Skip to main content
Top
Published in: Molecular Imaging and Biology 4/2020

01-08-2020 | Magnetic Resonance Imaging | Research Article

Optimization of Keyhole Imaging Parameters for Glutamate Chemical Exchange Saturation Transfer MRI at 7.0 T

Authors: Dong-Hoon Lee, Do-Wan Lee, Chul-Woong Woo, Jae-Im Kwon, Jeong Kon Kim, Kyung Won Kim, Dong-Cheol Woo

Published in: Molecular Imaging and Biology | Issue 4/2020

Login to get access

Abstract

Purpose

To evaluate the effects of a reference image and keyhole factor (Kf) selections for high-frequency substitution on keyhole imaging technique for applications in glutamate chemical exchange saturation transfer (GluCEST) imaging.

Procedures

The CEST data were obtained using a 7.0 T MRI scanner. We used varied Kf ranges that constituted from 16.67 to 75 % of the full k-space. The reference image was respectively selected for − 3 and + 3 ppm images that associated with the GluCEST calculation and the unsaturated image. The zero-padding algorithm was applied for the missing k-space lines in the low-frequency data collected to compare the results obtained from using the keyhole imaging technique. All the techniques were evaluated using a healthy rat group and extended to the status epilepticus rat group to explore their applicability and usability.

Results

The calculated GluCEST signals and visually inspected results from the reconstructed GluCEST maps indicated that the combination of unsaturated image as a reference image, and over 50 % of Kf showed consistent signals and image quality compared with the fully sampled CEST data.

Conclusions

Combining the keyhole imaging technique with GluCEST imaging enables stable image reconstruction and quantitative evaluation, and this approach is potentially applicable in various CEST imaging applications.
Literature
1.
go back to reference Dula AN, Smith SA, Gore JC (2013) Application of chemical exchange saturation transfer (CEST) MRI for endogenous contrast at 7 tesla. J Neuroimaging 23:526–532CrossRef Dula AN, Smith SA, Gore JC (2013) Application of chemical exchange saturation transfer (CEST) MRI for endogenous contrast at 7 tesla. J Neuroimaging 23:526–532CrossRef
2.
go back to reference Jones KM, Pollard AC, Pagel MD (2018) Clinical applications of chemical exchange saturation transfer (CEST) MRI. J Magn Reson Imaging 47:11–27CrossRef Jones KM, Pollard AC, Pagel MD (2018) Clinical applications of chemical exchange saturation transfer (CEST) MRI. J Magn Reson Imaging 47:11–27CrossRef
3.
go back to reference van Zijl PCM, Yadav NN (2011) Chemical exchange saturation transfer (CEST): what is in a name and what isn’t? Magn Reson Med 65:927–948CrossRef van Zijl PCM, Yadav NN (2011) Chemical exchange saturation transfer (CEST): what is in a name and what isn’t? Magn Reson Med 65:927–948CrossRef
4.
go back to reference Zhou J, Blakeley JO, Hua J et al (2008) Practical data acquisition method for human brain tumor amide proton transfer (APT) imaging. Magn Reson Med 60:842–849 Zhou J, Blakeley JO, Hua J et al (2008) Practical data acquisition method for human brain tumor amide proton transfer (APT) imaging. Magn Reson Med 60:842–849
5.
go back to reference Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195CrossRef Lustig M, Donoho D, Pauly JM (2007) Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 58:1182–1195CrossRef
6.
7.
go back to reference Hu X, Parrish T (1994) Reduction of field of view for dynamic imaging. Magn Reson Med 31:691–694CrossRef Hu X, Parrish T (1994) Reduction of field of view for dynamic imaging. Magn Reson Med 31:691–694CrossRef
8.
go back to reference She H, Greer JS, Zhang S et al (2019) Accelerating chemical exchange saturation transfer MRI with parallel blind compressed sensing. Magn Reson Med 81:504–513 She H, Greer JS, Zhang S et al (2019) Accelerating chemical exchange saturation transfer MRI with parallel blind compressed sensing. Magn Reson Med 81:504–513
9.
go back to reference Jaspan ON, Fleysher R, Lipton ML (2015) Compressed sensing MRI: a review of the clinical literature. Br J Radiol 88:20150487CrossRef Jaspan ON, Fleysher R, Lipton ML (2015) Compressed sensing MRI: a review of the clinical literature. Br J Radiol 88:20150487CrossRef
10.
go back to reference Heo HY, Zhang Y, Lee DH, Jiang S, Zhao X, Zhou J (2017) Accelerating chemical exchange saturation transfer (CEST) MRI by combining compressed sensing and sensitivity encoding techniques. Magn Reson Med 77:779–786CrossRef Heo HY, Zhang Y, Lee DH, Jiang S, Zhao X, Zhou J (2017) Accelerating chemical exchange saturation transfer (CEST) MRI by combining compressed sensing and sensitivity encoding techniques. Magn Reson Med 77:779–786CrossRef
11.
go back to reference Varma G, Lenkinski RE, Vinogradov E (2012) Keyhole chemical exchange saturation transfer. Magn Reson Med 68:1228–1233CrossRef Varma G, Lenkinski RE, Vinogradov E (2012) Keyhole chemical exchange saturation transfer. Magn Reson Med 68:1228–1233CrossRef
12.
go back to reference Cai KJ, Haris M, Singh A et al (2012) Magnetic resonance imaging of glutamate. Nat Med 18:302–306 Cai KJ, Haris M, Singh A et al (2012) Magnetic resonance imaging of glutamate. Nat Med 18:302–306
13.
go back to reference Singh A, Cai KJ, Haris M, Hariharan H, Reddy R (2013) On B1 inhomogeneity correction of in vivo human brain glutamate chemical exchange saturation transfer contrast at 7T. Magn Reson Med 69:818–824CrossRef Singh A, Cai KJ, Haris M, Hariharan H, Reddy R (2013) On B1 inhomogeneity correction of in vivo human brain glutamate chemical exchange saturation transfer contrast at 7T. Magn Reson Med 69:818–824CrossRef
14.
go back to reference Du YP, Parker DL, Davis WL, Cao G (1994) Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography. J Magn Reson Imaging 4:733–741CrossRef Du YP, Parker DL, Davis WL, Cao G (1994) Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography. J Magn Reson Imaging 4:733–741CrossRef
15.
go back to reference Lee DH, Lee DW, Kwon JI et al (2019) In vivo mapping and quantification of creatine using chemical exchange saturation transfer imaging in rat models of epileptic seizure. Mol Imaging Biol 21:232–239 Lee DH, Lee DW, Kwon JI et al (2019) In vivo mapping and quantification of creatine using chemical exchange saturation transfer imaging in rat models of epileptic seizure. Mol Imaging Biol 21:232–239
16.
17.
go back to reference Park J, Zhang Q, Jellus V, Simonetti O, Li D (2005) Artifact and noise suppression in GRAPPA imaging using improved k-space coil calibration and variable density sampling. Magn Reson Med 53:186–193CrossRef Park J, Zhang Q, Jellus V, Simonetti O, Li D (2005) Artifact and noise suppression in GRAPPA imaging using improved k-space coil calibration and variable density sampling. Magn Reson Med 53:186–193CrossRef
18.
go back to reference Xiao Z, Hoge WS, Mulkern RV, Zhao L, Hu G, Kyriakos WE (2008) Comparison of parallel MRI reconstruction methods for accelerated 3D fast spin-echo imaging. Magn Reson Med 60:650–660CrossRef Xiao Z, Hoge WS, Mulkern RV, Zhao L, Hu G, Kyriakos WE (2008) Comparison of parallel MRI reconstruction methods for accelerated 3D fast spin-echo imaging. Magn Reson Med 60:650–660CrossRef
19.
go back to reference Mogatadakala KV, Bankson JA, Narayana PA (2008) Three-element phased-array coil for imaging of rat spinal cord at 7T. Magn Reson Med 60:1498–1505CrossRef Mogatadakala KV, Bankson JA, Narayana PA (2008) Three-element phased-array coil for imaging of rat spinal cord at 7T. Magn Reson Med 60:1498–1505CrossRef
20.
go back to reference Herrmann KH, Schmidt S, Kretz A et al (2012) Possibilities and limitations for high resolution small animal MRI on a clinical whole-body 3T scanner. Magn Reson Mater Phy 25:233–244 Herrmann KH, Schmidt S, Kretz A et al (2012) Possibilities and limitations for high resolution small animal MRI on a clinical whole-body 3T scanner. Magn Reson Mater Phy 25:233–244
21.
go back to reference Lee DH, Lee DW, Kwon JI et al (2019) Retrospective brain motion correction in glutamate chemical exchange saturation transfer (GluCEST) MRI. Mol Imaging Biol 21:1064–1070 Lee DH, Lee DW, Kwon JI et al (2019) Retrospective brain motion correction in glutamate chemical exchange saturation transfer (GluCEST) MRI. Mol Imaging Biol 21:1064–1070
23.
go back to reference Jones CK, Polders D, Hua J et al (2012) In vivo three-dimensional whole-brain pulsed steady-state chemical exchange saturation transfer at 7 T. Magn Reson Med 67:1579–1589 Jones CK, Polders D, Hua J et al (2012) In vivo three-dimensional whole-brain pulsed steady-state chemical exchange saturation transfer at 7 T. Magn Reson Med 67:1579–1589
24.
go back to reference Zaiss M, Xu JZ, Goerke S et al (2014) Inverse Z-spectrum analysis for spillover-, MT-, and T-1-corrected steady-state pulsed CEST-MRI - application to pHweighted MRI of acute stroke. NMR Biomed 27:240–252 Zaiss M, Xu JZ, Goerke S et al (2014) Inverse Z-spectrum analysis for spillover-, MT-, and T-1-corrected steady-state pulsed CEST-MRI - application to pHweighted MRI of acute stroke. NMR Biomed 27:240–252
Metadata
Title
Optimization of Keyhole Imaging Parameters for Glutamate Chemical Exchange Saturation Transfer MRI at 7.0 T
Authors
Dong-Hoon Lee
Do-Wan Lee
Chul-Woong Woo
Jae-Im Kwon
Jeong Kon Kim
Kyung Won Kim
Dong-Cheol Woo
Publication date
01-08-2020
Publisher
Springer International Publishing
Published in
Molecular Imaging and Biology / Issue 4/2020
Print ISSN: 1536-1632
Electronic ISSN: 1860-2002
DOI
https://doi.org/10.1007/s11307-019-01461-z

Other articles of this Issue 4/2020

Molecular Imaging and Biology 4/2020 Go to the issue