Skip to main content
Top
Published in: Journal of Medical Systems 10/2015

01-10-2015 | Systems-Level Quality Improvement

Determination of Fatigue Following Maximal Loaded Treadmill Exercise by Using Wavelet Packet Transform Analysis and MLPNN from MMG-EMG Data Combinations

Authors: Gürkan Bilgin, İ. Ethem Hindistan, Y. Gül Özkaya, Etem Köklükaya, Övünç Polat, Ömer H. Çolak

Published in: Journal of Medical Systems | Issue 10/2015

Login to get access

Abstract

The muscle fatigue can be expressed as decrease in maximal voluntary force generating capacity of the neuromuscular system as a result of peripheral changes at the level of the muscle, and also failure of the central nervous system to drive the motoneurons adequately. In this study, a muscle fatigue detection method based on frequency spectrum of electromyogram (EMG) and mechanomyogram (MMG) has been presented. The EMG and MMG data were obtained from 31 healthy, recreationally active men at the onset, and following exercise. All participants were performed a maximally exercise session in a motor-driven treadmill by using standard Bruce protocol which is the most widely used test to predict functional capacity. The method used in the present study consists of pre-processing, determination of the energy value based on wavelet packet transform, and classification phases. The results of the study demonstrated that changes in the MMG 176–234 Hz and EMG 254–313 Hz bands are critical to determine for muscle fatigue occurred following maximally exercise session. In conclusion, our study revealed that an algorithm with EMG and MMG combination based on frequency spectrum is more effective for the detection of muscle fatigue than EMG or MMG alone.
Literature
1.
go back to reference Comi, G., Leocani, L., Rossi, P., and Colombo, B., Physiopathology and treatment of fatigue in multiple sclerosis. J. Neurol. 248:174–179, 2001.CrossRefPubMed Comi, G., Leocani, L., Rossi, P., and Colombo, B., Physiopathology and treatment of fatigue in multiple sclerosis. J. Neurol. 248:174–179, 2001.CrossRefPubMed
2.
go back to reference Latash, M. L., Yee, M. J., Orpett, C., Slingo, A., and Nicholas, J. J., Combining electrical muscle stimulation with voluntary contraction for studying muscle fatique. Arch. Phys. Med. Rehabil. 75:29–35, 1994.PubMed Latash, M. L., Yee, M. J., Orpett, C., Slingo, A., and Nicholas, J. J., Combining electrical muscle stimulation with voluntary contraction for studying muscle fatique. Arch. Phys. Med. Rehabil. 75:29–35, 1994.PubMed
3.
4.
go back to reference Chaudhuri, A., Behan, P. O.; “Fatigue in neurological disorders”. Lancet., 2004, 978–988. Chaudhuri, A., Behan, P. O.; “Fatigue in neurological disorders”. Lancet., 2004, 978–988.
5.
go back to reference Mathur, S., Eng, J. J., and MacIntyre, D. L., Reliability of surface EMG during sustained contractions of the quadriceps. J. Electromyogr. Kinesiol. 15:102–110, 2005.CrossRefPubMed Mathur, S., Eng, J. J., and MacIntyre, D. L., Reliability of surface EMG during sustained contractions of the quadriceps. J. Electromyogr. Kinesiol. 15:102–110, 2005.CrossRefPubMed
6.
go back to reference Strimpakos, N., Georgios, G., Eleni, K., Vasilios, K., and Jacqueline, O., Issues in relation to the repeatability of and correlation between EMG and Borg scale assessments of neck muscle fatigue. J. Electromyogr. Kinesiol. 15(5):452–465, 2005.CrossRefPubMed Strimpakos, N., Georgios, G., Eleni, K., Vasilios, K., and Jacqueline, O., Issues in relation to the repeatability of and correlation between EMG and Borg scale assessments of neck muscle fatigue. J. Electromyogr. Kinesiol. 15(5):452–465, 2005.CrossRefPubMed
7.
go back to reference Ravier, P., Buttelli, O., Jennane, R., and Couratier, P., An EMG fractal indicator having different sensitivities to changes in force and muscle fatigue during voluntary static muscle contractions. J. Electromyogr. Kinesiol. 15:210–221, 2005.CrossRefPubMed Ravier, P., Buttelli, O., Jennane, R., and Couratier, P., An EMG fractal indicator having different sensitivities to changes in force and muscle fatigue during voluntary static muscle contractions. J. Electromyogr. Kinesiol. 15:210–221, 2005.CrossRefPubMed
8.
go back to reference De Luca, C. J., The use of surface electromyography in Biomech. J. Appl. Biomech. 13:135–163, 1997. De Luca, C. J., The use of surface electromyography in Biomech. J. Appl. Biomech. 13:135–163, 1997.
9.
go back to reference Lindstrom, L., Kadefors, R., and Petersen, I., An electromyographic index for localized muscle fatigue. J. Appl. Physiol. 43:750–754, 1977.PubMed Lindstrom, L., Kadefors, R., and Petersen, I., An electromyographic index for localized muscle fatigue. J. Appl. Physiol. 43:750–754, 1977.PubMed
10.
go back to reference Marras, W., Industrial electromyography (EMG). Int. J. Ind. Ergon. 6:89–74, 1990.CrossRef Marras, W., Industrial electromyography (EMG). Int. J. Ind. Ergon. 6:89–74, 1990.CrossRef
11.
12.
go back to reference Petrofsky, J. S., Glaser, R. M., Phillips, C. A., Lind, A. R., and Williams, C., Evaluation of amplitude and frequency components of the surface EMG as an index of muscle fatigue. Ergonomics 25:213–223, 1982.CrossRefPubMed Petrofsky, J. S., Glaser, R. M., Phillips, C. A., Lind, A. R., and Williams, C., Evaluation of amplitude and frequency components of the surface EMG as an index of muscle fatigue. Ergonomics 25:213–223, 1982.CrossRefPubMed
13.
go back to reference Güler, N. F., and Koçer, S., Classification of EMG signals using PCA and FFT. J. Med. Syst. 29(3):241–250, 2005.CrossRefPubMed Güler, N. F., and Koçer, S., Classification of EMG signals using PCA and FFT. J. Med. Syst. 29(3):241–250, 2005.CrossRefPubMed
14.
go back to reference Sakurai, T., Toda, M., Sakurazawa, S., Akita, J., Kondo, K., Nakamura, Y. “Detection of muscle fatigue by the surface electromyogram and its application”. 9th IEEE/ACIS international conference on computer and information science, 2010. Sakurai, T., Toda, M., Sakurazawa, S., Akita, J., Kondo, K., Nakamura, Y. “Detection of muscle fatigue by the surface electromyogram and its application”. 9th IEEE/ACIS international conference on computer and information science, 2010.
15.
go back to reference Soo, Y., Sugi, M., Nishino, M., Yokoi, H., Arai, T., Kato, R., Nakamura, T., Ota, J. “Quantative estimation of muscle fatigue using surface electromyography during static muscle contraction”. 31st annual international conference of the IEEE EMBS, 2009. Soo, Y., Sugi, M., Nishino, M., Yokoi, H., Arai, T., Kato, R., Nakamura, T., Ota, J. “Quantative estimation of muscle fatigue using surface electromyography during static muscle contraction”. 31st annual international conference of the IEEE EMBS, 2009.
16.
go back to reference Oka, H. “Estimation of muscle fatigue by using EMG and muscle stiffness”. 18th annual international conference of the IEEE engineering in medicine and biology society, Amsterdam 1996. Oka, H. “Estimation of muscle fatigue by using EMG and muscle stiffness”. 18th annual international conference of the IEEE engineering in medicine and biology society, Amsterdam 1996.
17.
go back to reference Jubeau, M., Zory, R., Gondin, J., Martin, A., and Maffiuletti, N. A., Effect of electrostimulation training-detraining on neuromuscular fatigue mechanisms. Neurosci. Lett. 424(1):41–46, 2007.CrossRefPubMed Jubeau, M., Zory, R., Gondin, J., Martin, A., and Maffiuletti, N. A., Effect of electrostimulation training-detraining on neuromuscular fatigue mechanisms. Neurosci. Lett. 424(1):41–46, 2007.CrossRefPubMed
18.
go back to reference Oliver, J., Armstrong, N., and Williams, C., Changes in jump performance and muscle activity following soccer-specific exercise”. J. Sports Sci. 13:1–8, 2007. Oliver, J., Armstrong, N., and Williams, C., Changes in jump performance and muscle activity following soccer-specific exercise”. J. Sports Sci. 13:1–8, 2007.
19.
go back to reference Al-Mulla, M. R., and Sepulveda, F., Super wavelet for sEMG signal extraction during dynamic fatiguing contractions. J. Med. Syst. 39(1):1–9, 2015.CrossRef Al-Mulla, M. R., and Sepulveda, F., Super wavelet for sEMG signal extraction during dynamic fatiguing contractions. J. Med. Syst. 39(1):1–9, 2015.CrossRef
20.
go back to reference Subasi, A., and Kiymik, M. K., Muscle fatigue detection in EMG using time–frequency methods, ICA and neural networks. J. Med. Syst. 34(4):777–785, 2010.CrossRefPubMed Subasi, A., and Kiymik, M. K., Muscle fatigue detection in EMG using time–frequency methods, ICA and neural networks. J. Med. Syst. 34(4):777–785, 2010.CrossRefPubMed
21.
go back to reference Orizio, C., Gobbo, M., Diemont, B., Esposito, F., and Veicsteinas, A., The surface mechanomyogram as a tool to describe the influence of fatigue on biceps brachii motor unit activation strategy. historical basis and novel evidence. Eur. J. Appl. Physiol. 90(3–4):326–36, 2003.CrossRefPubMed Orizio, C., Gobbo, M., Diemont, B., Esposito, F., and Veicsteinas, A., The surface mechanomyogram as a tool to describe the influence of fatigue on biceps brachii motor unit activation strategy. historical basis and novel evidence. Eur. J. Appl. Physiol. 90(3–4):326–36, 2003.CrossRefPubMed
22.
go back to reference Yang, Z.F., Kumar, D. K., Arjunan, S.P. “Mechanomyogram for identifying muscle activity and fatigue”. 31st annual international conference of the IEEE EMBS Minneapolis, Minnesota, USA, September 2–6, 2009. Yang, Z.F., Kumar, D. K., Arjunan, S.P. “Mechanomyogram for identifying muscle activity and fatigue”. 31st annual international conference of the IEEE EMBS Minneapolis, Minnesota, USA, September 2–6, 2009.
23.
go back to reference Shinohara, M., Kouzaki, M., Yoshihisa, T., and Fukunaga, T., Mechanomyography of the human quadriceps muscle during incremental cycle ergometry. Eur. J. Appl. Physiol. Occup. Physiol. 76:314–319, 1997.CrossRefPubMed Shinohara, M., Kouzaki, M., Yoshihisa, T., and Fukunaga, T., Mechanomyography of the human quadriceps muscle during incremental cycle ergometry. Eur. J. Appl. Physiol. Occup. Physiol. 76:314–319, 1997.CrossRefPubMed
24.
go back to reference Madeleine, P., Jørgensen, L. V., Søgaard, K., Arendt-Nielsen, L., and Sjøgaard, G., Development of muscle fatigue as assessed by electromyography and mechanomyography during continuous and intermittent low-force contractions: effects of the feedback mode. Eur. J. Appl. Physiol. 87:28–37, 2002.CrossRefPubMed Madeleine, P., Jørgensen, L. V., Søgaard, K., Arendt-Nielsen, L., and Sjøgaard, G., Development of muscle fatigue as assessed by electromyography and mechanomyography during continuous and intermittent low-force contractions: effects of the feedback mode. Eur. J. Appl. Physiol. 87:28–37, 2002.CrossRefPubMed
25.
go back to reference Kimura, T., Fujibayashi, M., Tanaka, S., and Moritani, T., Mechanomyographic responses in quadriceps muscles during fatigue by continuous cycle exercise. Eur. J. Appl. Physiol. 104:651–656, 2008.CrossRefPubMed Kimura, T., Fujibayashi, M., Tanaka, S., and Moritani, T., Mechanomyographic responses in quadriceps muscles during fatigue by continuous cycle exercise. Eur. J. Appl. Physiol. 104:651–656, 2008.CrossRefPubMed
26.
go back to reference Itoh, Y., Akataki, K., Mita, K., Watakabe, M., and Itoh, K., Time-frequency analysis of mechanomyogram during sustained contractions with muscle fatigue. Syst. Comput. Jpn. 35:26–36, 2004.CrossRef Itoh, Y., Akataki, K., Mita, K., Watakabe, M., and Itoh, K., Time-frequency analysis of mechanomyogram during sustained contractions with muscle fatigue. Syst. Comput. Jpn. 35:26–36, 2004.CrossRef
27.
go back to reference Orizio, C., Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies. Crit. Rev. Biomed. Eng. 21:201–243, 1993.PubMed Orizio, C., Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies. Crit. Rev. Biomed. Eng. 21:201–243, 1993.PubMed
28.
go back to reference Perry-Rana, S. R., Housh, T. J., Johnson, G. O., Bull, A. J., Berning, J. M., and Cramer, J. T., MMG and EMG responses during fatiguing isokinetic muscle contractions at different velocities. Muscle Nerve 26:367–373, 2002.CrossRefPubMed Perry-Rana, S. R., Housh, T. J., Johnson, G. O., Bull, A. J., Berning, J. M., and Cramer, J. T., MMG and EMG responses during fatiguing isokinetic muscle contractions at different velocities. Muscle Nerve 26:367–373, 2002.CrossRefPubMed
29.
go back to reference Beck, T. W., Housh, T. J., Johnson, G. O., Weir, J. P., Cramer, J. T., Coburn, J. W., and Malek, M. H., Mechanomyographic and electromyographic amplitude and frequency responses during fatiguing isokinetic muscle actions of the biceps brachii. Electromyograph. Clin. Neurophysiol. 44:431–441, 2004. Beck, T. W., Housh, T. J., Johnson, G. O., Weir, J. P., Cramer, J. T., Coburn, J. W., and Malek, M. H., Mechanomyographic and electromyographic amplitude and frequency responses during fatiguing isokinetic muscle actions of the biceps brachii. Electromyograph. Clin. Neurophysiol. 44:431–441, 2004.
30.
go back to reference Faller, L., Neto, G. N. N., Button, V. L. S. N., and Nohama, P., Muscle fatigue assessment by mechanomyography during application of NMES protocol. Rev. Brasil. Fisioterapia/Braz. J. Phys. Ther. 13:422–429, 2009.CrossRef Faller, L., Neto, G. N. N., Button, V. L. S. N., and Nohama, P., Muscle fatigue assessment by mechanomyography during application of NMES protocol. Rev. Brasil. Fisioterapia/Braz. J. Phys. Ther. 13:422–429, 2009.CrossRef
31.
go back to reference Beck, W. T., Tscharner, V. V., Housh, J. T., Cramer, T. J., Weir, P. J., Malek, H. M., and Mielke, M., Time/frequency events of surface mechanomyographic signals resolved by nonlinearly scaled wavelets. Biomed. Sign. Process. Contrl. 3:255–266, 2008.CrossRef Beck, W. T., Tscharner, V. V., Housh, J. T., Cramer, T. J., Weir, P. J., Malek, H. M., and Mielke, M., Time/frequency events of surface mechanomyographic signals resolved by nonlinearly scaled wavelets. Biomed. Sign. Process. Contrl. 3:255–266, 2008.CrossRef
32.
go back to reference Misiti, M., Misiti, Y., Oppenheim, G., Poggi, J. M., Wavelet Toolbox for use with MATLAB, User’s Guide, The Mathworks Inc., 1997–2002. Misiti, M., Misiti, Y., Oppenheim, G., Poggi, J. M., Wavelet Toolbox for use with MATLAB, User’s Guide, The Mathworks Inc., 1997–2002.
33.
go back to reference Bilgin, S., Çolak, O. H., Köklükaya, E., and Arı, N., Efficient solution for frequency band decomposition problem using wavelet packet in HRV. Digit. Sign. Process. 18(6):892–899, 2008.CrossRef Bilgin, S., Çolak, O. H., Köklükaya, E., and Arı, N., Efficient solution for frequency band decomposition problem using wavelet packet in HRV. Digit. Sign. Process. 18(6):892–899, 2008.CrossRef
34.
go back to reference Bilgin, S., Çolak, Ö. H., Polat, O., and Köklükaya, E., “Determination of a new VLF BAND in HRV for ventricular tachyarrhytmia patients”. J. Med. Syst. 34(2):155–160, 2010.CrossRefPubMed Bilgin, S., Çolak, Ö. H., Polat, O., and Köklükaya, E., “Determination of a new VLF BAND in HRV for ventricular tachyarrhytmia patients”. J. Med. Syst. 34(2):155–160, 2010.CrossRefPubMed
35.
go back to reference Beck, T. W., Housh, T. J., Johnson, G. O., Weir, J. P., Cramer, J. T., Coburn, J. W., and Malek, M. H., Comparison of Fourier and wavelet transform procedures for examining the mechanomyographic and electromyographic frequency domain responses during fatiguing isokinetic muscle actions of the biceps brachii. J. Electromyogr. Kinesiol. 15(2):190–199, 2005.CrossRefPubMed Beck, T. W., Housh, T. J., Johnson, G. O., Weir, J. P., Cramer, J. T., Coburn, J. W., and Malek, M. H., Comparison of Fourier and wavelet transform procedures for examining the mechanomyographic and electromyographic frequency domain responses during fatiguing isokinetic muscle actions of the biceps brachii. J. Electromyogr. Kinesiol. 15(2):190–199, 2005.CrossRefPubMed
36.
go back to reference Ebersole, K. T., O’Connor, K. M., and Wier, A. P., Mechanomyographic and electromyographic responses to repeated concentric muscle actions of the quadriceps femoris. J. Electromyogr. Kinesiol. 16(2):149–57, 2006.CrossRefPubMed Ebersole, K. T., O’Connor, K. M., and Wier, A. P., Mechanomyographic and electromyographic responses to repeated concentric muscle actions of the quadriceps femoris. J. Electromyogr. Kinesiol. 16(2):149–57, 2006.CrossRefPubMed
37.
go back to reference Ryan, E. D., Cramer, J. T., Egan, A. D., Hartman, M. J., and Herda, T. J., Time and frequency domain responses of the mechanomyogram and electromyogram during isometric ramp contractions: a comparison of the short-time Fourier and continuous wavelet transforms. J. Electromyogr. Kinesiol. 18(1):54–67, 2008.CrossRefPubMed Ryan, E. D., Cramer, J. T., Egan, A. D., Hartman, M. J., and Herda, T. J., Time and frequency domain responses of the mechanomyogram and electromyogram during isometric ramp contractions: a comparison of the short-time Fourier and continuous wavelet transforms. J. Electromyogr. Kinesiol. 18(1):54–67, 2008.CrossRefPubMed
38.
go back to reference Abbiss, C. R., and Laursen, P. B., Models to explain fatigue during prolonged endurance cycling. Sports Med. 35(10):865–898, 2005.CrossRefPubMed Abbiss, C. R., and Laursen, P. B., Models to explain fatigue during prolonged endurance cycling. Sports Med. 35(10):865–898, 2005.CrossRefPubMed
39.
go back to reference Pringle, J. S., and Jones, A. M., Maximal lactate steady state, critical power and EMG during cycling. Eur. J. Appl. Physiol. 88(3):214–226, 2002.CrossRefPubMed Pringle, J. S., and Jones, A. M., Maximal lactate steady state, critical power and EMG during cycling. Eur. J. Appl. Physiol. 88(3):214–226, 2002.CrossRefPubMed
40.
go back to reference Bruce, R. A., Methods of exercise testing: step test, bicycle, treadmill, isometrics. Am. J. Cardiol. 33(6):715–720, 1974.CrossRefPubMed Bruce, R. A., Methods of exercise testing: step test, bicycle, treadmill, isometrics. Am. J. Cardiol. 33(6):715–720, 1974.CrossRefPubMed
Metadata
Title
Determination of Fatigue Following Maximal Loaded Treadmill Exercise by Using Wavelet Packet Transform Analysis and MLPNN from MMG-EMG Data Combinations
Authors
Gürkan Bilgin
İ. Ethem Hindistan
Y. Gül Özkaya
Etem Köklükaya
Övünç Polat
Ömer H. Çolak
Publication date
01-10-2015
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 10/2015
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-015-0304-5

Other articles of this Issue 10/2015

Journal of Medical Systems 10/2015 Go to the issue