Skip to main content
Top
Published in: Journal of Medical Systems 3/2012

01-06-2012 | ORIGINAL PAPER

Singular Value Decomposition Based Feature Extraction Technique for Physiological Signal Analysis

Authors: Cheng-Ding Chang, Chien-Chih Wang, Bernard C. Jiang

Published in: Journal of Medical Systems | Issue 3/2012

Login to get access

Abstract

Multiscale entropy (MSE) is one of the popular techniques to calculate and describe the complexity of the physiological signal. Many studies use this approach to detect changes in the physiological conditions in the human body. However, MSE results are easily affected by noise and trends, leading to incorrect estimation of MSE values. In this paper, singular value decomposition (SVD) is adopted to replace MSE to extract the features of physiological signals, and adopt the support vector machine (SVM) to classify the different physiological states. A test data set based on the PhysioNet website was used, and the classification results showed that using SVD to extract features of the physiological signal could attain a classification accuracy rate of 89.157%, which is higher than that using the MSE value (71.084%). The results show the proposed analysis procedure is effective and appropriate for distinguishing different physiological states. This promising result could be used as a reference for doctors in diagnosis of congestive heart failure (CHF) disease.
Literature
1.
go back to reference Costa, M., Goldberger, A. L., Peng, C. K., Multiscale entropy analysis of complex physiologic time series. Phys. Rev. Let. 89(6):068102(1–4), 2002. Costa, M., Goldberger, A. L., Peng, C. K., Multiscale entropy analysis of complex physiologic time series. Phys. Rev. Let. 89(6):068102(1–4), 2002.
2.
go back to reference Ferrario, M., Signorini, M. G., Magenes, G., and Cerutti, S., Comparison of entropy-based regularity estimators: Application to the fetal heart rate signal for the identification of fetal distress. IEEE Trans Biomed Eng 53(1):119–125, 2006.CrossRef Ferrario, M., Signorini, M. G., Magenes, G., and Cerutti, S., Comparison of entropy-based regularity estimators: Application to the fetal heart rate signal for the identification of fetal distress. IEEE Trans Biomed Eng 53(1):119–125, 2006.CrossRef
3.
go back to reference Patrick, R. N., Anderson, S. M., Jenkins, J. M., Williams, A. E., and Morris, J. A., Jr., Heart rate multiscale entropy at three hours predicts hospital mortality in 3,154 trauma patient. Shock 30(1):17–22, 2008.CrossRef Patrick, R. N., Anderson, S. M., Jenkins, J. M., Williams, A. E., and Morris, J. A., Jr., Heart rate multiscale entropy at three hours predicts hospital mortality in 3,154 trauma patient. Shock 30(1):17–22, 2008.CrossRef
4.
go back to reference Hung, C. H., and Jiang, B. C., Multi-scale entropy approach to physiological fatigue during long-term web browsing. Hum Factors Ergon Manuf 19(5):478–493, 2009.CrossRef Hung, C. H., and Jiang, B. C., Multi-scale entropy approach to physiological fatigue during long-term web browsing. Hum Factors Ergon Manuf 19(5):478–493, 2009.CrossRef
5.
go back to reference Trunkvalterova, Z., Javorka, M., Tonhajzerova, I., Javorkova, J., Lazarova, Z., Javorka, K., and Baumert, M., Reduced short-term complexity of heart rate and blood pressure dynamic in patients with diabetes mellitus type 1: Multiscale entropy analysis. Physiol Meas 29:817–828, 2008.CrossRef Trunkvalterova, Z., Javorka, M., Tonhajzerova, I., Javorkova, J., Lazarova, Z., Javorka, K., and Baumert, M., Reduced short-term complexity of heart rate and blood pressure dynamic in patients with diabetes mellitus type 1: Multiscale entropy analysis. Physiol Meas 29:817–828, 2008.CrossRef
6.
go back to reference Park, J. H., Kim, S., Kim, C. H., Cichocki, A., and Kim, K., Multiscale entropy analysis of EEG from patients under different pathological conditions. Fractals 15(4):399–404, 2007.CrossRef Park, J. H., Kim, S., Kim, C. H., Cichocki, A., and Kim, K., Multiscale entropy analysis of EEG from patients under different pathological conditions. Fractals 15(4):399–404, 2007.CrossRef
7.
go back to reference Costa, M., Peng, C. K., Goldberger, A. L., and Hausdorff, J. M., Multiscale entropy analysis of human gait dynamics. Physica. A, Statistical mechanics and its applications 330(1–2):53–60, 2003.MATHCrossRef Costa, M., Peng, C. K., Goldberger, A. L., and Hausdorff, J. M., Multiscale entropy analysis of human gait dynamics. Physica. A, Statistical mechanics and its applications 330(1–2):53–60, 2003.MATHCrossRef
8.
go back to reference Valencia, J. F., Porta, A., Vallverdú, M., Clarià, F., Baranowski, R., Orłowska-Baranowska, E., and Caminal, P., Refined multiscale entropy: Application to 24-h holter recordings of heart period variability in healthy and aortic stenosis subjects. IEEE Trans Biomed Eng 45(9):2202–2213, 2009.CrossRef Valencia, J. F., Porta, A., Vallverdú, M., Clarià, F., Baranowski, R., Orłowska-Baranowska, E., and Caminal, P., Refined multiscale entropy: Application to 24-h holter recordings of heart period variability in healthy and aortic stenosis subjects. IEEE Trans Biomed Eng 45(9):2202–2213, 2009.CrossRef
9.
go back to reference McNames J., Thong T., Aboy M. Impulse rejection filter for artifact removal in spectral analysis of biomedical signals. Proceedings of the 26th Annual International Conference of the IEEE EMBS, 145–148, September 1–5 2004 McNames J., Thong T., Aboy M. Impulse rejection filter for artifact removal in spectral analysis of biomedical signals. Proceedings of the 26th Annual International Conference of the IEEE EMBS, 145–148, September 1–5 2004
10.
go back to reference Kanjilal, P. P., Palit, S., and Saha, G., Fetal ECG extraction from single-channel maternal ECG using singular value decomposition. IEEE Trans Biomed Eng 44(1):51–59, 1997.CrossRef Kanjilal, P. P., Palit, S., and Saha, G., Fetal ECG extraction from single-channel maternal ECG using singular value decomposition. IEEE Trans Biomed Eng 44(1):51–59, 1997.CrossRef
11.
go back to reference Ayat, M., Assaleh, K., and Nashash, H., Fetal ECG extraction from a single abdominal ECG signal using SVD and polynomial classifiers. IEEE Workshop on Machine Learning for Signal Processing, Cancun, Mexico, 2008. Ayat, M., Assaleh, K., and Nashash, H., Fetal ECG extraction from a single abdominal ECG signal using SVD and polynomial classifiers. IEEE Workshop on Machine Learning for Signal Processing, Cancun, Mexico, 2008.
12.
go back to reference Moor, B. D., The singular value decomposition and long and short spaces of noisy matrices. IEEE Trans Signal Process 41(9):2826–2838, 1993.MATHCrossRef Moor, B. D., The singular value decomposition and long and short spaces of noisy matrices. IEEE Trans Signal Process 41(9):2826–2838, 1993.MATHCrossRef
15.
go back to reference Huang, N. E., Wu, M. C., Long, S. R., Shen, S. S. P., Qu, W., Gloersen, P., and Fan, K. L., A confidence limit for the empirical mode decomposition and hilbert spectrum analysis. Proc R Soc Lond A 459:2317–2345, 2003.MathSciNetMATHCrossRef Huang, N. E., Wu, M. C., Long, S. R., Shen, S. S. P., Qu, W., Gloersen, P., and Fan, K. L., A confidence limit for the empirical mode decomposition and hilbert spectrum analysis. Proc R Soc Lond A 459:2317–2345, 2003.MathSciNetMATHCrossRef
Metadata
Title
Singular Value Decomposition Based Feature Extraction Technique for Physiological Signal Analysis
Authors
Cheng-Ding Chang
Chien-Chih Wang
Bernard C. Jiang
Publication date
01-06-2012
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 3/2012
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-010-9636-3

Other articles of this Issue 3/2012

Journal of Medical Systems 3/2012 Go to the issue