Skip to main content
Top
Published in: Journal of Medical Systems 4/2011

01-08-2011 | Original Paper

Detecting Sleep Apnea by Heart Rate Variability Analysis: Assessing the Validity of Databases and Algorithms

Authors: María J. Lado, Xosé A. Vila, Leandro Rodríguez-Liñares, Arturo J. Méndez, David N. Olivieri, Paulo Félix

Published in: Journal of Medical Systems | Issue 4/2011

Login to get access

Abstract

Obstructive sleep apnea (OSA) is a serious disorder caused by intermittent airway obstruction which may have dangerous impact on daily living activities. Heart rate variability (HRV) analysis could be used for diagnosing OSA, since this disease affects HRV during sleep. In order to validate different algorithms developed for detecting OSA employing HRV analysis, several public or proprietary data collections have been employed for different research groups. However, for validation purposes, it is obvious and evident the lack of a common standard database, worldwide recognized and accepted by the scientific community. In this paper, different algorithms employing HRV analysis were applied over diverse public and proprietary databases for detecting OSA, and the outcomes were validated in terms of a statistical analysis. Results indicate that the use of a specific database may strongly affect the performance of the algorithms, due to differences in methodologies of processing. Our results suggest that researchers must strongly take into consideration the database used when quoting their results, since selected cases are highly database dependent and would bias conclusions.
Literature
1.
go back to reference Young, T., Peppard, P. E., and Gottlieb, D. J., Epidemiology of obstructive sleep apnea. A population health perspective. Am. J. Respir. Crit. Care Med. 165:1217–1219, 2002.CrossRef Young, T., Peppard, P. E., and Gottlieb, D. J., Epidemiology of obstructive sleep apnea. A population health perspective. Am. J. Respir. Crit. Care Med. 165:1217–1219, 2002.CrossRef
2.
go back to reference Strohl, K., and Redline, S., Recognition of obstructive sleep apnea. Am. J. Respir. Crit. Care Med. 154:274–289, 1996. Strohl, K., and Redline, S., Recognition of obstructive sleep apnea. Am. J. Respir. Crit. Care Med. 154:274–289, 1996.
3.
go back to reference Hossen, A., Ghunaimi, B. A., and Hassan, M. O., Subband decomposition soft-decision algorithm for heart rate variability analysis in patients with obstructive sleep apnea and normal controls. Signal. Proc. 83:95–106, 2005.CrossRef Hossen, A., Ghunaimi, B. A., and Hassan, M. O., Subband decomposition soft-decision algorithm for heart rate variability analysis in patients with obstructive sleep apnea and normal controls. Signal. Proc. 83:95–106, 2005.CrossRef
4.
go back to reference Roche, F., Pichot, V., Sforza, E., Court-Fortune, I., Costes, F., Garet, M., and Barthélémy, J. C., Predicting sleep apnea syndrome from heart period: a time-frequency wavelet analysis. Eur. Respir. J. 22:937–942, 2003.CrossRef Roche, F., Pichot, V., Sforza, E., Court-Fortune, I., Costes, F., Garet, M., and Barthélémy, J. C., Predicting sleep apnea syndrome from heart period: a time-frequency wavelet analysis. Eur. Respir. J. 22:937–942, 2003.CrossRef
5.
go back to reference Günes, S., Polat, K., and Yosunkaya, S., Multi-class f-score feature selection approach to classification of obstructive sleep apnea syndrome. Expert Syst. Appl. (in press), 2009. Günes, S., Polat, K., and Yosunkaya, S., Multi-class f-score feature selection approach to classification of obstructive sleep apnea syndrome. Expert Syst. Appl. (in press), 2009.
6.
go back to reference Bigger, J. T., Fleiss, J. L., Steinman, R. C., Rolnitzky, L. M., Kleiger, R. E., and Rottman, J. N., Frequency domain measures of heart period variability and mortality after myocardial infarction. Circulation. 85:164–171, 1992. Bigger, J. T., Fleiss, J. L., Steinman, R. C., Rolnitzky, L. M., Kleiger, R. E., and Rottman, J. N., Frequency domain measures of heart period variability and mortality after myocardial infarction. Circulation. 85:164–171, 1992.
7.
go back to reference Vinik, A. I., and Ziegler, D., Diabetic cardiovascular autonomic neuropathy. Circulation. 115:387–397, 2007.CrossRef Vinik, A. I., and Ziegler, D., Diabetic cardiovascular autonomic neuropathy. Circulation. 115:387–397, 2007.CrossRef
8.
go back to reference Narkiewicz, K., Montano, N., Cogliati, C., van de Borne, P. J. H., Dyken, M. E., and Somers, V. K., Altered cardiovascular variability in obstructive sleep apnea. Circulation. 98:1071–1077, 1998. Narkiewicz, K., Montano, N., Cogliati, C., van de Borne, P. J. H., Dyken, M. E., and Somers, V. K., Altered cardiovascular variability in obstructive sleep apnea. Circulation. 98:1071–1077, 1998.
9.
go back to reference Gula, L. J., Krahn, A. D., Skanes, A., Ferguson, K. A., George, C., Yee, R., and Klein, G. J., Heart rate variability in obstructive sleep apnea: a prospective study and frequency domain analysis. ANE. 8:144–149, 2003. Gula, L. J., Krahn, A. D., Skanes, A., Ferguson, K. A., George, C., Yee, R., and Klein, G. J., Heart rate variability in obstructive sleep apnea: a prospective study and frequency domain analysis. ANE. 8:144–149, 2003.
10.
go back to reference Penzel, T., Kantelhardt, J. W., Grote, L., Peter, J. H., and Bunde, A., Comparison of detrended fluctuations and spectral analysis for heart rate variability in sleep and sleep apnea. IEEE Trans. Biomed. Eng. 50:1143–1151, 2003.CrossRef Penzel, T., Kantelhardt, J. W., Grote, L., Peter, J. H., and Bunde, A., Comparison of detrended fluctuations and spectral analysis for heart rate variability in sleep and sleep apnea. IEEE Trans. Biomed. Eng. 50:1143–1151, 2003.CrossRef
11.
go back to reference Drinnan, M. J., Allen, J., Langley, P., and Murray, A., Detection of sleep apnoea from frequency analysis of heart rate variability. Comput. Cardiol. 27:263–269, 2000. Drinnan, M. J., Allen, J., Langley, P., and Murray, A., Detection of sleep apnoea from frequency analysis of heart rate variability. Comput. Cardiol. 27:263–269, 2000.
12.
go back to reference Otero, A., Dapena, S. F., Félix, P., Presedo, J., and Tarascó, M., A screening test for obstructive sleep apnea that can be performed at the patient’s home. WISP2009-6th IEEE Int. Symp. Intell. Signal. Proc. 199–204, 2009. Otero, A., Dapena, S. F., Félix, P., Presedo, J., and Tarascó, M., A screening test for obstructive sleep apnea that can be performed at the patient’s home. WISP2009-6th IEEE Int. Symp. Intell. Signal. Proc. 199–204, 2009.
13.
go back to reference Nishikawa, R. M., Giger, M. L., Doi, K., Metz, C. E., Yin, F., Viborny, C. J., and Schmidt, R. A., Effect of case selection on the performance of computer-aided detection schemes. Med. Phys. 21:265–269, 1994.CrossRef Nishikawa, R. M., Giger, M. L., Doi, K., Metz, C. E., Yin, F., Viborny, C. J., and Schmidt, R. A., Effect of case selection on the performance of computer-aided detection schemes. Med. Phys. 21:265–269, 1994.CrossRef
14.
go back to reference Vila, J., Barro, S., Presedo, J., Ruiz, R., and Palácios, F., Analysis of heart rate variability with evenly spaced time values. Proc. 14th Annual Int. Conf. IEEE EMBS. 575–576, 1992. Vila, J., Barro, S., Presedo, J., Ruiz, R., and Palácios, F., Analysis of heart rate variability with evenly spaced time values. Proc. 14th Annual Int. Conf. IEEE EMBS. 575–576, 1992.
15.
go back to reference Shinar, Z., Baharav, A., and Akselrod, S., Obstructive sleep apnea detection based on electrocardiogram analysis. Comput. Cardiol. 27:757–760, 2000. Shinar, Z., Baharav, A., and Akselrod, S., Obstructive sleep apnea detection based on electrocardiogram analysis. Comput. Cardiol. 27:757–760, 2000.
16.
go back to reference Schrader, M., Zywietz, C., von Einem, V., Widiger, B., and Joseph, G., Detection of sleep apnea in single channel ECGs from the PhysioNet data base. Comput. Cardiol. 27:259–262, 2000. Schrader, M., Zywietz, C., von Einem, V., Widiger, B., and Joseph, G., Detection of sleep apnea in single channel ECGs from the PhysioNet data base. Comput. Cardiol. 27:259–262, 2000.
17.
go back to reference Mendez, M. O., Ruini, D. D., Villantieri, O. P., Matteucci, M., Penzel, T., Cerutti, S., and Bianchi, A. M., Detection of sleep apnea from surface ECG based on features extracted by an autoregressive model. Proc. IEEE EMBS. 6105–6108, 2007. Mendez, M. O., Ruini, D. D., Villantieri, O. P., Matteucci, M., Penzel, T., Cerutti, S., and Bianchi, A. M., Detection of sleep apnea from surface ECG based on features extracted by an autoregressive model. Proc. IEEE EMBS. 6105–6108, 2007.
18.
go back to reference Al-Angari, H. M., and Sahakian, A. V., Use of sample entropy approach to study heart rate variability in obstructive sleep apnea syndrome. IEEE Trans. Biomed. Eng. 54:1900–1904, 2007.CrossRef Al-Angari, H. M., and Sahakian, A. V., Use of sample entropy approach to study heart rate variability in obstructive sleep apnea syndrome. IEEE Trans. Biomed. Eng. 54:1900–1904, 2007.CrossRef
19.
go back to reference Ichimaru, Y., and Moody, G. B., Development of the polysomnographic database on CD-ROM. Psych. Clin. Neurosci. 53:175–177, 1999.CrossRef Ichimaru, Y., and Moody, G. B., Development of the polysomnographic database on CD-ROM. Psych. Clin. Neurosci. 53:175–177, 1999.CrossRef
20.
go back to reference Vila, X. A., Lado, M. J., Méndez, A. J., Olivieri, D. N., and Rodríguez-Liñares, L., An R package for heart rate variability analysis. WISP2009-6th IEEE Int. Symp. Intell. Signal. Proc. 217–222, 2009. Vila, X. A., Lado, M. J., Méndez, A. J., Olivieri, D. N., and Rodríguez-Liñares, L., An R package for heart rate variability analysis. WISP2009-6th IEEE Int. Symp. Intell. Signal. Proc. 217–222, 2009.
21.
go back to reference Vila, J., Palacios, F., Presedo, J., Fernández-Delgado, M., Félix, P., and Barro, S., Time-frequency analysis of heart-rate variability. IEEE Eng. Med. Biol. Mag. 16:119–125, 1997.CrossRef Vila, J., Palacios, F., Presedo, J., Fernández-Delgado, M., Félix, P., and Barro, S., Time-frequency analysis of heart-rate variability. IEEE Eng. Med. Biol. Mag. 16:119–125, 1997.CrossRef
22.
go back to reference Grafen, A., and Hails, R., Modern statistics for the life sciences. Oxford University Press: New York, 2002. Grafen, A., and Hails, R., Modern statistics for the life sciences. Oxford University Press: New York, 2002.
23.
go back to reference Park, D. H., Shin, C. J., Hong, S. C., Yu, J., Ryu, S. H., Kim, E. J., Shin, H. B., and Shin, B. H., Correlation between the severity of obstructive sleep apnea and heart rate variability indices. J. Korean Med. Sci. 23:226–231, 2008.CrossRef Park, D. H., Shin, C. J., Hong, S. C., Yu, J., Ryu, S. H., Kim, E. J., Shin, H. B., and Shin, B. H., Correlation between the severity of obstructive sleep apnea and heart rate variability indices. J. Korean Med. Sci. 23:226–231, 2008.CrossRef
Metadata
Title
Detecting Sleep Apnea by Heart Rate Variability Analysis: Assessing the Validity of Databases and Algorithms
Authors
María J. Lado
Xosé A. Vila
Leandro Rodríguez-Liñares
Arturo J. Méndez
David N. Olivieri
Paulo Félix
Publication date
01-08-2011
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 4/2011
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-009-9383-5

Other articles of this Issue 4/2011

Journal of Medical Systems 4/2011 Go to the issue