Abstract

Purpose

Surgical robots with cooperative control and semiautonomous features have shown increasing clinical potential, particularly for repetitive tasks under imaging and vision guidance. Effective performance of an autonomous task requires accurate hand–eye calibration so that the transformation between the robot coordinate frame and the camera coordinates is well defined. In practice, due to changes in surgical instruments, online hand–eye calibration must be performed regularly. In order to ensure seamless execution of the surgical procedure without affecting the normal surgical workflow, it is important to derive fast and efficient hand–eye calibration methods.

Methods

We present a computationally efficient iterative method for hand–eye calibration. In this method, dual quaternion is introduced to represent the rigid transformation, and a two-step iterative method is proposed to recover the real and dual parts of the dual quaternion simultaneously, and thus the estimation of rotation and translation of the transformation.

Results

The proposed method was applied to determine the rigid transformation between the stereo laparoscope and the robot manipulator. Promising experimental and simulation results have shown significant convergence speed improvement to 3 iterations from larger than 30 with regard to standard optimization method, which illustrates the effectiveness and efficiency of the proposed method.
Literature
1.
go back to reference Bergeles C, Yang G-Z (2014) From passive tool holders to microsurgeons: safer, smaller, smarter surgical robots. IEEE Trans Biomed Eng 61(5):1565–1576CrossRefPubMed Bergeles C, Yang G-Z (2014) From passive tool holders to microsurgeons: safer, smaller, smarter surgical robots. IEEE Trans Biomed Eng 61(5):1565–1576CrossRefPubMed
2.
go back to reference Du X, Allan M, Dore A, Ourselin S, Hawkes D, Kelly JD, Stoyanov D (2016) Combined 2D and 3D tracking of surgical instruments for minimally invasive and robotic-assisted surgery. Int J Comput Assist Radiol Surg 11(6):1109–1119CrossRefPubMedPubMedCentral Du X, Allan M, Dore A, Ourselin S, Hawkes D, Kelly JD, Stoyanov D (2016) Combined 2D and 3D tracking of surgical instruments for minimally invasive and robotic-assisted surgery. Int J Comput Assist Radiol Surg 11(6):1109–1119CrossRefPubMedPubMedCentral
3.
go back to reference Fard MJ, Ameri S, Chinnam RB, Ellis RD (2017) Soft boundary approach for unsupervised gesture segmentation in robotic-assisted surgery. IEEE Robot Automation Lett 2(1):171–178CrossRef Fard MJ, Ameri S, Chinnam RB, Ellis RD (2017) Soft boundary approach for unsupervised gesture segmentation in robotic-assisted surgery. IEEE Robot Automation Lett 2(1):171–178CrossRef
4.
go back to reference Herrell SD, Galloway RL Jr, Miga MI (2015) Image guidance in robotic-assisted renal surgery. In: Liao JC, Su L-M (eds) Advances in image-guided urologic surgery. Springer, Berlin, pp 221–241 Herrell SD, Galloway RL Jr, Miga MI (2015) Image guidance in robotic-assisted renal surgery. In: Liao JC, Su L-M (eds) Advances in image-guided urologic surgery. Springer, Berlin, pp 221–241
5.
go back to reference Nadeau C, Krupa A (2013) Intensity-based ultrasound visual servoing: modeling and validation with 2-D and 3-D probes. IEEE Trans Robot 29(4):1003–1015CrossRef Nadeau C, Krupa A (2013) Intensity-based ultrasound visual servoing: modeling and validation with 2-D and 3-D probes. IEEE Trans Robot 29(4):1003–1015CrossRef
6.
go back to reference Vitiello V, Lee S-L, Cundy TP, Yang G-Z (2013) Emerging robotic platforms for minimally invasive surgery. IEEE Rev Biomed Eng 6:111–126CrossRefPubMed Vitiello V, Lee S-L, Cundy TP, Yang G-Z (2013) Emerging robotic platforms for minimally invasive surgery. IEEE Rev Biomed Eng 6:111–126CrossRefPubMed
7.
8.
go back to reference Nadeau C, Ren H, Krupa A, Dupont P (2015) Intensity-based visual servoing for instrument and tissue tracking in 3D ultrasound volumes. IEEE Trans Automation Sci Eng 12(1):367–371CrossRef Nadeau C, Ren H, Krupa A, Dupont P (2015) Intensity-based visual servoing for instrument and tissue tracking in 3D ultrasound volumes. IEEE Trans Automation Sci Eng 12(1):367–371CrossRef
9.
go back to reference Miga MI (2016) Computational modeling for enhancing soft tissue image guided surgery: an application in neurosurgery. Ann Biomed Eng 44(1):128–138CrossRefPubMed Miga MI (2016) Computational modeling for enhancing soft tissue image guided surgery: an application in neurosurgery. Ann Biomed Eng 44(1):128–138CrossRefPubMed
10.
go back to reference Shiu YC, Ahmad S (1989) Calibration of wrist-mounted robotic sensors by solving homogeneous transform equations of the form ax = xb. IEEE Trans Robot Automation 5(1):16–29CrossRef Shiu YC, Ahmad S (1989) Calibration of wrist-mounted robotic sensors by solving homogeneous transform equations of the form ax = xb. IEEE Trans Robot Automation 5(1):16–29CrossRef
11.
go back to reference Park FC, Martin BJ (1994) Robot sensor calibration: solving ax = xb on the euclidean group. IEEE Trans Robot Automation 10(5):717CrossRef Park FC, Martin BJ (1994) Robot sensor calibration: solving ax = xb on the euclidean group. IEEE Trans Robot Automation 10(5):717CrossRef
12.
go back to reference Chou JC, Kamel M (1991) Finding the position and orientation of a sensor on a robot manipulator using quaternions. Int J Robot Res 10(3):240–254CrossRef Chou JC, Kamel M (1991) Finding the position and orientation of a sensor on a robot manipulator using quaternions. Int J Robot Res 10(3):240–254CrossRef
13.
go back to reference Liang R-h, Mao J-F (2008) Hand–eye calibration with a new linear decomposition algorithm. J Zhejiang Univ Sci A 9(10):1363–1368CrossRef Liang R-h, Mao J-F (2008) Hand–eye calibration with a new linear decomposition algorithm. J Zhejiang Univ Sci A 9(10):1363–1368CrossRef
14.
go back to reference Pan H, Wang NL, Qin YS (2014) A closed-form solution to eye-to-hand calibration towards visual grasping. Ind Robot Int J 41(6):567–574CrossRef Pan H, Wang NL, Qin YS (2014) A closed-form solution to eye-to-hand calibration towards visual grasping. Ind Robot Int J 41(6):567–574CrossRef
15.
go back to reference Najafi M, Afsham N, Abolmaesumi P, Rohling R (2014) A closed-form differential formulation for ultrasound spatial calibration: multi-wedge phantom. Ultrasound Med Biol 40(9):2231–2243CrossRefPubMed Najafi M, Afsham N, Abolmaesumi P, Rohling R (2014) A closed-form differential formulation for ultrasound spatial calibration: multi-wedge phantom. Ultrasound Med Biol 40(9):2231–2243CrossRefPubMed
16.
go back to reference Lu Y-C, Chou JC (1995) Eight-space quaternion approach for robotic hand–eye calibration. In: Systems, man and cybernetics. IEEE international conference on intelligent systems for the 21st century, vol 4. IEEE, pp 3316–3321 Lu Y-C, Chou JC (1995) Eight-space quaternion approach for robotic hand–eye calibration. In: Systems, man and cybernetics. IEEE international conference on intelligent systems for the 21st century, vol 4. IEEE, pp 3316–3321
17.
go back to reference Daniilidis K (1999) Hand–eye calibration using dual quaternions. Int J Robot Res 18(3):286–298CrossRef Daniilidis K (1999) Hand–eye calibration using dual quaternions. Int J Robot Res 18(3):286–298CrossRef
18.
go back to reference Zhao Z, Liu Y (2009) A hand-eye calibration algorithm based on screw motions. Robotica 27(02):217–223CrossRef Zhao Z, Liu Y (2009) A hand-eye calibration algorithm based on screw motions. Robotica 27(02):217–223CrossRef
19.
go back to reference Andreff N, Horaud R, Espiau B (1999) On-line hand–eye calibration. In: 3-D Digital Imaging and Modeling, 1999. Proceedings. Second International Conference on. IEEE, pp. 430–436 Andreff N, Horaud R, Espiau B (1999) On-line hand–eye calibration. In: 3-D Digital Imaging and Modeling, 1999. Proceedings. Second International Conference on. IEEE, pp. 430–436
20.
go back to reference Schmidt J, Vogt F, Niemann H (2003) Robust hand-eye calibration of an endoscopic surgery robot using dual quaternions. In: Joint pattern recognition symposium. Springer, pp 548–556 Schmidt J, Vogt F, Niemann H (2003) Robust hand-eye calibration of an endoscopic surgery robot using dual quaternions. In: Joint pattern recognition symposium. Springer, pp 548–556
21.
go back to reference Strobl KH, Hirzinger G (2006) Optimal hand–eye calibration. In: IEEE/RSJ international conference on intelligent robots and systems. IEEE, pp 4647–4653 Strobl KH, Hirzinger G (2006) Optimal hand–eye calibration. In: IEEE/RSJ international conference on intelligent robots and systems. IEEE, pp 4647–4653
22.
go back to reference Mao J, Huang X, Jiang L (2010) A flexible solution to ax = xb for robot hand–eye calibration. In: Proceedings of the 10th WSEAS international conference on Robotics, control and manufacturing technology. World Scientific and Engineering Academy and Society (WSEAS), pp 118–122 Mao J, Huang X, Jiang L (2010) A flexible solution to ax = xb for robot hand–eye calibration. In: Proceedings of the 10th WSEAS international conference on Robotics, control and manufacturing technology. World Scientific and Engineering Academy and Society (WSEAS), pp 118–122
23.
go back to reference Zhao Z (2011) Hand–eye calibration using convex optimization. In: 2011 IEEE international conference on robotics and automation (ICRA). IEEE, pp 2947–2952 Zhao Z (2011) Hand–eye calibration using convex optimization. In: 2011 IEEE international conference on robotics and automation (ICRA). IEEE, pp 2947–2952
24.
go back to reference Ruland T, Pajdla T, Kruger L (2012) Globally optimal hand–eye calibration. In: 2012 IEEE conference on computer vision and pattern recognition (CVPR), pp 1035–1042 Ruland T, Pajdla T, Kruger L (2012) Globally optimal hand–eye calibration. In: 2012 IEEE conference on computer vision and pattern recognition (CVPR), pp 1035–1042
25.
go back to reference Ackerman MK, Cheng A, Boctor E, Chirikjian G (2014) Online ultrasound sensor calibration using gradient descent on the euclidean group. In: 2014 IEEE international conference on robotics and automation (ICRA). IEEE, pp 4900–4905 Ackerman MK, Cheng A, Boctor E, Chirikjian G (2014) Online ultrasound sensor calibration using gradient descent on the euclidean group. In: 2014 IEEE international conference on robotics and automation (ICRA). IEEE, pp 4900–4905
26.
go back to reference Heller J, Henrion D, Pajdla T (2014) Hand–eye and robot-world calibration by global polynomial optimization. In: 2014 IEEE international conference on robotics and automation (ICRA), pp 3157–3164 Heller J, Henrion D, Pajdla T (2014) Hand–eye and robot-world calibration by global polynomial optimization. In: 2014 IEEE international conference on robotics and automation (ICRA), pp 3157–3164
27.
go back to reference Heller J, Havlena M, Pajdla T (2016) Globally optimal hand–eye calibration using branch-and-bound. IEEE Trans Pattern Anal Mach Intell 38(5):1027–1033CrossRefPubMed Heller J, Havlena M, Pajdla T (2016) Globally optimal hand–eye calibration using branch-and-bound. IEEE Trans Pattern Anal Mach Intell 38(5):1027–1033CrossRefPubMed
28.
go back to reference Wu H, Tizzano W, Andersen TT, Andersen NA, Ravn O (2014) Hand–eye calibration and inverse kinematics of robot arm using neural network. In: Kim J-H, Matson ET, Myung H, Xu P, Karry F (eds) Robot intelligence technology and applications 2. Springer, Berlin, pp 581–591 Wu H, Tizzano W, Andersen TT, Andersen NA, Ravn O (2014) Hand–eye calibration and inverse kinematics of robot arm using neural network. In: Kim J-H, Matson ET, Myung H, Xu P, Karry F (eds) Robot intelligence technology and applications 2. Springer, Berlin, pp 581–591
29.
go back to reference Sarrazin J, Promayon E, Baumann M, Troccaz J (2015) Hand–eye calibration of a robot-ultrasound probe system without any 3D localizers. In: 2015 37th annual international conference of the IEEE engineering in medicine and biology society (EMBC). IEEE, pp 21–24 Sarrazin J, Promayon E, Baumann M, Troccaz J (2015) Hand–eye calibration of a robot-ultrasound probe system without any 3D localizers. In: 2015 37th annual international conference of the IEEE engineering in medicine and biology society (EMBC). IEEE, pp 21–24
30.
go back to reference Hager WW, Zhang H (2006) A new active set algorithm for box constrained optimization. SIAM J Optim 17(2):526–557CrossRef Hager WW, Zhang H (2006) A new active set algorithm for box constrained optimization. SIAM J Optim 17(2):526–557CrossRef
31.
go back to reference Nemirovski AS, Todd MJ (2008) Interior-point methods for optimization. Acta Numer 17:191–234CrossRef Nemirovski AS, Todd MJ (2008) Interior-point methods for optimization. Acta Numer 17:191–234CrossRef
32.
go back to reference Nocedal J, Wright SJ (2006) Numerical optimization, 2nd edn. Springer Series in Operations Research and Financial Engineering, Springer, New York Nocedal J, Wright SJ (2006) Numerical optimization, 2nd edn. Springer Series in Operations Research and Financial Engineering, Springer, New York
33.
go back to reference Trawny N, Roumeliotis SI (2005) Indirect kalman filter for 3d attitude estimation. University of Minnesota, Department of Computer Science & Engineering, Technical Report, vol 2, p 2005 Trawny N, Roumeliotis SI (2005) Indirect kalman filter for 3d attitude estimation. University of Minnesota, Department of Computer Science & Engineering, Technical Report, vol 2, p 2005
34.
go back to reference Zhang Z, Panousopoulou A, Yang G-Z (2014) Wearable sensor integration and bio-motion capture: a practical perspective. In: Yang G-Z (ed) Body sensor networks. Springer, Berlin, pp 495–526 Zhang Z, Panousopoulou A, Yang G-Z (2014) Wearable sensor integration and bio-motion capture: a practical perspective. In: Yang G-Z (ed) Body sensor networks. Springer, Berlin, pp 495–526
35.
go back to reference Kenwright B (2012) A beginners guide to dual-quaternions: what they are, how they work, and how to use them for 3D character hierarchies. In: 20th international conferences on computer graphics, visualization and computer vision, pp 1–10 Kenwright B (2012) A beginners guide to dual-quaternions: what they are, how they work, and how to use them for 3D character hierarchies. In: 20th international conferences on computer graphics, visualization and computer vision, pp 1–10
36.
go back to reference Moler CB (2004) Least squares. In: Numerical computing with Matlab, chapter 5. Society for Industrial and Applied Mathematics, pp 139–163 Moler CB (2004) Least squares. In: Numerical computing with Matlab, chapter 5. Society for Industrial and Applied Mathematics, pp 139–163
37.
go back to reference Ballantyne GH, Moll F (2003) The da vinci telerobotic surgical system: the virtual operative field and telepresence surgery. Surg Clin N Am 83(6):1293–1304 Ballantyne GH, Moll F (2003) The da vinci telerobotic surgical system: the virtual operative field and telepresence surgery. Surg Clin N Am 83(6):1293–1304
38.
go back to reference Chen Z, Deguet A, Taylor R, DiMaio S, Fischer G, Kazanzides P (2013) An open-source hardware and software platform for telesurgical robotics research. In: Proceedings of the MICCAI workshop on systems and architecture for computer assisted interventions, Nagoya, pp 22–26 Chen Z, Deguet A, Taylor R, DiMaio S, Fischer G, Kazanzides P (2013) An open-source hardware and software platform for telesurgical robotics research. In: Proceedings of the MICCAI workshop on systems and architecture for computer assisted interventions, Nagoya, pp 22–26
39.
go back to reference Reiter A, Allen PK, Zhao T (2014) Appearance learning for 3D tracking of robotic surgical tools. Int J Robot Res 33(2):342–356 Reiter A, Allen PK, Zhao T (2014) Appearance learning for 3D tracking of robotic surgical tools. Int J Robot Res 33(2):342–356
40.
go back to reference Zhang L, Ye M, Chan P-L, Yang G-Z (2017) Real-time surgical tool tracking and pose estimation using a hybrid cylindrical marker. Int J Comput Assist Radiol Surg 12(6):921–930 Zhang L, Ye M, Chan P-L, Yang G-Z (2017) Real-time surgical tool tracking and pose estimation using a hybrid cylindrical marker. Int J Comput Assist Radiol Surg 12(6):921–930
41.
go back to reference Pachtrachai K, Allan M, Pawar V, Hailes S, Stoyanov D (2016) Hand–eye calibration for robotic assisted minimally invasive surgery without a calibration object. In: 2016 IEEE/RSJ international conference on intelligent robots and systems (IROS). IEEE, pp 2485–2491 Pachtrachai K, Allan M, Pawar V, Hailes S, Stoyanov D (2016) Hand–eye calibration for robotic assisted minimally invasive surgery without a calibration object. In: 2016 IEEE/RSJ international conference on intelligent robots and systems (IROS). IEEE, pp 2485–2491
Metadata
Title
A computationally efficient method for hand–eye calibration
Authors
Zhiqiang Zhang
Lin Zhang
Guang-Zhong Yang
Publication date
01-10-2017
Publisher
Springer International Publishing
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 10/2017
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-017-1646-x

Other articles of this Issue 10/2017

International Journal of Computer Assisted Radiology and Surgery 10/2017 Go to the issue