Skip to main content
Top
Published in: Forensic Toxicology 1/2018

01-01-2018 | Original Article

Reliable determination of cyanide, thiocyanate and azide in human whole blood by GC–MS, and its application in NAGINATA–GC–MS screening

Authors: Keiko Kudo, Yosuke Usumoto, Naomi Sameshima, Miki Okumura, Akiko Tsuji, Noriaki Ikeda

Published in: Forensic Toxicology | Issue 1/2018

Login to get access

Abstract

Purpose

Cyanide, its metabolite thiocyanate and azide in human biological fluids are commonly analyzed by gas chromatography–mass spectrometry (GC–MS) after derivatization with pentafluorobenzyl bromide using extractive alkylation. However, the reported methods have some drawbacks. We examined each step of these reported methods and attempted to establish a more reliable method to determine the levels of the above compounds in human whole blood. We also examined the applicability of the established method to NAGINATA–GC–MS screening.

Methods

The deproteinization method, internal standard (IS), the cause of column damage, and the effect of the addition of ascorbic acid were examined, and the best procedure was selected. The obtained data, including mass specta, retention times and calibration curves were registered to the database of NAGINATA software.

Results

The analysis of cyanide in whole blood was possible only when the blood was deproteinized with trichloroacetic acid. A high recovery of thiocyanate and azide was obtained without the deproteinization step. K13C15N (for cyanide) and tribromobenzene (for thiocyanate and azide) were selected as ISs. The column damage caused by the phase transfer catalyst was successfully eliminated by passing the catalyst containing solution through an ethyl benzoic sulfonic silica gel column. By these improvements, a more reliable determination method was established. All anions were rapidly identified using NAGINATA software, and the approximate concentration of each compound in whole blood was obtained at the same time.

Conclusions

Because NAGINATA–GC–MS screening can rapidly identify these poisons without using toxic compounds as reference standards, it should be useful in forensic and emergency medicine laboratories.
Literature
1.
go back to reference Le Garff E, Delannoy Y, Mesli V, Allorge D, Hédouin V, Tournel G (2016) Cyanide suicide after deep web shopping: a case report. Am J Forensic Med Pathol 37:194–197CrossRefPubMed Le Garff E, Delannoy Y, Mesli V, Allorge D, Hédouin V, Tournel G (2016) Cyanide suicide after deep web shopping: a case report. Am J Forensic Med Pathol 37:194–197CrossRefPubMed
2.
go back to reference Musshoff F, Schmidt P, Daldrup T, Madea B (2002) Cyanide fatalities: case studies of four suicide and one homicide. Am J Forensic Med Pathol 23:315–320CrossRefPubMed Musshoff F, Schmidt P, Daldrup T, Madea B (2002) Cyanide fatalities: case studies of four suicide and one homicide. Am J Forensic Med Pathol 23:315–320CrossRefPubMed
3.
4.
go back to reference Meatherall R, Oleschuk C (2015) Suicidal fatality from azide ingestion. J Forensic Sci 60:1666–1667CrossRefPubMed Meatherall R, Oleschuk C (2015) Suicidal fatality from azide ingestion. J Forensic Sci 60:1666–1667CrossRefPubMed
5.
go back to reference Schwarz ES, Wax PM, Kleinschmidt KC, Sharma K, Chung WM, Cantu G, Spargo E, Todd E (2014) Multiple poisoning with sodium azide at a local restaurant. J Emerg Med 46:491–494CrossRefPubMed Schwarz ES, Wax PM, Kleinschmidt KC, Sharma K, Chung WM, Cantu G, Spargo E, Todd E (2014) Multiple poisoning with sodium azide at a local restaurant. J Emerg Med 46:491–494CrossRefPubMed
6.
go back to reference Kikuchi M, Sato M, Ito T, Honda M (2001) Application of a new analytical method using gas chromatography and gas chromatography mass spectrometry for the azide ion to human blood and urine samples of actual case. J Chromatogr B 752:149–157CrossRef Kikuchi M, Sato M, Ito T, Honda M (2001) Application of a new analytical method using gas chromatography and gas chromatography mass spectrometry for the azide ion to human blood and urine samples of actual case. J Chromatogr B 752:149–157CrossRef
7.
go back to reference Kage S, Nagata T, Kudo K (1996) Determination of cyanide and thiocyante in blood by gas chromatography and gas chromatography–mass spectrometry. J Chromatogr B 675:27–32CrossRef Kage S, Nagata T, Kudo K (1996) Determination of cyanide and thiocyante in blood by gas chromatography and gas chromatography–mass spectrometry. J Chromatogr B 675:27–32CrossRef
8.
go back to reference Bhandari RK, Oda RP, Youso SL, Petrikovics I, Bebarta VS, Rockwood GA, Logue BA (2012) Simultaneous determination of cyanide and thiocyanate in plasma by chemical ionization gas chromatography mass-spectrometry (CI-GC–MS). Anal Bioanal Chem 404:2287–2294CrossRefPubMed Bhandari RK, Oda RP, Youso SL, Petrikovics I, Bebarta VS, Rockwood GA, Logue BA (2012) Simultaneous determination of cyanide and thiocyanate in plasma by chemical ionization gas chromatography mass-spectrometry (CI-GC–MS). Anal Bioanal Chem 404:2287–2294CrossRefPubMed
9.
go back to reference Paul BD, Smith ML (2006) Cyanide and thiocyanate in human saliva by gas chromatography–mass spectrometry. J Anal Toxicol 30:511–515CrossRefPubMed Paul BD, Smith ML (2006) Cyanide and thiocyanate in human saliva by gas chromatography–mass spectrometry. J Anal Toxicol 30:511–515CrossRefPubMed
10.
go back to reference Bhandari RK, Manandhar E, Oda RP, Rockwood GA, Logue BA (2014) Simultaneous high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS–MS) analysis of cyanide and thiocyanate from swine plasma. Anal Bioanal Chem 406:727–734CrossRefPubMed Bhandari RK, Manandhar E, Oda RP, Rockwood GA, Logue BA (2014) Simultaneous high-performance liquid chromatography–tandem mass spectrometry (HPLC–MS–MS) analysis of cyanide and thiocyanate from swine plasma. Anal Bioanal Chem 406:727–734CrossRefPubMed
11.
go back to reference Ohmori T, Ohsawa I, Komano A, Kishi S, Sato T, Seto Y (2014) High distribution of azide in blood investigated in vivo, and its stability in blood investigated in vitro. Forensic Toxicol 32:251–257CrossRef Ohmori T, Ohsawa I, Komano A, Kishi S, Sato T, Seto Y (2014) High distribution of azide in blood investigated in vivo, and its stability in blood investigated in vitro. Forensic Toxicol 32:251–257CrossRef
12.
go back to reference Kage S, Kudo K, Ikeda N (2000) Determination of azide in blood and urine by gas chromatography–mass spectrometry. J Anal Toxicol 24:429–432CrossRefPubMed Kage S, Kudo K, Ikeda N (2000) Determination of azide in blood and urine by gas chromatography–mass spectrometry. J Anal Toxicol 24:429–432CrossRefPubMed
13.
go back to reference Kudo K, Ishida T, Hikiji W, Hayashida M, Uekusa K, Usumoto Y, Tsuji A, Ikeda N (2009) Construction of calibration-locking databases for rapid and reliable drug screening by gas chromatography–mass spectrometry. Forensic Toxicol 27:21–31CrossRef Kudo K, Ishida T, Hikiji W, Hayashida M, Uekusa K, Usumoto Y, Tsuji A, Ikeda N (2009) Construction of calibration-locking databases for rapid and reliable drug screening by gas chromatography–mass spectrometry. Forensic Toxicol 27:21–31CrossRef
14.
go back to reference Kudo K, Usumoto Y, Usui K, Hayashida M, Kurisaki E, Saka K, Tsuji A, Ikeda N (2014) Rapid and simultaneous extraction of acidic and basic drugs from human whole blood for reliable semi-quantitative NAGINATA drug screening by GC–MS. Forensic Toxicol 32:97–104CrossRef Kudo K, Usumoto Y, Usui K, Hayashida M, Kurisaki E, Saka K, Tsuji A, Ikeda N (2014) Rapid and simultaneous extraction of acidic and basic drugs from human whole blood for reliable semi-quantitative NAGINATA drug screening by GC–MS. Forensic Toxicol 32:97–104CrossRef
15.
go back to reference Seto Y (1995) Oxidative conversion of thiocyanate to cyanide by oxyhemoglobin during acid denaturation. Arch Biochem Biophys 321:245–254CrossRefPubMed Seto Y (1995) Oxidative conversion of thiocyanate to cyanide by oxyhemoglobin during acid denaturation. Arch Biochem Biophys 321:245–254CrossRefPubMed
16.
go back to reference Desharnais B, Huppé G, Lamarche M, Mireault P, Skinner CD (2012) Cyanide quantification in post-mortem biological matrices by headspace GC–MS. Forensic Sci Int 222:346–351CrossRefPubMed Desharnais B, Huppé G, Lamarche M, Mireault P, Skinner CD (2012) Cyanide quantification in post-mortem biological matrices by headspace GC–MS. Forensic Sci Int 222:346–351CrossRefPubMed
17.
go back to reference McAllister JL, Roby RJ, Levine B, Purser D (2011) The effect of sodium fluoride on the stability of cyanide in postmortem blood samples from fire victims. Forensic Sci Int 209:29–33CrossRefPubMed McAllister JL, Roby RJ, Levine B, Purser D (2011) The effect of sodium fluoride on the stability of cyanide in postmortem blood samples from fire victims. Forensic Sci Int 209:29–33CrossRefPubMed
18.
go back to reference McAllister JL, Roby RJ, Levine B, Purser D (2008) Stability of cyanide in cadavers and in postmortem stored tissue specimens: a review. J Anal Toxicol 32:612–620CrossRefPubMed McAllister JL, Roby RJ, Levine B, Purser D (2008) Stability of cyanide in cadavers and in postmortem stored tissue specimens: a review. J Anal Toxicol 32:612–620CrossRefPubMed
19.
go back to reference Baselt RC (2017) Disposition of toxic drugs and chemicals in man, 11th edn. Biomedical Publications, Seal Beach Baselt RC (2017) Disposition of toxic drugs and chemicals in man, 11th edn. Biomedical Publications, Seal Beach
Metadata
Title
Reliable determination of cyanide, thiocyanate and azide in human whole blood by GC–MS, and its application in NAGINATA–GC–MS screening
Authors
Keiko Kudo
Yosuke Usumoto
Naomi Sameshima
Miki Okumura
Akiko Tsuji
Noriaki Ikeda
Publication date
01-01-2018
Publisher
Springer Japan
Published in
Forensic Toxicology / Issue 1/2018
Print ISSN: 1860-8965
Electronic ISSN: 1860-8973
DOI
https://doi.org/10.1007/s11419-017-0397-2

Other articles of this Issue 1/2018

Forensic Toxicology 1/2018 Go to the issue