Skip to main content
Top
Published in: Forensic Toxicology 2/2012

01-07-2012 | Original Article

A simple and reliable method for quantifying plasma concentrations of tetracyclic antidepressants using monolithic silica solid-phase extraction tips

Authors: Daigo Hayashi, Takeshi Kumazawa, Chika Hasegawa, Xiao-Pen Lee, Akemi Marumo, Seisaku Uchigasaki, Mitsuru Kawamura, Keizo Sato

Published in: Forensic Toxicology | Issue 2/2012

Login to get access

Abstract

Three tetracyclic antidepressants, mianserin, mirtazapine, and setiptiline, were extracted from human plasma samples using a new micropipette solid-phase extraction tip containing a monolithic silica gel packing material, the MonoTip C18. The plasma samples (0.1 ml), which contained mianserin, mirtazapine, and setiptiline, were mixed with 330 μl of distilled water and 50 μl of 0.5 M glycine–sodium hydroxide buffer solution (pH 8). After centrifugation, the supernatant was extracted onto the C18 phase of the tip (pipette tip volume, 200 μl) by 25 sequential aspirating/dispensing cycles. The three analytes retained in the C18 phase were eluted with methanol by 5 aspirating/dispensing cycles. The eluate was subjected to measurements by gas chromatography (GC) with nitrogen–phosphorus detection (NPD). The recoveries of the three antidepressants were 84.6–99.6% and the limits of detection for each drug were between 2.4 and 15 ng/ml of plasma. The maximum intraday and interday coefficients of variation for the drugs was below 10.6%. Regression equations for the three drugs showed excellent linearity in the range of 50–5000 ng/ml for mianserin and mirtazapine and 50–10 000 ng/ml for setiptiline. The antidepressants were stable for at least 12 h at 4°C, 4 weeks at −80°C, and through three freeze–thaw cycles in plasma. The validated method was successfully used to quantify the plasma concentrations of mirtazapine in a human subject after oral administration of the drug. Although we achieved analyte detection with GC-NPD, the present monolithic micropipette extraction method for tetracyclic antidepressants seems to be very useful for combining it with GC–mass spectrometry (MS) and/or liquid chromatography–tandem MS to secure high simplicity, purification, reproducibility, and sensitivity.
Literature
1.
go back to reference Pinder RM (1991) Mianserin: pharmacological and clinical correlates. Nord J Psychiatry 45:13–26CrossRef Pinder RM (1991) Mianserin: pharmacological and clinical correlates. Nord J Psychiatry 45:13–26CrossRef
3.
go back to reference Puzantian T (1998) Mirtazapine, an antidepressant. Am J Health Syst Pharm 55:44–49PubMed Puzantian T (1998) Mirtazapine, an antidepressant. Am J Health Syst Pharm 55:44–49PubMed
4.
go back to reference Anttila SAK, Leinone EVJ (2001) A review of pharmacological and clinical profile of mirtazapine. CNS Drug Rev 7:249–264PubMedCrossRef Anttila SAK, Leinone EVJ (2001) A review of pharmacological and clinical profile of mirtazapine. CNS Drug Rev 7:249–264PubMedCrossRef
5.
go back to reference Yamamura S, Abe M, Nakagawa M, Ochi S, Ueno S, Okada M (2011) Different actions for acute and chronic administration of mirtazapine on serotonergic transmission associated with raphe nuclei and their innervation cortical regions. Neuropharmacology 60:550–560PubMedCrossRef Yamamura S, Abe M, Nakagawa M, Ochi S, Ueno S, Okada M (2011) Different actions for acute and chronic administration of mirtazapine on serotonergic transmission associated with raphe nuclei and their innervation cortical regions. Neuropharmacology 60:550–560PubMedCrossRef
6.
go back to reference Koski A, Vuori E, Ojanpera I (2005) Newer antidepressants: evaluation of fatal toxicity index and interaction with alcohol based on Finnish postmortem data. Int J Leg Med 119:344–348CrossRef Koski A, Vuori E, Ojanpera I (2005) Newer antidepressants: evaluation of fatal toxicity index and interaction with alcohol based on Finnish postmortem data. Int J Leg Med 119:344–348CrossRef
7.
go back to reference Kirkton C, Mclntyre IM (2006) Therapeutic and toxic concentrations of mirtazapine. J Anal Toxicol 30:687–691PubMed Kirkton C, Mclntyre IM (2006) Therapeutic and toxic concentrations of mirtazapine. J Anal Toxicol 30:687–691PubMed
8.
go back to reference Kudo K, Ishida T, Hikiji W, Usumoto Y, Umehara T, Nagamatsu K, Tsuji A, Ikeda N (2010) Pattern of poisoning in Japan: selection of drugs and poisons for systematic toxicological analysis. Forensic Toxicol 28:25–32CrossRef Kudo K, Ishida T, Hikiji W, Usumoto Y, Umehara T, Nagamatsu K, Tsuji A, Ikeda N (2010) Pattern of poisoning in Japan: selection of drugs and poisons for systematic toxicological analysis. Forensic Toxicol 28:25–32CrossRef
9.
go back to reference Duverneuil C, de la Grandmaison GL, de Mazancourt P, Alvarez J-C (2003) A high-performance liquid chromatography method with photodiode-array UV detection for therapeutic drug monitoring of the nontricyclic antidepressant drugs. Ther Drug Monit 25:565–573PubMedCrossRef Duverneuil C, de la Grandmaison GL, de Mazancourt P, Alvarez J-C (2003) A high-performance liquid chromatography method with photodiode-array UV detection for therapeutic drug monitoring of the nontricyclic antidepressant drugs. Ther Drug Monit 25:565–573PubMedCrossRef
10.
go back to reference Titier K, Castaing N, Scotto-Gemez E, Pehourcq F, Moore N, Molimard M (2003) High-performance liquid chromatographic method with diode array detection for identification and quantification of the eight new antidepressants and five of their active metabolites in plasma after overdose. Ther Drug Monit 25:581–587PubMedCrossRef Titier K, Castaing N, Scotto-Gemez E, Pehourcq F, Moore N, Molimard M (2003) High-performance liquid chromatographic method with diode array detection for identification and quantification of the eight new antidepressants and five of their active metabolites in plasma after overdose. Ther Drug Monit 25:581–587PubMedCrossRef
11.
go back to reference Xu P, Li H-D, Chen B-M, Ma N, Yan M, Zhu Y-G (2008) Determination of mianserin in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI/MS): application to a bioequivalence study in Chinese volunteers. J Pharm Biomed Anal 47:994–999PubMedCrossRef Xu P, Li H-D, Chen B-M, Ma N, Yan M, Zhu Y-G (2008) Determination of mianserin in human plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-ESI/MS): application to a bioequivalence study in Chinese volunteers. J Pharm Biomed Anal 47:994–999PubMedCrossRef
12.
go back to reference Wille SMR, Maudens KE, Van Peteghem CH, Lambert WEE (2005) Development of a solid phase extraction for 13 ‘new’ generation antidepressants and their active metabolites for gas chromatographic–mass spectrometric analysis. J Chromatogr A 1098:19–29PubMedCrossRef Wille SMR, Maudens KE, Van Peteghem CH, Lambert WEE (2005) Development of a solid phase extraction for 13 ‘new’ generation antidepressants and their active metabolites for gas chromatographic–mass spectrometric analysis. J Chromatogr A 1098:19–29PubMedCrossRef
13.
go back to reference Shinozuka T, Terada M, Tanaka E (2006) Solid-phase extraction and analysis of 20 antidepressant drugs in human plasma by LC/MS with SSI method. Forensic Sci Int 162:108–112PubMedCrossRef Shinozuka T, Terada M, Tanaka E (2006) Solid-phase extraction and analysis of 20 antidepressant drugs in human plasma by LC/MS with SSI method. Forensic Sci Int 162:108–112PubMedCrossRef
14.
go back to reference Wille SMR, Van Hee P, Neels HM, Van Peteghem CH, Lambert WE (2007) Comparison of electron and chemical ionization modes by validation of a quantitative gas chromatographic-mass spectrometric assay of new generation antidepressants and their active metabolites in plasma. J Chromatogr A 1176:236–245PubMedCrossRef Wille SMR, Van Hee P, Neels HM, Van Peteghem CH, Lambert WE (2007) Comparison of electron and chemical ionization modes by validation of a quantitative gas chromatographic-mass spectrometric assay of new generation antidepressants and their active metabolites in plasma. J Chromatogr A 1176:236–245PubMedCrossRef
15.
go back to reference Marumo A, Kumazawa T, Lee X-P, Hasegawa C, Suzuki O, Sato K (2008) Utility of disk solid-phase extraction for whole blood samples: analysis of some tetracyclic antidepressants by gas chromatography with nitrogen-phosphorus detection. Forensic Toxicol 26:13–18CrossRef Marumo A, Kumazawa T, Lee X-P, Hasegawa C, Suzuki O, Sato K (2008) Utility of disk solid-phase extraction for whole blood samples: analysis of some tetracyclic antidepressants by gas chromatography with nitrogen-phosphorus detection. Forensic Toxicol 26:13–18CrossRef
16.
go back to reference Gonçalves Silva BJ, Costa Queiroz RH, Costa Queiroz ME (2007) Simultaneous determination of nontricyclic antidepressants in human plasma by solid-phase microextraction and liquid chromatography (SPME-LC). J Anal Toxicol 31:313–320PubMed Gonçalves Silva BJ, Costa Queiroz RH, Costa Queiroz ME (2007) Simultaneous determination of nontricyclic antidepressants in human plasma by solid-phase microextraction and liquid chromatography (SPME-LC). J Anal Toxicol 31:313–320PubMed
17.
go back to reference Miyazaki S, Morisato K, Ishizuka N, Minakuchi H, Shintani Y, Furuno M, Nakanishi K (2004) Development of a monolithic silica extraction tip for the analysis of proteins. J Chromatogr A 1043:19–25PubMedCrossRef Miyazaki S, Morisato K, Ishizuka N, Minakuchi H, Shintani Y, Furuno M, Nakanishi K (2004) Development of a monolithic silica extraction tip for the analysis of proteins. J Chromatogr A 1043:19–25PubMedCrossRef
18.
go back to reference Kumazawa T, Hasegawa C, Lee X-P, Sato K (2010) New and unique methods of solid-phase extraction for use before instrumental analysis of xenobiotics in human specimens. Forensic Toxicol 28:61–68CrossRef Kumazawa T, Hasegawa C, Lee X-P, Sato K (2010) New and unique methods of solid-phase extraction for use before instrumental analysis of xenobiotics in human specimens. Forensic Toxicol 28:61–68CrossRef
19.
go back to reference Hasegawa C, Kumazawa T, Lee X-P, Fujishiro M, Kuriki A, Marumo A, Seno H, Sato K (2006) Simultaneous determination of ten antihistamine drugs in human plasma using pipette tip solid-phase extraction and gas chromatography/mass spectrometry. Rapid Commun Mass Spectrom 20:537–543PubMedCrossRef Hasegawa C, Kumazawa T, Lee X-P, Fujishiro M, Kuriki A, Marumo A, Seno H, Sato K (2006) Simultaneous determination of ten antihistamine drugs in human plasma using pipette tip solid-phase extraction and gas chromatography/mass spectrometry. Rapid Commun Mass Spectrom 20:537–543PubMedCrossRef
20.
go back to reference Kumazawa T, Hasegawa C, Lee X-P, Marumo A, Shinmen N, Ishii A, Seno H, Sato K (2006) Pipette tip solid-phase extraction and gas chromatography–mass spectrometry for the determination of mequitazine in human plasma. Talanta 70:474–478PubMedCrossRef Kumazawa T, Hasegawa C, Lee X-P, Marumo A, Shinmen N, Ishii A, Seno H, Sato K (2006) Pipette tip solid-phase extraction and gas chromatography–mass spectrometry for the determination of mequitazine in human plasma. Talanta 70:474–478PubMedCrossRef
21.
go back to reference Hasegawa C, Kumazawa T, Lee X-P, Marumo A, Shinmen N, Seno H, Sato K (2007) Pipette tip solid-phase extraction and gas chromatography–mass spectrometry for the determination of methamphetamine and amphetamine in human whole blood. Anal Bioanal Chem 389:563–570PubMedCrossRef Hasegawa C, Kumazawa T, Lee X-P, Marumo A, Shinmen N, Seno H, Sato K (2007) Pipette tip solid-phase extraction and gas chromatography–mass spectrometry for the determination of methamphetamine and amphetamine in human whole blood. Anal Bioanal Chem 389:563–570PubMedCrossRef
22.
go back to reference Kumazawa T, Hasegawa C, Lee X-P, Hara K, Seno H, Suzuki O, Sato K (2007) Simultaneous determination of methamphetamine and amphetamine in human urine using pipette tip solid-phase extraction and gas chromatography–mass spectrometry. J Pharm Biomed Anal 44:602–607PubMedCrossRef Kumazawa T, Hasegawa C, Lee X-P, Hara K, Seno H, Suzuki O, Sato K (2007) Simultaneous determination of methamphetamine and amphetamine in human urine using pipette tip solid-phase extraction and gas chromatography–mass spectrometry. J Pharm Biomed Anal 44:602–607PubMedCrossRef
23.
go back to reference Lee X-P, Hasegawa C, Kumazawa T, Shinmen N, Shoji Y, Seno H, Sato K (2008) Determination of tricyclic antidepressants in human plasma using pipette tip solid-phase extraction and gas chromatography–mass spectrometry. J Sep Sci 31:2265–2271PubMedCrossRef Lee X-P, Hasegawa C, Kumazawa T, Shinmen N, Shoji Y, Seno H, Sato K (2008) Determination of tricyclic antidepressants in human plasma using pipette tip solid-phase extraction and gas chromatography–mass spectrometry. J Sep Sci 31:2265–2271PubMedCrossRef
24.
go back to reference Kumazawa T, Hasegawa C, Uchigasaki S, Lee X-P, Suzuki O, Sato K (2011) Quantitative determination of phenothiazine derivatives in human plasma using monolithic silica solid-phase extraction tips and gas chromatography–mass spectrometry. J Chromatogr A 1218:2521–2527PubMedCrossRef Kumazawa T, Hasegawa C, Uchigasaki S, Lee X-P, Suzuki O, Sato K (2011) Quantitative determination of phenothiazine derivatives in human plasma using monolithic silica solid-phase extraction tips and gas chromatography–mass spectrometry. J Chromatogr A 1218:2521–2527PubMedCrossRef
25.
go back to reference Hasegawa C, Kumazawa T, Uchigasaki S, Lee X-P, Sato K, Terada M, Kurosaki K (2011) Determination of dextromethorphan in human plasma using pipette tip solid-phase extraction and gas chromatography–mass spectrometry. Anal Bioanal Chem 401:2215–2223PubMedCrossRef Hasegawa C, Kumazawa T, Uchigasaki S, Lee X-P, Sato K, Terada M, Kurosaki K (2011) Determination of dextromethorphan in human plasma using pipette tip solid-phase extraction and gas chromatography–mass spectrometry. Anal Bioanal Chem 401:2215–2223PubMedCrossRef
27.
go back to reference van den Broek I, Sparidans RW, Huitema AD, Schellens JH, Beijnen JH (2006) Development and validation of a quantitative assay for the measurement of two HIV-fusion inhibitors, enfuvirtide and tifuvirtide, and one metabolite of enfuvirtide (M-20) in human plasma by liquid chromatography–tandem mass spectrometry. J Chromatogr B 837:49–58CrossRef van den Broek I, Sparidans RW, Huitema AD, Schellens JH, Beijnen JH (2006) Development and validation of a quantitative assay for the measurement of two HIV-fusion inhibitors, enfuvirtide and tifuvirtide, and one metabolite of enfuvirtide (M-20) in human plasma by liquid chromatography–tandem mass spectrometry. J Chromatogr B 837:49–58CrossRef
28.
go back to reference Viswanathan CT, Bansal S, Booth B, DeStefano AJ, Rose MJ, Sailstad J, Shah VP, Skelly JP, Swann PG, Weiner R (2007) Quantitative bioanalytical methods validation and implementation: best practices for chromatographic and ligand binding assays. Pharm Res 24:1962–1973PubMedCrossRef Viswanathan CT, Bansal S, Booth B, DeStefano AJ, Rose MJ, Sailstad J, Shah VP, Skelly JP, Swann PG, Weiner R (2007) Quantitative bioanalytical methods validation and implementation: best practices for chromatographic and ligand binding assays. Pharm Res 24:1962–1973PubMedCrossRef
29.
go back to reference Suzuki O, Kumazawa T, Seno H, Hattori H (1989) Rapid isolation with Sep-Pak C18 cartridges and wide-bore capillary gas chromatography of some barbiturates. Med Sci Law 29:242–248PubMed Suzuki O, Kumazawa T, Seno H, Hattori H (1989) Rapid isolation with Sep-Pak C18 cartridges and wide-bore capillary gas chromatography of some barbiturates. Med Sci Law 29:242–248PubMed
30.
go back to reference Huang Z, Zhang S (2003) Confirmation of amphetamine, methamphetamine, MDA and MDMA in urine samples using disk solid-phase extraction and gas chromatography–mass spectrometry after immunoassay screening. J Chromatogr B 792:241–247CrossRef Huang Z, Zhang S (2003) Confirmation of amphetamine, methamphetamine, MDA and MDMA in urine samples using disk solid-phase extraction and gas chromatography–mass spectrometry after immunoassay screening. J Chromatogr B 792:241–247CrossRef
31.
go back to reference Watts VW, Simonick TF (1986) Screening of basic drugs in biological samples using dual column capillary chromatography and nitrogen-phosphorus detectors. J Anal Toxicol 10:198–204PubMed Watts VW, Simonick TF (1986) Screening of basic drugs in biological samples using dual column capillary chromatography and nitrogen-phosphorus detectors. J Anal Toxicol 10:198–204PubMed
32.
go back to reference Sánchez de la Torre C, Martínez MA, Almarza E (2005) Determination of several psychiatric drugs in whole blood using capillary gas-liquid chromatography with nitrogen phosphorus detection: comparison of two solid phase extraction procedures. Forensic Sci Int 155:193–204PubMedCrossRef Sánchez de la Torre C, Martínez MA, Almarza E (2005) Determination of several psychiatric drugs in whole blood using capillary gas-liquid chromatography with nitrogen phosphorus detection: comparison of two solid phase extraction procedures. Forensic Sci Int 155:193–204PubMedCrossRef
33.
go back to reference Ishii A, Kurihara R, Kojima T, Sano T, Mizuno Y, Yamakawa Y, Katsumata Y (2000) Sensitive determination of mianserin and setiptiline in body fluids by gas chromatography with surface ionization detection (GC-SID). Leg Med 2:115–118CrossRef Ishii A, Kurihara R, Kojima T, Sano T, Mizuno Y, Yamakawa Y, Katsumata Y (2000) Sensitive determination of mianserin and setiptiline in body fluids by gas chromatography with surface ionization detection (GC-SID). Leg Med 2:115–118CrossRef
34.
go back to reference Schulz M, Schmoldt A (2003) Therapeutic and toxic blood concentrations of more than 800 drugs and other xenobiotics. Pharmazie 58:447–474PubMed Schulz M, Schmoldt A (2003) Therapeutic and toxic blood concentrations of more than 800 drugs and other xenobiotics. Pharmazie 58:447–474PubMed
35.
go back to reference Namera A, Watanabe T, Yashiki M, Iwasaki Y, Kojima T (1998) Simple analysis of tetracyclic antidepressants in blood using headspace-solid-phase microextraction and GC-MS. J Anal Toxicol 22:396–400PubMed Namera A, Watanabe T, Yashiki M, Iwasaki Y, Kojima T (1998) Simple analysis of tetracyclic antidepressants in blood using headspace-solid-phase microextraction and GC-MS. J Anal Toxicol 22:396–400PubMed
36.
go back to reference Frahnert C, Rao ML, Grasmäder K (2003) Analysis of eighteen antidepressants, four atypical antipsychotics and active metabolites in serum by liquid chromatography: a simple tool for therapeutic drug monitoring. J Chromatogr B 794:35–47CrossRef Frahnert C, Rao ML, Grasmäder K (2003) Analysis of eighteen antidepressants, four atypical antipsychotics and active metabolites in serum by liquid chromatography: a simple tool for therapeutic drug monitoring. J Chromatogr B 794:35–47CrossRef
Metadata
Title
A simple and reliable method for quantifying plasma concentrations of tetracyclic antidepressants using monolithic silica solid-phase extraction tips
Authors
Daigo Hayashi
Takeshi Kumazawa
Chika Hasegawa
Xiao-Pen Lee
Akemi Marumo
Seisaku Uchigasaki
Mitsuru Kawamura
Keizo Sato
Publication date
01-07-2012
Publisher
Springer Japan
Published in
Forensic Toxicology / Issue 2/2012
Print ISSN: 1860-8965
Electronic ISSN: 1860-8973
DOI
https://doi.org/10.1007/s11419-012-0132-y

Other articles of this Issue 2/2012

Forensic Toxicology 2/2012 Go to the issue