Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 4/2014

01-07-2014 | Original Article

Deformable image registration for temporal subtraction of chest radiographs

Authors: Min Li, Edward Castillo, Hong-Yan Luo, Xiao-Lin Zheng, Richard Castillo, Dmitriy Meshkov, Thomas Guerrero

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 4/2014

Login to get access

Abstract

Purpose

Temporal subtraction images constructed from image registration can facilitate the visualization of pathologic changes. In this study, we propose a deformable image registration (DIR) framework for creating temporal subtraction images of chest radiographs.

Methods

We developed a DIR methodology using two different image similarity metrics, varying flow (VF) and compressible flow (CF). The proposed registration method consists of block matching, filtering, and interpolation. Specifically, corresponding point pairs between reference and target images are initially determined by minimizing a nonlinear least squares formulation using grid-searching optimization. A two-step filtering process, including least median of squares filtering and backward matching filtering, is then applied to the estimated point matches in order to remove erroneous matches. Finally, moving least squares is used to generate a full displacement field from the filtered point pairs.

Results

We applied the proposed DIR method to 10 pairs of clinical chest radiographs and compared it with the demons and B-spline algorithms using the five-point rating score method. The average quality scores were 2.7 and 3 for the demons and B-spline methods, but 3.5 and 4.1 for the VF and CF methods. In addition, subtraction images improved the visual perception of abnormalities in the lungs by using the proposed method.

Conclusion

The VF and CF models achieved a higher accuracy than the demons and the B-spline methods. Furthermore, the proposed methodology demonstrated the ability to create clinically acceptable temporal subtraction chest radiographs that enhance interval changes and can be used to detect abnormalities such as non-small cell lung cancer.
Literature
1.
go back to reference Yu Q, He L, Chao Y, Suzuki K, Nakamura T (2012) A mutual-information-based image registration method for chest-radiograph temporal subtraction. In: Proceedings of CSIP, pp 1098–1101 Yu Q, He L, Chao Y, Suzuki K, Nakamura T (2012) A mutual-information-based image registration method for chest-radiograph temporal subtraction. In: Proceedings of CSIP, pp 1098–1101
2.
go back to reference Ishida T, Katsuragawa S, Nakamura K, MacMahon H, Doi K (1999) Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change. Med Phys 26(7):1320–1329PubMedCrossRef Ishida T, Katsuragawa S, Nakamura K, MacMahon H, Doi K (1999) Iterative image warping technique for temporal subtraction of sequential chest radiographs to detect interval change. Med Phys 26(7):1320–1329PubMedCrossRef
3.
go back to reference Loeckx D, Maes F, Vandermeulen D, Suetens P (2003) Temporal subtraction of thorax CR images using a statistical deformation model. IEEE Trans Med Imaging 22:1490–1504PubMedCrossRef Loeckx D, Maes F, Vandermeulen D, Suetens P (2003) Temporal subtraction of thorax CR images using a statistical deformation model. IEEE Trans Med Imaging 22:1490–1504PubMedCrossRef
4.
go back to reference McAdams HP, Samei E, Dobbins J III, Tourassi GD, Ravin CE (2006) Recent advances in chest radiography. Radiology 241:663–683PubMedCrossRef McAdams HP, Samei E, Dobbins J III, Tourassi GD, Ravin CE (2006) Recent advances in chest radiography. Radiology 241:663–683PubMedCrossRef
5.
go back to reference Yang J, Wang Y, Tang S, Zhou S, Liu Y, Chen W (2007) Multiresolution elastic registration of X-ray angiography images using thin-plate spline. IEEE Trans Nucl Sci 54(1):152–166CrossRef Yang J, Wang Y, Tang S, Zhou S, Liu Y, Chen W (2007) Multiresolution elastic registration of X-ray angiography images using thin-plate spline. IEEE Trans Nucl Sci 54(1):152–166CrossRef
6.
go back to reference Yin Y, Hoffman EA, Lin CL (2009) Local tissue-weight-based nonrigid registration of lung images with application to regional ventilation. In: Proceedings of SPIE, vol 7262, p 72620C Yin Y, Hoffman EA, Lin CL (2009) Local tissue-weight-based nonrigid registration of lung images with application to regional ventilation. In: Proceedings of SPIE, vol 7262, p 72620C
7.
go back to reference Gorbunova V, Sporring J, Lo P, Loeve M, Tiddens HA, Nielsen M, Dirksen A, de Bruijne M (2012) Mass preserving image registration for lung CT. Med Image Anal 16(4):786–795PubMedCrossRef Gorbunova V, Sporring J, Lo P, Loeve M, Tiddens HA, Nielsen M, Dirksen A, de Bruijne M (2012) Mass preserving image registration for lung CT. Med Image Anal 16(4):786–795PubMedCrossRef
8.
go back to reference Castillo E, Castillo R, Zhang Y, Guerrero T (2009) Compressible image registration for thoracic computed tomography images. J Med Biol Eng 29(5):222–233 Castillo E, Castillo R, Zhang Y, Guerrero T (2009) Compressible image registration for thoracic computed tomography images. J Med Biol Eng 29(5):222–233
9.
go back to reference Kano A, Doi K, MacMahon H, Hassell DD, Giger ML (1994) Digital image subtraction of temporally sequential chest images for detection of interval change. Med Phys 21(3):453–461 Kano A, Doi K, MacMahon H, Hassell DD, Giger ML (1994) Digital image subtraction of temporally sequential chest images for detection of interval change. Med Phys 21(3):453–461
10.
go back to reference Okazaki H, Nakamura K, Watanabe H, Matsuki Y, Uozumi T, Kakeda K, Oda N, Nakata H, Katsuragawa S, Doi K (2004) Improved detection of lung cancer arising in diffuse lung diseases on chest radiographs using temporal subtraction. Acad Radiol 11(5):498–505 PubMedCrossRef Okazaki H, Nakamura K, Watanabe H, Matsuki Y, Uozumi T, Kakeda K, Oda N, Nakata H, Katsuragawa S, Doi K (2004) Improved detection of lung cancer arising in diffuse lung diseases on chest radiographs using temporal subtraction. Acad Radiol 11(5):498–505 PubMedCrossRef
11.
go back to reference Armato SG, Doshi DJ, Engelmann R, Caligiuri P, MacMahon H (2006) Temporal subtraction of dual-energy chest radiographs. Med Phys 3(6):1911–1919CrossRef Armato SG, Doshi DJ, Engelmann R, Caligiuri P, MacMahon H (2006) Temporal subtraction of dual-energy chest radiographs. Med Phys 3(6):1911–1919CrossRef
12.
go back to reference Aoki T, Oda N, Yamashita Y, Yamamoto K, Korogi Y (2012) Usefulness of computerized method for lung nodule detection on digital chest radiographs using similar subtraction images from different patients. Eur J Radiol 81:1062–1067PubMedCrossRef Aoki T, Oda N, Yamashita Y, Yamamoto K, Korogi Y (2012) Usefulness of computerized method for lung nodule detection on digital chest radiographs using similar subtraction images from different patients. Eur J Radiol 81:1062–1067PubMedCrossRef
13.
go back to reference Inaba T, He L, Suzuki K, Murakami K, Chao Y (2009) A genetic-algorithm-based temporal subtraction for chest radiographs. J Adv Comput Intell Intell Inf 13:289–296 Inaba T, He L, Suzuki K, Murakami K, Chao Y (2009) A genetic-algorithm-based temporal subtraction for chest radiographs. J Adv Comput Intell Intell Inf 13:289–296
14.
go back to reference Guo S, Wu X, Luo Z (2008) Automatic extraction of control points for chest X-ray images and elastic registration. In: Proceedings of ICBBE, pp 2651–2654 Guo S, Wu X, Luo Z (2008) Automatic extraction of control points for chest X-ray images and elastic registration. In: Proceedings of ICBBE, pp 2651–2654
15.
go back to reference Christensen GE, Rabbitt RD, Miller MI (1994) 3D brain mapping using deformable neuroanatomy. Phys Med Biol 39:609–618PubMedCrossRef Christensen GE, Rabbitt RD, Miller MI (1994) 3D brain mapping using deformable neuroanatomy. Phys Med Biol 39:609–618PubMedCrossRef
16.
go back to reference Castillo E, Castillo R, White B, Rojo J, Guerrero T (2012) Least median of squares filtering of locally optimal point matches for compressible flow image registration. Phys Med Biol 57:4827–4833PubMedCentralPubMedCrossRef Castillo E, Castillo R, White B, Rojo J, Guerrero T (2012) Least median of squares filtering of locally optimal point matches for compressible flow image registration. Phys Med Biol 57:4827–4833PubMedCentralPubMedCrossRef
17.
go back to reference Castillo E, Castillo R, Martinez J, Shenoy M, Guerrero T (2010) Four-dimensional deformable image registration using trajectory modeling. Phys Med Biol 55(1):305–327PubMedCentralPubMedCrossRef Castillo E, Castillo R, Martinez J, Shenoy M, Guerrero T (2010) Four-dimensional deformable image registration using trajectory modeling. Phys Med Biol 55(1):305–327PubMedCentralPubMedCrossRef
18.
go back to reference Corpetti T, Memin E, Perez P (2002) Dense estimation of fluid flow. IEEE Trans Pattern Anal Mach Intell 24(3):365–380CrossRef Corpetti T, Memin E, Perez P (2002) Dense estimation of fluid flow. IEEE Trans Pattern Anal Mach Intell 24(3):365–380CrossRef
19.
go back to reference Song SM, Leahy RM (1991) Computation of 3D velocity fields from 3D cine CT images of a human heart. IEEE Trans Med Imaging 10:295–306PubMedCrossRef Song SM, Leahy RM (1991) Computation of 3D velocity fields from 3D cine CT images of a human heart. IEEE Trans Med Imaging 10:295–306PubMedCrossRef
20.
go back to reference Wildes RP, Amabile MJ, Lanzilloto A, Leu T (2000) Recovering estimates of fluid flow from image sequence data. Comput Vis Image Underst 80:246–266 Wildes RP, Amabile MJ, Lanzilloto A, Leu T (2000) Recovering estimates of fluid flow from image sequence data. Comput Vis Image Underst 80:246–266
21.
go back to reference Castillo R, Castillo E, Guerra R, Johnson VE, McPhail T, Garg AK, Guerrero T (2009) A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets. Phys Med Biol 54(7):1849–1870PubMedCrossRef Castillo R, Castillo E, Guerra R, Johnson VE, McPhail T, Garg AK, Guerrero T (2009) A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets. Phys Med Biol 54(7):1849–1870PubMedCrossRef
22.
go back to reference Olsen M, Johnstone E, Kuester F, Driscoll N, Ashford S (2011) New automated point-cloud alignment for ground-based light detection and ranging data of long coastal sections. J Surv Eng 137(1):14–25CrossRef Olsen M, Johnstone E, Kuester F, Driscoll N, Ashford S (2011) New automated point-cloud alignment for ground-based light detection and ranging data of long coastal sections. J Surv Eng 137(1):14–25CrossRef
23.
go back to reference Li Q, Katsuragawa S, Ishida T, Yoshida H, Tsukuda S, MacMahon H, Doi K (2000) Contralateral subtraction: a novel technique for detection of asymmetric abnormalities on digital chest radiographs. Med Phys 27(1):47–55PubMedCrossRef Li Q, Katsuragawa S, Ishida T, Yoshida H, Tsukuda S, MacMahon H, Doi K (2000) Contralateral subtraction: a novel technique for detection of asymmetric abnormalities on digital chest radiographs. Med Phys 27(1):47–55PubMedCrossRef
24.
go back to reference Armato SG, Doshi DJ, Engelmann R, Croteau CL, MacMahon H (2006) Temporal subtraction in chest radiography: automated assessment of registration accuracy. Med Phys 33(5):1239–1249PubMedCrossRef Armato SG, Doshi DJ, Engelmann R, Croteau CL, MacMahon H (2006) Temporal subtraction in chest radiography: automated assessment of registration accuracy. Med Phys 33(5):1239–1249PubMedCrossRef
25.
go back to reference Li Q, Katsuragawa S, Doi K (2000) Improved contralateral subtraction images by use of elastic matching technique. Med Phys 27(8):1934–1942PubMedCrossRef Li Q, Katsuragawa S, Doi K (2000) Improved contralateral subtraction images by use of elastic matching technique. Med Phys 27(8):1934–1942PubMedCrossRef
26.
go back to reference MacMahon H, Armato SG III (2009) Temporal subtraction chest radiography. Eur J Radiol 72(2):238–243PubMedCrossRef MacMahon H, Armato SG III (2009) Temporal subtraction chest radiography. Eur J Radiol 72(2):238–243PubMedCrossRef
Metadata
Title
Deformable image registration for temporal subtraction of chest radiographs
Authors
Min Li
Edward Castillo
Hong-Yan Luo
Xiao-Lin Zheng
Richard Castillo
Dmitriy Meshkov
Thomas Guerrero
Publication date
01-07-2014
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 4/2014
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-013-0947-y

Other articles of this Issue 4/2014

International Journal of Computer Assisted Radiology and Surgery 4/2014 Go to the issue