M (2016) Placement of iliosacral screws using 3d image-guided (O-arm) technology and stealth navigation: comparison with traditional fluoroscopy. Bone Joint J 98(5):696–702CrossRefPubMed Theologis A, Burch S, Pekmezci M (2016) Placement of iliosacral screws using 3d image-guided (O-arm) technology and stealth navigation: comparison with traditional fluoroscopy. Bone Joint J 98(5):696–702CrossRefPubMed
37.
38.
go back to reference Tsai RY, Lenz RK (1989) A new technique for fully autonomous and efficient 3d robotics hand/eye calibration. IEEE Trans Robot Autom 5(3):345–358CrossRef Tsai RY, Lenz RK (1989) A new technique for fully autonomous and efficient 3d robotics hand/eye calibration. IEEE Trans Robot Autom 5(3):345–358CrossRef
39.
go back to reference Tucker E, Fotouhi J, Unberath M, Lee SC, Fuerst B, Johnson A, Armand M, Osgood GM, Navab N (2018) Towards clinical translation of augmented orthopedic surgery: from pre-op ct to intra-op x-ray via RGBD sensing. In: Medical imaging 2018: imaging informatics for healthcare, research, and applications, vol 10579. International Society for Optics and Photonics, p 105790J Tucker E, Fotouhi J, Unberath M, Lee SC, Fuerst B, Johnson A, Armand M, Osgood GM, Navab N (2018) Towards clinical translation of augmented orthopedic surgery: from pre-op ct to intra-op x-ray via RGBD sensing. In: Medical imaging 2018: imaging informatics for healthcare, research, and applications, vol 10579. International Society for Optics and Photonics, p 105790J
40.
go back to reference Unberath M, Fotouhi J, Hajek J, Maier A, Osgood G, Taylor R, Armand M, Navab N (2018) Augmented reality-based feedback for technician-in-the-loop C-arm repositioning. Healthc Technol Lett 5:143–147CrossRefPubMedPubMedCentral Unberath M, Fotouhi J, Hajek J, Maier A, Osgood G, Taylor R, Armand M, Navab N (2018) Augmented reality-based feedback for technician-in-the-loop C-arm repositioning. Healthc Technol Lett 5:143–147CrossRefPubMedPubMedCentral
41.
go back to reference Vorraber W, Voessner S, Stark G, Neubacher D, DeMello S, Bair A (2014) Medical applications of near-eye display devices: an exploratory study. Int J Surg 12(12):1266–1272CrossRefPubMed Vorraber W, Voessner S, Stark G, Neubacher D, DeMello S, Bair A (2014) Medical applications of near-eye display devices: an exploratory study. Int J Surg 12(12):1266–1272CrossRefPubMed
42.
go back to reference Yoon JW, Chen RE, Han PK, Si P, Freeman WD, Pirris SM (2016) Technical feasibility and safety of an intraoperative head-up display device during spine instrumentation. Int J Med Robot Comput Assist Surg 13:e1770CrossRef Yoon JW, Chen RE, Han PK, Si P, Freeman WD, Pirris SM (2016) Technical feasibility and safety of an intraoperative head-up display device during spine instrumentation. Int J Med Robot Comput Assist Surg 13:e1770CrossRef
Metadata
Title
Interactive Flying Frustums (IFFs): spatially aware surgical data visualization
Authors
Javad Fotouhi
Mathias Unberath
Tianyu Song
Wenhao Gu
Alex Johnson
Greg Osgood
Mehran Armand
Nassir Navab
Publication date
01-06-2019
Publisher
Springer International Publishing
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 6/2019
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-019-01943-z

Other articles of this Issue 6/2019

International Journal of Computer Assisted Radiology and Surgery 6/2019 Go to the issue