Skip to main content
Top
Published in: Journal of Medical Systems 5/2011

01-10-2011 | ORIGINAL PAPER

Standardization on Body Area Network and a Prototype System Based on UWB

Authors: Huan-Bang Li, Ryuji Kohno

Published in: Journal of Medical Systems | Issue 5/2011

Login to get access

Abstract

Body area network (BAN) is a promising wireless technology that realizes wireless connectivity among vital signal sensors deployed on human body. Monitoring various vital signals collected through BAN provides an efficient way to lower disease occurrence rate and reduce medical expenditure. Task Group 6 (TG6) within the IEEE 802 Local and Metropolitan Area Network Standards Committee is developing a BAN standard, i.e., IEEE 802.15.6. In which, specifications of three physical layers (PHYs) and a single common medium access control (MAC) are being drafted. The standardization process has been continuing for several years in the Task Group 6 (TG6) under Working Group 15 (WG). In this paper, we describe the up-to-date status of IEEE 802.15.6 standardization. Some main specifications under drafting are presented. Moreover, as an effort of implementing a BAN model, a prototype BAN system based on the high band of ultra-wideband (UWB) is demonstrated.
Literature
3.
go back to reference Astrin, A. W., Li, H.-B., and Kohno, R., “Standardization for Body Area Networks”. IEICE Trans. Commun. E92-B(2): 366–372, Feb. 2009.CrossRef Astrin, A. W., Li, H.-B., and Kohno, R., “Standardization for Body Area Networks”. IEICE Trans. Commun. E92-B(2): 366–372, Feb. 2009.CrossRef
4.
go back to reference Heile, R. F., “69th Session of meetings of the IEEE 802.15 Working Group for Wireless Personal Area Networks,” 15-10-0856-00-0000-nov2010-plenary-opening-report, Nov. 2010. Heile, R. F., “69th Session of meetings of the IEEE 802.15 Working Group for Wireless Personal Area Networks,” 15-10-0856-00-0000-nov2010-plenary-opening-report, Nov. 2010.
5.
go back to reference Li, H.-B., Schwoerer, J., Yoon, Y.-M., Farserotu, J., Yang, W.-B., Sayrafian, K., Miniutti, D., Lewis, D., and Gowans, A., “IEEE 802.15.6 Regulation Subcommittee Report,” 15-08-0034-10-0006, Sep. 2008. Li, H.-B., Schwoerer, J., Yoon, Y.-M., Farserotu, J., Yang, W.-B., Sayrafian, K., Miniutti, D., Lewis, D., and Gowans, A., “IEEE 802.15.6 Regulation Subcommittee Report,” 15-08-0034-10-0006, Sep. 2008.
6.
go back to reference Lewis, D., “802.15.6 Call for Applications - Response Summary,” 15-08-0407-05-0006, Nov. 2008. Lewis, D., “802.15.6 Call for Applications - Response Summary,” 15-08-0407-05-0006, Nov. 2008.
7.
go back to reference Yazdandoost, K.-Y., and Sayrafian, K., “Channel Model for Body Area Network (BAN)” 15-08-0780-01-0006, Nov. 2008. Yazdandoost, K.-Y., and Sayrafian, K., “Channel Model for Body Area Network (BAN)” 15-08-0780-01-0006, Nov. 2008.
8.
go back to reference Zhen, B., Patel, M., Lee, S.-H., Won, E.-T., and Astrin, A. W., “TG6 Technical Requirement Document (TRD),” 15-08-0644-09-0006, Nov. 2008. Zhen, B., Patel, M., Lee, S.-H., Won, E.-T., and Astrin, A. W., “TG6 Technical Requirement Document (TRD),” 15-08-0644-09-0006, Nov. 2008.
9.
go back to reference Li, H.-B., and Kohno, R., “Introduction of SG-BAN in IEEE 802.15 with related discussion”, Advances in Mobile and Wireless Communications. 16(IV): 223–238, Springer, 2008. Li, H.-B., and Kohno, R., “Introduction of SG-BAN in IEEE 802.15 with related discussion”, Advances in Mobile and Wireless Communications. 16(IV): 223–238, Springer, 2008.
10.
go back to reference Li, H.-B., Zhen, B., Hara, S., Ikegami, T., Takada, J.-I., and Kohno, R., “Prospective directions for TG6 by considering different dimension parameters”, 15-08-0528-01-0006, July 2008. Li, H.-B., Zhen, B., Hara, S., Ikegami, T., Takada, J.-I., and Kohno, R., “Prospective directions for TG6 by considering different dimension parameters”, 15-08-0528-01-0006, July 2008.
11.
go back to reference Astrin, A. W., “IEEE 802.15 TG6 Body Area Network – Closing report”, 15-10-0087-00-0006, Sep. 2010. Astrin, A. W., “IEEE 802.15 TG6 Body Area Network – Closing report”, 15-10-0087-00-0006, Sep. 2010.
13.
go back to reference ETSI TR 102 655 V1.1.1, “Electromagnetic compatibility and Radio spectrum Matters (ERM); System reference document; Short Range Devices (SRD); Low Power Active Medical Implants (LP-AMI) operating in a 20 MHz band within 2 360 MHz to 3 400 MHz,” November 2008 ETSI TR 102 655 V1.1.1, “Electromagnetic compatibility and Radio spectrum Matters (ERM); System reference document; Short Range Devices (SRD); Low Power Active Medical Implants (LP-AMI) operating in a 20 MHz band within 2 360 MHz to 3 400 MHz,” November 2008
14.
go back to reference FIPS Pub 197, Advanced Encryption Standard (AES), Nov. 2001. FIPS Pub 197, Advanced Encryption Standard (AES), Nov. 2001.
Metadata
Title
Standardization on Body Area Network and a Prototype System Based on UWB
Authors
Huan-Bang Li
Ryuji Kohno
Publication date
01-10-2011
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 5/2011
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-011-9662-9

Other articles of this Issue 5/2011

Journal of Medical Systems 5/2011 Go to the issue