Skip to main content
Top
Published in: Journal of Medical Systems 5/2011

01-10-2011 | Original Paper

Development of a Telecare System Based on ZigBee Mesh Network for Monitoring Blood Pressure of Patients with Hemodialysis in Health Care Centers

Authors: Yi-Chun Du, You-Yun Lee, Yun-Yuan Lu, Chia-Hung Lin, Ming-Jei Wu, Chung-Lin Chen, Tainsong Chen

Published in: Journal of Medical Systems | Issue 5/2011

Login to get access

Abstract

In Taiwan, the number of the patients needing dialysis increases rapidly in recent years. Because there is risk in every hemodialysis session, monitoring physiological status, such as blood pressure measurement every 30 min to 1 h is needed during about 4 h hemodialysis process. Therefore, an assisted measurement on blood pressure is needful in dialysis care centers. Telecare system (TCS) is regarded as one of important technique in the medical care. In this study, we utilized ZigBee wireless technique to establish a mesh network for monitoring blood pressure automatically and data storage in medical record system for display and further analysis. Moreover, while the blood pressure exceeds the normal range, the system could send a warning signal to remind, or inform the relatives and clinicians in health care center through the personal handy-phone system (PHS) immediately. The proposed system provides an assisted device for monitoring patients’ blood pressure during hemodialysis process and saving medical manpower.
Literature
1.
go back to reference Yoon, Y., Cho, J. H., and Yoon, G., Non-constrained blood pressure monitoring using ECG and PPG for personal healthcare. J. Med. Syst. 33(4):261–266, 2009.CrossRef Yoon, Y., Cho, J. H., and Yoon, G., Non-constrained blood pressure monitoring using ECG and PPG for personal healthcare. J. Med. Syst. 33(4):261–266, 2009.CrossRef
2.
go back to reference Jindal, K., Chan, C. T., Deziel, C., Hirsch, D., Soroka, S. D., Tonelli, M., and Culleton, B. F., Chapter 2: Management of blood pressure in hemodialysis patients. J. Am. Soc. Nephrol. 17:S8–S10, 2006. Jindal, K., Chan, C. T., Deziel, C., Hirsch, D., Soroka, S. D., Tonelli, M., and Culleton, B. F., Chapter 2: Management of blood pressure in hemodialysis patients. J. Am. Soc. Nephrol. 17:S8–S10, 2006.
3.
go back to reference Agarwal, R., Nissenson, A. R., Batlle, D., Coyne, D. W., Trout, J. R., and Warnock, D. G., Prevalence, treatment, and control of hypertension in chronic hemodialysis patients in the United States. Am. J. Med. 15:291–297, 2003.CrossRef Agarwal, R., Nissenson, A. R., Batlle, D., Coyne, D. W., Trout, J. R., and Warnock, D. G., Prevalence, treatment, and control of hypertension in chronic hemodialysis patients in the United States. Am. J. Med. 15:291–297, 2003.CrossRef
4.
go back to reference Hatcher, M., and Heetebry, I., Information technology in the future of health care. J. Med. Syst. 28(6):673–688, 2004.CrossRef Hatcher, M., and Heetebry, I., Information technology in the future of health care. J. Med. Syst. 28(6):673–688, 2004.CrossRef
5.
go back to reference Guler, N. F., and Ubeyli, E. D., Theory and applications of telemedicine. J. Med. Syst. 26(3):199–220, 2002.CrossRef Guler, N. F., and Ubeyli, E. D., Theory and applications of telemedicine. J. Med. Syst. 26(3):199–220, 2002.CrossRef
6.
go back to reference Gund, A., Ekman, I., Lindecrantz, K., et al., Design evaluation of a home-based telecare system for chronic heart failure patients. Conf. Proc. IEEE Eng. Med. Biol. Soc. 5851–5854, 2008. Gund, A., Ekman, I., Lindecrantz, K., et al., Design evaluation of a home-based telecare system for chronic heart failure patients. Conf. Proc. IEEE Eng. Med. Biol. Soc. 5851–5854, 2008.
7.
go back to reference Redmond, S. J., Lovell, N. H., Basilakis, J., and Celler, B. G., ECG quality measures in telecare monitoring. EMBS 2008. 30th Annual International Conference of the IEEE, 2869–2872, 2008. Redmond, S. J., Lovell, N. H., Basilakis, J., and Celler, B. G., ECG quality measures in telecare monitoring. EMBS 2008. 30th Annual International Conference of the IEEE, 2869–2872, 2008.
8.
go back to reference Chou, C. C., Chang, P. L., Lee, K. H., and Lee, T. T., Technology connecting people: Applying telecare in elderly health care. J. Nurs. 56(6):76–80, 2009. Chou, C. C., Chang, P. L., Lee, K. H., and Lee, T. T., Technology connecting people: Applying telecare in elderly health care. J. Nurs. 56(6):76–80, 2009.
9.
go back to reference Botsis, T., Demiris, G., Pedersen, S., and Hartvigsen, G., Home telecare technologies for the elderly. J. Telemed. Telecare 14(7):333–337, 2008.CrossRef Botsis, T., Demiris, G., Pedersen, S., and Hartvigsen, G., Home telecare technologies for the elderly. J. Telemed. Telecare 14(7):333–337, 2008.CrossRef
10.
go back to reference Yuen, H. K., and Pope, C., Oral home telecare for adults with tetraplegia: a feasibility study. Spec. Care Dent. 29(5):204–209, 2009.CrossRef Yuen, H. K., and Pope, C., Oral home telecare for adults with tetraplegia: a feasibility study. Spec. Care Dent. 29(5):204–209, 2009.CrossRef
11.
go back to reference Baisa, N., Designing wireless interfaces for patient monitoring equipment. RF Design Magazine, 1–5, 2005. Baisa, N., Designing wireless interfaces for patient monitoring equipment. RF Design Magazine, 1–5, 2005.
12.
go back to reference Lee, H. J., Lee, S. H., Kyoo-Seob, Ha, Jang, H. C., Chung, W., Kim, J. Y., Chang, Y., and Yoo, D. H., Ubiquitous healthcare service using ZigBee and mobile phone for elderly patients. Int. J. Med. Inform. 78(3):193–198, 2009.CrossRef Lee, H. J., Lee, S. H., Kyoo-Seob, Ha, Jang, H. C., Chung, W., Kim, J. Y., Chang, Y., and Yoo, D. H., Ubiquitous healthcare service using ZigBee and mobile phone for elderly patients. Int. J. Med. Inform. 78(3):193–198, 2009.CrossRef
13.
go back to reference Sahandi, R., Noroozi, S., Roushan, G., Heaslip, V., and Liu, Y., Wireless technology in the evolution of patient monitoring on general hospital wards. J. Med. Eng. Technol. 34(1):51–63, 2009.CrossRef Sahandi, R., Noroozi, S., Roushan, G., Heaslip, V., and Liu, Y., Wireless technology in the evolution of patient monitoring on general hospital wards. J. Med. Eng. Technol. 34(1):51–63, 2009.CrossRef
14.
go back to reference Shnayder, V., Chen, B., Lorincz, K., Jones, T. R. F. F., and Welsh, M., Sensor networks for medical care. Division for Engineering and Applied Sciences, 314, 2005. Shnayder, V., Chen, B., Lorincz, K., Jones, T. R. F. F., and Welsh, M., Sensor networks for medical care. Division for Engineering and Applied Sciences, 314, 2005.
15.
go back to reference Liu, Y., and Sahandi, R., ZigBee network for remote patient monitoring, 22nd International Symposium on Information, Communication and Automation Technologies, 29–31, 2009. Liu, Y., and Sahandi, R., ZigBee network for remote patient monitoring, 22nd International Symposium on Information, Communication and Automation Technologies, 29–31, 2009.
16.
go back to reference IEEE Std 802.15.4 Wireless Wireless Medium Access Control (MAC) and Physical Layer (PHY) Specifications for Low-Rate Wireless Personal Area Networks (LR-WPANs), May 2003. IEEE Std 802.15.4 Wireless Wireless Medium Access Control (MAC) and Physical Layer (PHY) Specifications for Low-Rate Wireless Personal Area Networks (LR-WPANs), May 2003.
17.
go back to reference Ding, G., Sahinoglu, Z., Orlik, P., Zhang, J., and Bhargava, B., Tree-based data broadcast in IEEE 802.15.4 and ZigBee networks. IEEE Trans. Mobile Comput. 38(11):1561–1574, 2006.CrossRef Ding, G., Sahinoglu, Z., Orlik, P., Zhang, J., and Bhargava, B., Tree-based data broadcast in IEEE 802.15.4 and ZigBee networks. IEEE Trans. Mobile Comput. 38(11):1561–1574, 2006.CrossRef
18.
go back to reference Kim, T., Kim, D., Park, N., Yoo, S., and Lopez, T. S, Shortcut tree routing in ZigBee networks. Proceeding of the Wireless Pervasive Computing,ISWPC ’07. 2nd International Symposium, San Juan, 42–47, 2007. Kim, T., Kim, D., Park, N., Yoo, S., and Lopez, T. S, Shortcut tree routing in ZigBee networks. Proceeding of the Wireless Pervasive Computing,ISWPC ’07. 2nd International Symposium, San Juan, 42–47, 2007.
19.
go back to reference Ondrej, S., Zdenek, B., Petr, F., and Ondrej, H., ZigBee technology and device design. Proceeding of the International Conference on Networking, International Conference on Systems and International Conference on Mobile Communications and Learning Technologies, 129, 2006. Ondrej, S., Zdenek, B., Petr, F., and Ondrej, H., ZigBee technology and device design. Proceeding of the International Conference on Networking, International Conference on Systems and International Conference on Mobile Communications and Learning Technologies, 129, 2006.
20.
go back to reference Gutierrez, J. A., Naeve, M., Callaway, E., Bourgeois, M., Mitter, V., and Heile, B., IEEE 802.115.4: A developing standard for low power, low cost wireless personal area networks. IEEE Netw. 15(5):12–19, 2001.CrossRef Gutierrez, J. A., Naeve, M., Callaway, E., Bourgeois, M., Mitter, V., and Heile, B., IEEE 802.115.4: A developing standard for low power, low cost wireless personal area networks. IEEE Netw. 15(5):12–19, 2001.CrossRef
21.
go back to reference Geer, D., Users make a beeline for ZigBee sensor technology. IEEE Comput. Soc. 38(12):16–19, 2005.CrossRef Geer, D., Users make a beeline for ZigBee sensor technology. IEEE Comput. Soc. 38(12):16–19, 2005.CrossRef
22.
go back to reference Vossiek, M., Wiebking, L., Gulden, P., Wieghardt, J., Hoffmann, C., and Heide, P., Wireless local positioning. IEEE Microw. Mag. 4(4):77–86, 2003.CrossRef Vossiek, M., Wiebking, L., Gulden, P., Wieghardt, J., Hoffmann, C., and Heide, P., Wireless local positioning. IEEE Microw. Mag. 4(4):77–86, 2003.CrossRef
23.
go back to reference Hohlt, B., Doherty, L., and Brewer, E., Flexible power scheduling for sensor network. Proceeding of the 3rd International Symposium on Information Processing in Sensor Network, 205–214, 2004. Hohlt, B., Doherty, L., and Brewer, E., Flexible power scheduling for sensor network. Proceeding of the 3rd International Symposium on Information Processing in Sensor Network, 205–214, 2004.
24.
go back to reference Khan, N. A., McAlister, F. A., Lewanczuk, R. Z., Touyz, R. M., Padwal, R., Rabkin, S. W., et al., The 2005 Canadian hypertension education program recommendations for the management of hypertension: Part II—Therapy. Can. J. Cardiol. 21:657–672, 2005. Khan, N. A., McAlister, F. A., Lewanczuk, R. Z., Touyz, R. M., Padwal, R., Rabkin, S. W., et al., The 2005 Canadian hypertension education program recommendations for the management of hypertension: Part II—Therapy. Can. J. Cardiol. 21:657–672, 2005.
25.
go back to reference XBee®/XBee-PRO® DigiMesh™ 2.4 OEM RF Modules, User guide, Digi Internaitonal, Inc., 2008. XBee®/XBee-PRO® DigiMesh™ 2.4 OEM RF Modules, User guide, Digi Internaitonal, Inc., 2008.
26.
go back to reference Cao, L., Jiang, W., and Zhang, Z., Networked wireless meter reading system based on ZigBee technology. Control and Decision Conference, 3455–3460, 2008. Cao, L., Jiang, W., and Zhang, Z., Networked wireless meter reading system based on ZigBee technology. Control and Decision Conference, 3455–3460, 2008.
Metadata
Title
Development of a Telecare System Based on ZigBee Mesh Network for Monitoring Blood Pressure of Patients with Hemodialysis in Health Care Centers
Authors
Yi-Chun Du
You-Yun Lee
Yun-Yuan Lu
Chia-Hung Lin
Ming-Jei Wu
Chung-Lin Chen
Tainsong Chen
Publication date
01-10-2011
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 5/2011
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-010-9513-0

Other articles of this Issue 5/2011

Journal of Medical Systems 5/2011 Go to the issue