Skip to main content
Top
Published in: Journal of Medical Systems 5/2011

01-10-2011 | Original Paper

Calcaneal Osteotomy Preoperative Planning System with 3D Full-Sized Computer-Assisted Technology

Authors: Yi-Jiun Chou, Shuh-Ping Sun, Hsin-Hua Liu

Published in: Journal of Medical Systems | Issue 5/2011

Login to get access

Abstract

In this study, we developed a CT-based computer-assisted pre-operative planning and simulating system for the calcaneal osteotomy by integrating different software’s function. This system uses the full-scaled 3D reverse engineering technique in designing and developing preoperative planning modules for the calcaneal osteotomy surgery. The planning system presents a real-sized three-dimensional image of the calcaneus, and provides detailed interior measurements of the calcaneus from various cutting planes. This study applied computer-assisted technology to integrate different software’s function to a surgical planning system. These functions include 3-D image model capturing, cutting, moving, rotating and measurement for relevant foot anatomy, and can be integrated as the user’s function. Furthermore, the system is computer-based and computer-assisted technology. Surgeons can utilize it as part of preoperative planning to develop efficient operative procedures. This system also has a database that can be updated and extended and will provide the clinical cases to different users for experienced based learning.
Literature
1.
go back to reference Sun, S. P., Chou, Y. J., Liu, S. W., Chen, Y. L., The full scale 3D computer-aided clinical simulation system of the osteotomy surgery for the calcaneus. Biomedical Engineering Society Annual Symposium. Taiwan 2-098, 2005. Sun, S. P., Chou, Y. J., Liu, S. W., Chen, Y. L., The full scale 3D computer-aided clinical simulation system of the osteotomy surgery for the calcaneus. Biomedical Engineering Society Annual Symposium. Taiwan 2-098, 2005.
2.
go back to reference Su, T. S., Chen, D. K., Sung, W. H., Jiang, C. F., Sun, S. P., and Wu, C. J., Development of a virtual simulation environment for radiation treatment planning. J. Med. Biol. Eng. 25(2):61–66, 2005. Su, T. S., Chen, D. K., Sung, W. H., Jiang, C. F., Sun, S. P., and Wu, C. J., Development of a virtual simulation environment for radiation treatment planning. J. Med. Biol. Eng. 25(2):61–66, 2005.
3.
go back to reference Jupiter, J. B., Ruder, J., and Roth, D. A., Computer-generated bone models in the planning of osteotomy of multidirectional distal radius malunions. J. Hand Surg.-Am. 17(3):406–415, 1992.CrossRef Jupiter, J. B., Ruder, J., and Roth, D. A., Computer-generated bone models in the planning of osteotomy of multidirectional distal radius malunions. J. Hand Surg.-Am. 17(3):406–415, 1992.CrossRef
4.
go back to reference Caponetti, L., and Fanelli, A. M., Computer-aided simulation for bone surgery. IEEE Comput. Graph. Appl. 13(6):86–92, 1993.CrossRef Caponetti, L., and Fanelli, A. M., Computer-aided simulation for bone surgery. IEEE Comput. Graph. Appl. 13(6):86–92, 1993.CrossRef
5.
go back to reference Sébastien, S., and Fabrice, C., Accuracy evaluation of a CAS system: laboratory protocol and results with 6D localizers, and clinical experiences in otorhinolaryngology. Comput. Aided Surg. 6(3):1–13, 2001. Sébastien, S., and Fabrice, C., Accuracy evaluation of a CAS system: laboratory protocol and results with 6D localizers, and clinical experiences in otorhinolaryngology. Comput. Aided Surg. 6(3):1–13, 2001.
6.
go back to reference Stindel, E., Briard, J. L., Merloz, P., Plaweski, S., Dubrana, F., Lefevre, C., Troccaz, J., Bone morphing: 3D morphological data for total knee arthroplasty. Comput. Aided Surg. 156–68, 2002. Stindel, E., Briard, J. L., Merloz, P., Plaweski, S., Dubrana, F., Lefevre, C., Troccaz, J., Bone morphing: 3D morphological data for total knee arthroplasty. Comput. Aided Surg. 156–68, 2002.
7.
go back to reference Messmer, P., Long, G., Suhm, N., Regazzoni, P., and Jacob, A. L., Volumetric model determination of the tibia based on 2D radiographs using a 2D/3D database. Comput. Aided Surg. 6(4):183–194, 2001.CrossRef Messmer, P., Long, G., Suhm, N., Regazzoni, P., and Jacob, A. L., Volumetric model determination of the tibia based on 2D radiographs using a 2D/3D database. Comput. Aided Surg. 6(4):183–194, 2001.CrossRef
8.
go back to reference Gert, S., Hans, K., Alexander, G., and Robert, K., Stereolithography versus milled three-dimensional models: comparison of production method, indication, and accuracy. Comput. Aided Surg. 3(5):248–256, 1998. Gert, S., Hans, K., Alexander, G., and Robert, K., Stereolithography versus milled three-dimensional models: comparison of production method, indication, and accuracy. Comput. Aided Surg. 3(5):248–256, 1998.
9.
go back to reference Grass, M., Koppe, R., Klotz, E., Proksa, R., Kuhn, M. H., Aerts, H., Beek, J., and Kemkers, R., Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data. Comput Med Imaging Graph 23:311–321, 1999.CrossRef Grass, M., Koppe, R., Klotz, E., Proksa, R., Kuhn, M. H., Aerts, H., Beek, J., and Kemkers, R., Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data. Comput Med Imaging Graph 23:311–321, 1999.CrossRef
10.
go back to reference Ashoke, S. T., David, L. W., Modeling and optimization of rotational C-Arm stereoscopic X-Ray angiography. IEEE Trans. Med. Imag. 18(7), 1999. Ashoke, S. T., David, L. W., Modeling and optimization of rotational C-Arm stereoscopic X-Ray angiography. IEEE Trans. Med. Imag. 18(7), 1999.
11.
go back to reference Wirth, S., Euler, E., Linsenmaier, U., Rock, C., Kotsianos, D., Brandl, R., Mutschler, W., and Pfeifer, K. J., C-arm based computed tomography—A comparative study. Int. Congr. Ser. 1230:429–435, 2001.CrossRef Wirth, S., Euler, E., Linsenmaier, U., Rock, C., Kotsianos, D., Brandl, R., Mutschler, W., and Pfeifer, K. J., C-arm based computed tomography—A comparative study. Int. Congr. Ser. 1230:429–435, 2001.CrossRef
12.
go back to reference Bra, E. M., Tveit, K., Junk, S., Aamodt, A., Anda, S., and Terjesen, T., The role of fuoroscopy in avoiding rotational deformity of treated femoral shaft fractures: an anatomical and clinical study. Injury Int. J. Care Injured 31:311–315, 2000. Bra, E. M., Tveit, K., Junk, S., Aamodt, A., Anda, S., and Terjesen, T., The role of fuoroscopy in avoiding rotational deformity of treated femoral shaft fractures: an anatomical and clinical study. Injury Int. J. Care Injured 31:311–315, 2000.
13.
go back to reference Klein, M., Lueth, T., Hein, A., Stien, M., Schermeier, O., Weber, S., Menneking, H., Schwerdtner, O., and Bier, J., Robot-assisted insertion of craniofacial implants—clinical experience. Int. Congr. Ser. 1230:131–137, 2001.CrossRef Klein, M., Lueth, T., Hein, A., Stien, M., Schermeier, O., Weber, S., Menneking, H., Schwerdtner, O., and Bier, J., Robot-assisted insertion of craniofacial implants—clinical experience. Int. Congr. Ser. 1230:131–137, 2001.CrossRef
14.
go back to reference Rammelt, S., and Zwipp, H., Calcaneus fractures: facts, controversies and recent developments. Injury Int. J. Care Injured 35:443–461, 2004. Rammelt, S., and Zwipp, H., Calcaneus fractures: facts, controversies and recent developments. Injury Int. J. Care Injured 35:443–461, 2004.
15.
go back to reference Sun, S. P., and Wu, C. J., The application of full scale 3D anthropometric digital model system in radio therapy positioning and verification. Journal of Biomedical Engineering Applications Basis and Communications 16(4):173–179, 2004.CrossRef Sun, S. P., and Wu, C. J., The application of full scale 3D anthropometric digital model system in radio therapy positioning and verification. Journal of Biomedical Engineering Applications Basis and Communications 16(4):173–179, 2004.CrossRef
16.
go back to reference Sun, S. P., Hsu, K. W., and Chen, J. S., The stable status evaluation for female breast implant surgery by calculating related physics parameters. Comput. Methods Programs Biomed., 2007. doi:10.1016/j.cmpb.2007.11.013. Sun, S. P., Hsu, K. W., and Chen, J. S., The stable status evaluation for female breast implant surgery by calculating related physics parameters. Comput. Methods Programs Biomed., 2007. doi:10.​1016/​j.​cmpb.​2007.​11.​013.
Metadata
Title
Calcaneal Osteotomy Preoperative Planning System with 3D Full-Sized Computer-Assisted Technology
Authors
Yi-Jiun Chou
Shuh-Ping Sun
Hsin-Hua Liu
Publication date
01-10-2011
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 5/2011
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-010-9465-4

Other articles of this Issue 5/2011

Journal of Medical Systems 5/2011 Go to the issue