Abstract

Purpose

An accurate fit of a patient-specific instrument guide during an intervention is one of the critical factors affecting accuracy of the surgical procedure. In this study, we investigated how well osteophytes, which are abnormal bone growths that form along joints, are depicted in clinical preoperative CT scans and estimated the influence of such depiction errors on the intraoperative accuracy of the guide.

Methods

In 34 hip resurfacing patients, 227 osteophyte surface points on the anterior aspect of the femoral neck were collected intraoperatively, using an optoelectronic navigation system. These points were registered to a preoperative CT scan of the patient, and distances between collected points and segmented virtual bone surface, as well as Hounsfield units for these points, were determined. We simulated the registration error of a patient-specific guide, using a modified registration algorithm, to test placement on the anterior aspect of the femoral neck without removing any osteophytes. This error was then applied to the surgical plan of the femoral central-pin position and orientation for evaluation.

Results

The average distance between the collected points and the segmented surface was 2.6 mm. We estimated the average error for the entrance point of the central-pin to be 0.7 mm in the distal direction and 3.2 mm in the anterior direction. The average orientation error was \(2.8^\circ \) in anteversion.

Conclusions

The depiction of osteophytes in clinical preoperative CT scans for proximal femurs can be unreliable and can possibly result in significant intraoperative instrument alignment errors during image-guided surgeries.
Literature
1.
go back to reference Radermacher K, Portheine F, Anton M, Zimolong A, Kaspers G, Rau G, Staudte HW (1998) Computer assisted orthopaedic surgery with image based individual templates. Clin Orthop Relat Res 354:28–38CrossRefPubMed Radermacher K, Portheine F, Anton M, Zimolong A, Kaspers G, Rau G, Staudte HW (1998) Computer assisted orthopaedic surgery with image based individual templates. Clin Orthop Relat Res 354:28–38CrossRefPubMed
2.
go back to reference Putzier M, Strube P, Cecchinato R, Lamartina C, Hoff E (2014) A new navigational tool for pedicle screw placement in patients with severe scoliosis: a pilot study to prove feasibility, accuracy, and identify operative challenges. J Spinal Disord Tech [Epub ahead of print] Putzier M, Strube P, Cecchinato R, Lamartina C, Hoff E (2014) A new navigational tool for pedicle screw placement in patients with severe scoliosis: a pilot study to prove feasibility, accuracy, and identify operative challenges. J Spinal Disord Tech [Epub ahead of print]
8.
go back to reference Sakai T, Hanada T, Murase T, Kitada M, Hamada H, Yoshikawa H, Sugano N (2014) Validation of patient specific surgical guides in total hip arthroplasty. Int J Med Robot 10(1):113–120. doi:10.1002/rcs.1547 CrossRefPubMed Sakai T, Hanada T, Murase T, Kitada M, Hamada H, Yoshikawa H, Sugano N (2014) Validation of patient specific surgical guides in total hip arthroplasty. Int J Med Robot 10(1):113–120. doi:10.​1002/​rcs.​1547 CrossRefPubMed
13.
go back to reference Walch G, Vezeridis PS, Boileau P, Deransart P, Chaoui J (2014) Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study. J Shoulder Elb Surg. doi:10.1016/j.jse.2014.05.029 Walch G, Vezeridis PS, Boileau P, Deransart P, Chaoui J (2014) Three-dimensional planning and use of patient-specific guides improve glenoid component position: an in vitro study. J Shoulder Elb Surg. doi:10.​1016/​j.​jse.​2014.​05.​029
14.
go back to reference Leeuwen JA, Grøgaard B, Nordsletten L, Röhrl SM (2014) Comparison of planned and achieved implant position in total knee arthroplasty with patient-specific positioning guides. Acta Orthop 11:1–6 Leeuwen JA, Grøgaard B, Nordsletten L, Röhrl SM (2014) Comparison of planned and achieved implant position in total knee arthroplasty with patient-specific positioning guides. Acta Orthop 11:1–6
15.
go back to reference Cavaignac E, Pailhé R, Laumond G, Murgier J, Reina N, Laffosse JM, Bérard E, Chiron P (2014) Evaluation of the accuracy of patient-specific cutting blocks for total knee arthroplasty: a meta-analysis. Int Orthop [Epub ahead of print] Cavaignac E, Pailhé R, Laumond G, Murgier J, Reina N, Laffosse JM, Bérard E, Chiron P (2014) Evaluation of the accuracy of patient-specific cutting blocks for total knee arthroplasty: a meta-analysis. Int Orthop [Epub ahead of print]
16.
go back to reference Voleti PB, Hamula MJ, Baldwin KD, Lee GC (2014) Current data do not support routine use of patient-specific instrumentation in total knee arthroplasty. J Arthroplasty 29(9):1709–1712. doi:10.1016/j.arth.2014.01.039 Voleti PB, Hamula MJ, Baldwin KD, Lee GC (2014) Current data do not support routine use of patient-specific instrumentation in total knee arthroplasty. J Arthroplasty 29(9):1709–1712. doi:10.​1016/​j.​arth.​2014.​01.​039
17.
go back to reference Turmezei TD, Poole KE (2011) Computed tomography of subchrondral bone and osteophytes in hip osteoarthritis: the shape of things to come? Front Endocrinol (Lausanne) 13(2):97. doi:10.3389/fendo.2011.00097 Turmezei TD, Poole KE (2011) Computed tomography of subchrondral bone and osteophytes in hip osteoarthritis: the shape of things to come? Front Endocrinol (Lausanne) 13(2):97. doi:10.​3389/​fendo.​2011.​00097
18.
go back to reference Gelse K, Soeder S, Eger W, Dietmar T, Aigner T (2003) Osteophyte development—molecular characterization of different stages. Osteoarthr Cartil 11(2):141–148CrossRefPubMed Gelse K, Soeder S, Eger W, Dietmar T, Aigner T (2003) Osteophyte development—molecular characterization of different stages. Osteoarthr Cartil 11(2):141–148CrossRefPubMed
19.
go back to reference Seon J-K, Park H-W, Yoo S-H, Song E-K (2014) Assessing the accuracy of patient-specific guides for total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc [Epub ahead of print] Seon J-K, Park H-W, Yoo S-H, Song E-K (2014) Assessing the accuracy of patient-specific guides for total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc [Epub ahead of print]
20.
go back to reference Kunz M, Rudan JF, Wood GC, Ellis RE (2011) Registration stability of physical templates in hip surgery. Stud Health Technol Inform 163:283–289PubMed Kunz M, Rudan JF, Wood GC, Ellis RE (2011) Registration stability of physical templates in hip surgery. Stud Health Technol Inform 163:283–289PubMed
23.
go back to reference Horn BKP (1987) Closed form solution of absolute orientation using unit quaternions. J Opt Soc Am A 4(44):629–642CrossRef Horn BKP (1987) Closed form solution of absolute orientation using unit quaternions. J Opt Soc Am A 4(44):629–642CrossRef
24.
go back to reference Amstutz HC, Campbell PA, Le Duff MJ (2004) Fracture of the neck of the femur after surface arthroplasty of the hip. J Bone Joint Surg 86–A(9):1874–1877PubMed Amstutz HC, Campbell PA, Le Duff MJ (2004) Fracture of the neck of the femur after surface arthroplasty of the hip. J Bone Joint Surg 86–A(9):1874–1877PubMed
25.
go back to reference Siebel T, Maubach S, Morlock MM (2006) Lessons learned from early clinical experience and results of 300 ASR hip resurfacing implantations. Proc Inst Mech Eng [H] 220(2):345–353CrossRef Siebel T, Maubach S, Morlock MM (2006) Lessons learned from early clinical experience and results of 300 ASR hip resurfacing implantations. Proc Inst Mech Eng [H] 220(2):345–353CrossRef
27.
go back to reference Paz ME, Carter LC, Westesson P-L, Katzberg RW, Tallents R, Subtelny D, Goldin B (1990) CT density of the TMJ disk: correlation with histologic observations of hyalinization, metaplastic cartilage, and calcification in autopsy specimens. Am J Orthopd Dento Fac Orthop 98:354–357CrossRef Paz ME, Carter LC, Westesson P-L, Katzberg RW, Tallents R, Subtelny D, Goldin B (1990) CT density of the TMJ disk: correlation with histologic observations of hyalinization, metaplastic cartilage, and calcification in autopsy specimens. Am J Orthopd Dento Fac Orthop 98:354–357CrossRef
28.
go back to reference Baxter BS, Sorenson JA (1981) Factors affecting the measurement of size and CT number in computed tomography. Invest Radiol 16:337–341CrossRefPubMed Baxter BS, Sorenson JA (1981) Factors affecting the measurement of size and CT number in computed tomography. Invest Radiol 16:337–341CrossRefPubMed
Metadata
Title
The influence of osteophyte depiction in CT for patient-specific guided hip resurfacing procedures
Authors
M. Kunz
S. Balaketheeswaran
R. E. Ellis
J. F. Rudan
Publication date
01-06-2015
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 6/2015
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-015-1200-7

Other articles of this Issue 6/2015

International Journal of Computer Assisted Radiology and Surgery 6/2015 Go to the issue