Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 4/2014

01-07-2014 | Original Article

Three-dimensional prediction of free-flap volume in autologous breast reconstruction by CT angiography imaging

Authors: Maximilian Eder, Stefan Raith, Jalil Jalali, Daniel Müller, Yves Harder, Martin Dobritz, Nikolaos A. Papadopulos, Hans-Günther Machens, Laszlo Kovacs

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 4/2014

Login to get access

Abstract

Purpose

   The diagnostic use of computer tomography angiography (CTA) to identify perforating blood vessels for abdominal free-flap breast reconstruction was extended to estimate the three-dimensional (3D) preoperative flap volume and to compare it with the real intraoperative flap weights in order to (1) evaluate the accuracy of CTA-based 3D flap volume prediction, and (2) to analyze abdominal tissue estimation for required breast volume reconstruction.

Methods

   Preoperative CTA was performed in 54 patients undergoing unilateral breast reconstruction with a free, deep, inferior epigastric artery perforator flap. 3D flap volumes (\(\hbox {cm}^{3}\)) based on CTA data were calculated and compared with the actual intraoperative flap weight (g). In addition, a breast volume to flap volume ratio was calculated to analyze whether the estimated 3D abdominal flap volume would match that of the breast to be removed.

Results

   40 CTA data sets (74.1 %) fulfilled the technical requirements for a reliable determination of flap volume. 3D CTA flap volume prediction showed no relevant differences to the actual flap weight (p = 0.44) and high correlations (r = 0.998, \(p < 0.001\)), allowing a prediction accuracy within 0.29 \(\pm \) 3.0 % (range: from \(-\)8.77 to 5.67 %) of the real flap weight. Significantly larger flap volumes were harvested compared with the actually required breast volumes (\(p < 0.001\)), leading to an average of 21 % of the remnant flap tissue potentially being discarded.

Conclusions

   CTA-based 3D flap volume prediction provides accurate preoperative guidelines concerning the needed amount of abdominal tissue that can be harvested to achieve acceptable symmetry.
Literature
1.
go back to reference Hudson DA (2004) Factors determining shape and symmetry in immediate breast reconstruction. Ann Plast Surg 52:15–21PubMedCrossRef Hudson DA (2004) Factors determining shape and symmetry in immediate breast reconstruction. Ann Plast Surg 52:15–21PubMedCrossRef
2.
go back to reference Kovacs L, Zimmermann A, Papadopulos NA, Biemer E (2004) Re: factors determining shape and symmetry in immediate breast reconstruction. Ann Plast Surg 53:192–194PubMedCrossRef Kovacs L, Zimmermann A, Papadopulos NA, Biemer E (2004) Re: factors determining shape and symmetry in immediate breast reconstruction. Ann Plast Surg 53:192–194PubMedCrossRef
3.
go back to reference Bulstrode N, Bellamy E, Shrotria S (2001) Breast volume assessment: comparing five different techniques. Breast 10:117–123PubMedCrossRef Bulstrode N, Bellamy E, Shrotria S (2001) Breast volume assessment: comparing five different techniques. Breast 10:117–123PubMedCrossRef
4.
go back to reference Kovacs L, Eder M, Hollweck R et al (2007) Comparison between breast volume measurement using 3D surface imaging and classical techniques. Breast 16:137–145PubMedCrossRef Kovacs L, Eder M, Hollweck R et al (2007) Comparison between breast volume measurement using 3D surface imaging and classical techniques. Breast 16:137–145PubMedCrossRef
5.
go back to reference Galdino GM, Nahabedian M, Chiaramonte M et al (2002) Clinical applications of three-dimensional photography in breast surgery. Plast Reconstr Surg 110:58–70PubMedCrossRef Galdino GM, Nahabedian M, Chiaramonte M et al (2002) Clinical applications of three-dimensional photography in breast surgery. Plast Reconstr Surg 110:58–70PubMedCrossRef
6.
go back to reference Losken A, Seify H, Denson DD, Paredes AA Jr, Carlson GW (2005) Validating three dimensional imaging of the breast. Ann Plast Surg 54:471–476PubMedCrossRef Losken A, Seify H, Denson DD, Paredes AA Jr, Carlson GW (2005) Validating three dimensional imaging of the breast. Ann Plast Surg 54:471–476PubMedCrossRef
7.
go back to reference Kovacs L, Eder M, Hollweck R et al (2006) New aspects of breast volume measurement using 3-dimensional surface imaging. Ann Plast Surg 57:602–610PubMedCrossRef Kovacs L, Eder M, Hollweck R et al (2006) New aspects of breast volume measurement using 3-dimensional surface imaging. Ann Plast Surg 57:602–610PubMedCrossRef
8.
go back to reference Eder M, Schneider A, Feussner H et al (2008) Breast volume assessment based on 3D surface geometry: verification of the method using MR imaging. Biomed Tech 53:112–121CrossRef Eder M, Schneider A, Feussner H et al (2008) Breast volume assessment based on 3D surface geometry: verification of the method using MR imaging. Biomed Tech 53:112–121CrossRef
9.
go back to reference Kovacs L, Eder M, Zimmermann A et al (2012) Three-dimensional evaluation of breast augmentation and the influence of anatomic and round implants on operative breast shape changes. Aesthet Plast Surg 36:879–887CrossRef Kovacs L, Eder M, Zimmermann A et al (2012) Three-dimensional evaluation of breast augmentation and the influence of anatomic and round implants on operative breast shape changes. Aesthet Plast Surg 36:879–887CrossRef
10.
go back to reference Eder M, Waldenfels FV, Sichtermann M et al (2011) Three-dimensional evaluation of breast contour and volume changes following subpectoral augmentation mammaplasty over 6 months. J Plast Reconstr Aesthet Surg 64:1152–1160 Eder M, Waldenfels FV, Sichtermann M et al (2011) Three-dimensional evaluation of breast contour and volume changes following subpectoral augmentation mammaplasty over 6 months. J Plast Reconstr Aesthet Surg 64:1152–1160
11.
go back to reference Eder M, Waldenfels FV, Swobodnik A et al (2012) Objective breast symmetry evaluation using 3-D surface imaging. Breast 21:152–158PubMedCrossRef Eder M, Waldenfels FV, Swobodnik A et al (2012) Objective breast symmetry evaluation using 3-D surface imaging. Breast 21:152–158PubMedCrossRef
12.
go back to reference Hokin JA (1983) Mastectomy reconstruction without a prosthetic implant. Plast Reconstr Surg 72:810–818PubMedCrossRef Hokin JA (1983) Mastectomy reconstruction without a prosthetic implant. Plast Reconstr Surg 72:810–818PubMedCrossRef
13.
go back to reference Shamoun JM, Hartrampf CR (1996) Mastectomy specimen weight and skin dimensions as an adjunct to breast reconstruction. Ann Plast Surg 36:251–254PubMedCrossRef Shamoun JM, Hartrampf CR (1996) Mastectomy specimen weight and skin dimensions as an adjunct to breast reconstruction. Ann Plast Surg 36:251–254PubMedCrossRef
14.
go back to reference Mohanna PN, Farhadi J (2012) A method of preoperatively assessing the volume of abdominal tissue available for an autologous breast reconstruction. Plast Reconstr Surg 129:756e–757ePubMedCrossRef Mohanna PN, Farhadi J (2012) A method of preoperatively assessing the volume of abdominal tissue available for an autologous breast reconstruction. Plast Reconstr Surg 129:756e–757ePubMedCrossRef
15.
go back to reference Amir A, Silfen R, Hauben DJ (1999) Use of Archimedes’ law for measuring the volume of the TRAM flap in immediate breast reconstruction. Plast Reconstr Surg 103:1329PubMed Amir A, Silfen R, Hauben DJ (1999) Use of Archimedes’ law for measuring the volume of the TRAM flap in immediate breast reconstruction. Plast Reconstr Surg 103:1329PubMed
16.
go back to reference Lazarus D, Hudson DA (2001) A simple method for determining the weight of the TRAM flap intraoperatively at the time of breast reconstruction. Plast Reconstr Surg 107:818–822PubMedCrossRef Lazarus D, Hudson DA (2001) A simple method for determining the weight of the TRAM flap intraoperatively at the time of breast reconstruction. Plast Reconstr Surg 107:818–822PubMedCrossRef
17.
go back to reference Minn KW, Hong KY, Lee SW (2010) Preoperative TRAM free flap volume estimation for breast reconstruction in lean patients. Ann Plast Surg 64:397–401PubMedCrossRef Minn KW, Hong KY, Lee SW (2010) Preoperative TRAM free flap volume estimation for breast reconstruction in lean patients. Ann Plast Surg 64:397–401PubMedCrossRef
18.
go back to reference Masia J, Kosutic D, Clavero JA et al (2010) Preoperative computed tomographic angiogram for deep inferior epigastric artery perforator flap breast reconstruction. J Reconstr Microsurg 26:21–28PubMedCrossRef Masia J, Kosutic D, Clavero JA et al (2010) Preoperative computed tomographic angiogram for deep inferior epigastric artery perforator flap breast reconstruction. J Reconstr Microsurg 26:21–28PubMedCrossRef
19.
go back to reference Rozen WM, Anavekar NS, Ashton MW et al (2008) Does the preoperative imaging of perforators with CT angiography improve operative outcomes in breast reconstruction? Microsurgery 28:516–523PubMedCrossRef Rozen WM, Anavekar NS, Ashton MW et al (2008) Does the preoperative imaging of perforators with CT angiography improve operative outcomes in breast reconstruction? Microsurgery 28:516–523PubMedCrossRef
20.
go back to reference Smit JM, Dimopoulou A, Liss AG et al (2009) Preoperative CT angiography reduces surgery time in perforator flap reconstruction. J Plast Reconstr Aesthet Surg 62:1112–1117PubMedCrossRef Smit JM, Dimopoulou A, Liss AG et al (2009) Preoperative CT angiography reduces surgery time in perforator flap reconstruction. J Plast Reconstr Aesthet Surg 62:1112–1117PubMedCrossRef
21.
go back to reference Rosson GD, Shridharani SM, Magarakis M et al (2011) Three-dimensional computed tomographic angiography to predict weight and volume of deep inferior epigastric artery perforator flap for breast reconstruction. Microsurgery 31:510–516PubMedCrossRef Rosson GD, Shridharani SM, Magarakis M et al (2011) Three-dimensional computed tomographic angiography to predict weight and volume of deep inferior epigastric artery perforator flap for breast reconstruction. Microsurgery 31:510–516PubMedCrossRef
22.
go back to reference Kim H, Lim SY, Pyon JK, Bang SI, Oh KS, Mun GH (2012) Preoperative computed tomographic angiography of both donor and recipient sites for microsurgical breast reconstruction. Plast Reconstr Surg 130:11–20CrossRef Kim H, Lim SY, Pyon JK, Bang SI, Oh KS, Mun GH (2012) Preoperative computed tomographic angiography of both donor and recipient sites for microsurgical breast reconstruction. Plast Reconstr Surg 130:11–20CrossRef
23.
go back to reference Eder M, Raith S, Jalali J, Kovacs L (2013) Preoperative flap volume prediction in autologous abdominal breast reconstruction. Plast Reconstr Surg 131:437e–438ePubMedCrossRef Eder M, Raith S, Jalali J, Kovacs L (2013) Preoperative flap volume prediction in autologous abdominal breast reconstruction. Plast Reconstr Surg 131:437e–438ePubMedCrossRef
24.
go back to reference Allen RJ, Treece P (1994) Deep inferior epigastric perforator flap for breast reconstruction. Ann Plast Surg 32:32–38PubMedCrossRef Allen RJ, Treece P (1994) Deep inferior epigastric perforator flap for breast reconstruction. Ann Plast Surg 32:32–38PubMedCrossRef
25.
go back to reference Kovacs L, Yassouridis A, Zimmermann A et al (2006) Optimization of 3-dimensional imaging of the breast region with 3-dimensional laser scanners. Ann Plast Surg 56:229–236 Kovacs L, Yassouridis A, Zimmermann A et al (2006) Optimization of 3-dimensional imaging of the breast region with 3-dimensional laser scanners. Ann Plast Surg 56:229–236
26.
go back to reference Kuekrek H, Müller D, Paepke S, Dobritz M, Machens HG, Giunta RE (2011) Preoperative CT angiography for planning free perforator flaps in breast reconstruction. Handchir Mikrochir Plast Chir 43:88–94PubMedCrossRef Kuekrek H, Müller D, Paepke S, Dobritz M, Machens HG, Giunta RE (2011) Preoperative CT angiography for planning free perforator flaps in breast reconstruction. Handchir Mikrochir Plast Chir 43:88–94PubMedCrossRef
27.
go back to reference Eder M, Brockmann G, Zimmermann A et al (2012) Evaluation of precision and accuracy assessment of different 3-D surface imaging systems for biomedical purposes. J Digit Imaging 26:163–172PubMedCentralCrossRef Eder M, Brockmann G, Zimmermann A et al (2012) Evaluation of precision and accuracy assessment of different 3-D surface imaging systems for biomedical purposes. J Digit Imaging 26:163–172PubMedCentralCrossRef
28.
go back to reference Katch VL, Campaigne B, Freedson P et al (1980) Contribution of breast volume and weight to body fat distribution in females. Am J Phys Anthropol 53:93–100PubMedCrossRef Katch VL, Campaigne B, Freedson P et al (1980) Contribution of breast volume and weight to body fat distribution in females. Am J Phys Anthropol 53:93–100PubMedCrossRef
29.
go back to reference Martin AD, Daniel MZ, Drinkwater DT, Clarys JP (1994) Adipose tissue density, estimated adipose lipid fraction and whole body adiposity in male cadavers. Int J Obes Relat Metab Disord 18:79–83 Martin AD, Daniel MZ, Drinkwater DT, Clarys JP (1994) Adipose tissue density, estimated adipose lipid fraction and whole body adiposity in male cadavers. Int J Obes Relat Metab Disord 18:79–83
30.
go back to reference Newman TM, Vasile J, Levine JL et al (2010) Perforator flap magnetic resonance angiography for reconstructive breast surgery: a review of 25 deep inferior epigastric and gluteal perforator artery flap patients. J Magn Reson Imaging 31:1176–1184PubMedCrossRef Newman TM, Vasile J, Levine JL et al (2010) Perforator flap magnetic resonance angiography for reconstructive breast surgery: a review of 25 deep inferior epigastric and gluteal perforator artery flap patients. J Magn Reson Imaging 31:1176–1184PubMedCrossRef
31.
go back to reference Rozen WM, Ashton MW, Whitaker IS et al (2009) The financial implications of computed tomographic angiography in DIEP flap surgery: a cost analysis. Microsurgery 29:168–169PubMedCrossRef Rozen WM, Ashton MW, Whitaker IS et al (2009) The financial implications of computed tomographic angiography in DIEP flap surgery: a cost analysis. Microsurgery 29:168–169PubMedCrossRef
32.
go back to reference van der Pot WJ, Kreulen M, Melis P, Hage JJ (2010) Specific volume of female subcutaneous abdominal tissue as a reference in autologous breast reconstruction. J Reconstr Microsurg 26:185–188PubMedCrossRef van der Pot WJ, Kreulen M, Melis P, Hage JJ (2010) Specific volume of female subcutaneous abdominal tissue as a reference in autologous breast reconstruction. J Reconstr Microsurg 26:185–188PubMedCrossRef
33.
go back to reference Patel AJ, Kulkarni M, O’Broin ES (2009) A TRAM flap design refinement for use in delayed breast reconstruction. J Plast Reconstr Aesthet Surg 62:1135–1139PubMedCrossRef Patel AJ, Kulkarni M, O’Broin ES (2009) A TRAM flap design refinement for use in delayed breast reconstruction. J Plast Reconstr Aesthet Surg 62:1135–1139PubMedCrossRef
34.
go back to reference Tregaskiss A, Vermaak PV, Boulton R, Morris RJ (2012) The template technique for breast mound planning when using abdominal flaps for breast reconstruction. Breast 21:686–689PubMedCrossRef Tregaskiss A, Vermaak PV, Boulton R, Morris RJ (2012) The template technique for breast mound planning when using abdominal flaps for breast reconstruction. Breast 21:686–689PubMedCrossRef
35.
go back to reference Ahcan U, Bracun D, Zivec K, Pavlic R, Butala P (2012) The use of 3D laser imaging and a new breast replica cast as a method to optimize autologous breast reconstruction after mastectomy. Breast 21:183–189PubMedCrossRef Ahcan U, Bracun D, Zivec K, Pavlic R, Butala P (2012) The use of 3D laser imaging and a new breast replica cast as a method to optimize autologous breast reconstruction after mastectomy. Breast 21:183–189PubMedCrossRef
36.
go back to reference Jalali J, Eder M, Raith S, Volf A, von Waldenfels F, Kovacs L (2012) Breast reconstruction using patients own tissue based on CT angiography and 3-D surface scanning. In: Proceedings of the 3rd international conference and exhibition on 3D body scanning technologies. Lugano, Switzerland, pp 189–195 Jalali J, Eder M, Raith S, Volf A, von Waldenfels F, Kovacs L (2012) Breast reconstruction using patients own tissue based on CT angiography and 3-D surface scanning. In: Proceedings of the 3rd international conference and exhibition on 3D body scanning technologies. Lugano, Switzerland, pp 189–195
Metadata
Title
Three-dimensional prediction of free-flap volume in autologous breast reconstruction by CT angiography imaging
Authors
Maximilian Eder
Stefan Raith
Jalil Jalali
Daniel Müller
Yves Harder
Martin Dobritz
Nikolaos A. Papadopulos
Hans-Günther Machens
Laszlo Kovacs
Publication date
01-07-2014
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 4/2014
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-013-0941-4

Other articles of this Issue 4/2014

International Journal of Computer Assisted Radiology and Surgery 4/2014 Go to the issue