Skip to main content
Top
Published in: Oral Radiology 3/2019

01-09-2019 | Original Article

Protection evaluation of non-lead radiation-shielding fabric: preliminary exposure-dose study

Authors: Ju Hee Kang, Song Hee Oh, Jung-Il Oh, Seong-Hun Kim, Yong-Suk Choi, Eui-Hwan Hwang

Published in: Oral Radiology | Issue 3/2019

Login to get access

Abstract

Objectives

The aim of this study was to evaluate the effectiveness and shielding performance of a novel recently developed non-lead radiation-shielding fabric containing bismuth oxide (BO-fabric).

Methods

BO-fabric was fabricated using urethane resin and bismuth nanopowder. A dose-measurement method was employed to evaluate the radiation-attenuation characteristics of the shielding fabric in accordance with the Korean Standards standard. The shielding performances (%) were calculated by measuring the radiation doses after lamination with increasing layers of fabric (1–10 layers). The physical performance of the fabric in terms of flexural and abrasion resistances was evaluated by the Korea Apparel Testing and Research Institute (KATRI).

Results

The radiation-attenuation capabilities of one layer of BO-fabric were 58.5, 49.9, and 43.0% at tube voltages of 60, 80, and 100 kVp, respectively. The radiation-shielding performance upon lamination of BO-fabric gradually increased as the number of layers increased. Excellent flexural and abrasion resistances were observed in the KATRI evaluation.

Conclusions

A non-lead radiation-shielding fabric based on urethane resin and bismuth was fabricated and examined, revealing an excellent shielding performance. Owing to the flexibility and simple operation of the fabric, it can be employed for various designs of clothing and protective apparel with many purposes.
Literature
1.
go back to reference Radiation UNSCEAR. Report of the United Nations Scientific Committee on the Effects of Atomic Radiation. Fifty-sixth Session (10–18 July 2008). New York: United Nations Publications; 2008. Radiation UNSCEAR. Report of the United Nations Scientific Committee on the Effects of Atomic Radiation. Fifty-sixth Session (10–18 July 2008). New York: United Nations Publications; 2008.
2.
go back to reference Lee YK. Level of radiation dose in university hospital noninsured private health screening programs in Korea. Environ Health Toxicol. 2016;31:e2016007.CrossRefPubMedCentralPubMed Lee YK. Level of radiation dose in university hospital noninsured private health screening programs in Korea. Environ Health Toxicol. 2016;31:e2016007.CrossRefPubMedCentralPubMed
3.
go back to reference McCaffrey JP, Tessier F, Shen H. Radiation shielding materials and radiation scatter effects for interventional radiology (IR) physicians. Med Phys. 2012;39:4537–46.CrossRefPubMed McCaffrey JP, Tessier F, Shen H. Radiation shielding materials and radiation scatter effects for interventional radiology (IR) physicians. Med Phys. 2012;39:4537–46.CrossRefPubMed
4.
go back to reference Schlattl H, Zankl M, Eder H, Hoeschen C. Shielding properties of lead-free protective clothing and their impact on radiation doses. Med Phys. 2007;34:4270–80.CrossRefPubMed Schlattl H, Zankl M, Eder H, Hoeschen C. Shielding properties of lead-free protective clothing and their impact on radiation doses. Med Phys. 2007;34:4270–80.CrossRefPubMed
5.
go back to reference Min KS, Chang HS, Bae JM, Park SH, Hong CU, Kim EC. The induction of heme oxygenase-1 modulates bismuth oxide-induced cytotoxicity in human dental pulp cells. J Endod. 2007;33:1342–6.CrossRefPubMed Min KS, Chang HS, Bae JM, Park SH, Hong CU, Kim EC. The induction of heme oxygenase-1 modulates bismuth oxide-induced cytotoxicity in human dental pulp cells. J Endod. 2007;33:1342–6.CrossRefPubMed
6.
go back to reference Anderson AM, Blazek JM, Garg P, Payne BJ, Mohan RS. Bismuth (III) oxide perchlorate promoted rearrangement of epoxides to aldehydes and ketones. Tetrahedron Lett. 2000;41:1527–30.CrossRef Anderson AM, Blazek JM, Garg P, Payne BJ, Mohan RS. Bismuth (III) oxide perchlorate promoted rearrangement of epoxides to aldehydes and ketones. Tetrahedron Lett. 2000;41:1527–30.CrossRef
7.
go back to reference Kaewkhao J, Limsuwan P. Mass attenuation coefficients and effective atomic numbers in phosphate glass containing Bi2O3, PbO and BaO at 662 keV. Nucl Instrum Methods Phys Res A. 2010;619:295–7.CrossRef Kaewkhao J, Limsuwan P. Mass attenuation coefficients and effective atomic numbers in phosphate glass containing Bi2O3, PbO and BaO at 662 keV. Nucl Instrum Methods Phys Res A. 2010;619:295–7.CrossRef
8.
go back to reference Zuguchi M, Chida K, Taura M, Inaba Y, Ebata A, Yamada S. Usefulness of non-lead aprons in radiation protection for physicians performing interventional procedures. Radiat Prot Dosimetry. 2008;131:531–4.CrossRefPubMed Zuguchi M, Chida K, Taura M, Inaba Y, Ebata A, Yamada S. Usefulness of non-lead aprons in radiation protection for physicians performing interventional procedures. Radiat Prot Dosimetry. 2008;131:531–4.CrossRefPubMed
9.
go back to reference Uthoff H, Peña C, West J, Contreras F, Benenati JF, Katzen BT. Evaluation of novel disposable, light-weight radiation protection devices in an interventional radiology setting: a randomized controlled trial. AJR Am J Roentgenol. 2013;200:915–20.CrossRefPubMed Uthoff H, Peña C, West J, Contreras F, Benenati JF, Katzen BT. Evaluation of novel disposable, light-weight radiation protection devices in an interventional radiology setting: a randomized controlled trial. AJR Am J Roentgenol. 2013;200:915–20.CrossRefPubMed
10.
go back to reference Scuderi GJ, Brusovanik GV, Campbell DR, Henry RP, Kwon B, Vaccaro AR. Evaluation of non-lead-based protective radiological material in spinal surgery. Spine J. 2006;6:577–82.CrossRefPubMed Scuderi GJ, Brusovanik GV, Campbell DR, Henry RP, Kwon B, Vaccaro AR. Evaluation of non-lead-based protective radiological material in spinal surgery. Spine J. 2006;6:577–82.CrossRefPubMed
11.
go back to reference Kim CG. The development of bismuth shielding to protect the thyroid gland in radiations environment. Indian J Sci Technol. 2016;9. Kim CG. The development of bismuth shielding to protect the thyroid gland in radiations environment. Indian J Sci Technol. 2016;9.
12.
go back to reference Mendes M, Costa F, Figueira C, Madeira P, Teles P, Vaz P. Assessment of patient dose reduction by bismuth shielding in CT using measurements, GEANT4 and MCNPX simulations. Radiat Prot Dosimetry. 2015;165:175–81.CrossRefPubMed Mendes M, Costa F, Figueira C, Madeira P, Teles P, Vaz P. Assessment of patient dose reduction by bismuth shielding in CT using measurements, GEANT4 and MCNPX simulations. Radiat Prot Dosimetry. 2015;165:175–81.CrossRefPubMed
13.
go back to reference Ashayer S, Askari M, Afarideh H. Optimal per cent by weight of elements in diagnostic quality radiation shielding materials. Radiat Prot Dosimetry. 2012;149:268–88.CrossRefPubMed Ashayer S, Askari M, Afarideh H. Optimal per cent by weight of elements in diagnostic quality radiation shielding materials. Radiat Prot Dosimetry. 2012;149:268–88.CrossRefPubMed
14.
go back to reference Chang KH, Lee W, Choo DM, Lee CS, Kim Y. Dose reduction in CT using bismuth shielding: measurements and Monte Carlo simulations. Radiat Prot Dosimetry. 2010;138:382–8.CrossRefPubMed Chang KH, Lee W, Choo DM, Lee CS, Kim Y. Dose reduction in CT using bismuth shielding: measurements and Monte Carlo simulations. Radiat Prot Dosimetry. 2010;138:382–8.CrossRefPubMed
15.
go back to reference McCaffrey JP, Shen H, Downton B, Mainegra-Hing E. Radiation attenuation by lead and nonlead materials used in radiation shielding garments. Med Phys. 2007;34:530–7.CrossRef McCaffrey JP, Shen H, Downton B, Mainegra-Hing E. Radiation attenuation by lead and nonlead materials used in radiation shielding garments. Med Phys. 2007;34:530–7.CrossRef
Metadata
Title
Protection evaluation of non-lead radiation-shielding fabric: preliminary exposure-dose study
Authors
Ju Hee Kang
Song Hee Oh
Jung-Il Oh
Seong-Hun Kim
Yong-Suk Choi
Eui-Hwan Hwang
Publication date
01-09-2019
Publisher
Springer Singapore
Published in
Oral Radiology / Issue 3/2019
Print ISSN: 0911-6028
Electronic ISSN: 1613-9674
DOI
https://doi.org/10.1007/s11282-018-0338-8

Other articles of this Issue 3/2019