Published in: Journal of Medical Systems 4/2011

01-08-2011 | Original Paper

Evaluation of a Novel Integrated Sensor System for Synchronous Measurement of Cardiac Vibrations and Cardiac Potentials

Authors: Yindar Chuo, Kouhyar Tavakolian, Bozena Kaminska

Published in: Journal of Medical Systems | Issue 4/2011

Login to get access

Abstract

The measurement of human body vibrations as a result of heart beating, simultaneously with cardiac potentials have been demonstrated in past studies to bring additional value to diagnostic cardiology through the detection of irregularities in the mechanical movement of the heart. The equipment currently available to the medical community is either large and bulky or difficult to synchronize. To address this problem, a novel integrated sensor system has been developed to record cardiac vibration and cardiac potential simultaneously and synchronously from a single compact site on the chest. The developed sensor system is lightweight, small in size, and suitable for mounting on active moving patients. The sensor is evaluated for its adequacy in measuring cardiac vibrations and potentials. In this evaluation, 45 independent signal recording are studied from 15 volunteers, and the morphology of the recorded signals are analyzed qualitatively (by visual inspection) and quantitatively (by computational methods) against larger devices used in established cardiac vibration studies (reference devices). It is found that the cardiac vibration signals acquired by the integrated sensor has 92.37% and 81.76% identically identifiable systolic and diastolic cardiac complexes, respectively, when compared to the cardiac vibration signals recorded simultaneously from the reference device. Further, the cardiac potential signals acquired by the integrated sensor show a high correlation coefficient of 0.8912 and a high estimated signal-to-noise-ratio of 22.00 dB when compared to the reference electrocardiograph (non-standard leads) acquired through a common clinical machine. The results suggest that the tiny, wearable, integrated sensor system that synchronously measures cardiac vibrations and cardiac potentials may be practical for use as an alternative or assistive cardiac diagnostic tool.
Literature
1.
go back to reference McKay, W., Gregson, P., McKay, B., and Militzer, J., Sternal acceleration ballistocardiography and arterial pressure wave analysis to determine stroke volume. Clin. Invest. Med. 22 (1)4–14, 1999. McKay, W., Gregson, P., McKay, B., and Militzer, J., Sternal acceleration ballistocardiography and arterial pressure wave analysis to determine stroke volume. Clin. Invest. Med. 22 (1)4–14, 1999.
2.
go back to reference Salerno, D., and Zanetti, J., Seismocardiography: A new technique for recording cardiac vibrations. J. Cardiovasc Technol. 9:111–117, 1990. Salerno, D., and Zanetti, J., Seismocardiography: A new technique for recording cardiac vibrations. J. Cardiovasc Technol. 9:111–117, 1990.
3.
go back to reference Tavakolian, K., Zadeh, F.M., Chuo, Y., Vaseghi, A., and Kaminska, B., Development of a novel contactless mechanocardiograph device. Int. J. Telemed. Appl. 436870, 2008. Tavakolian, K., Zadeh, F.M., Chuo, Y., Vaseghi, A., and Kaminska, B., Development of a novel contactless mechanocardiograph device. Int. J. Telemed. Appl. 436870, 2008.
4.
go back to reference Tavakolian, K., Vaseghi, A., and Kaminska, B., Improvement of ballistocardiogram processing by inclusion of respiration information. J. Physiol. Meas. IOP. 29 (7)771–781, 2008.CrossRef Tavakolian, K., Vaseghi, A., and Kaminska, B., Improvement of ballistocardiogram processing by inclusion of respiration information. J. Physiol. Meas. IOP. 29 (7)771–781, 2008.CrossRef
5.
go back to reference Crow, S. R., Hannan, P., Jacobs, D., Hedquist, L., and Salerno, D. M., Relationship between seismocardiogram and echocardiogram for events in the cardiac cycle. Am. J. Noninvas. Cardiol. 8:39–46, 1994. Crow, S. R., Hannan, P., Jacobs, D., Hedquist, L., and Salerno, D. M., Relationship between seismocardiogram and echocardiogram for events in the cardiac cycle. Am. J. Noninvas. Cardiol. 8:39–46, 1994.
6.
go back to reference Castiglioni, P., Faini, A., Parati, G., Di Rienzo, M., Wearable seismocardiography. In: Proc 29th Ann Intl Conf IEEE EMBS, pp 3954–3957, 2007. Castiglioni, P., Faini, A., Parati, G., Di Rienzo, M., Wearable seismocardiography. In: Proc 29th Ann Intl Conf IEEE EMBS, pp 3954–3957, 2007.
7.
go back to reference Starr, I., and Wood, E. C., Twenty-year studies with the ballistocardiograph, the relation between the amplitude of the first record of ‘healthy’ adults and eventual mortality and morbidity form heart disease. Circulation. 23:714–732, 1961. Starr, I., and Wood, E. C., Twenty-year studies with the ballistocardiograph, the relation between the amplitude of the first record of ‘healthy’ adults and eventual mortality and morbidity form heart disease. Circulation. 23:714–732, 1961.
8.
go back to reference Eblen-Zajjur, A., A simple ballistocardiography system for medical cardiovascular physiology course. Adv. Physiol. Educ. 27:224–229, 2003.CrossRef Eblen-Zajjur, A., A simple ballistocardiography system for medical cardiovascular physiology course. Adv. Physiol. Educ. 27:224–229, 2003.CrossRef
9.
go back to reference Elliott, R. V., Acceleration ballistocardiography: Design, construction, and application of a new instrument. Circulation. 9:281–291, 1954. Elliott, R. V., Acceleration ballistocardiography: Design, construction, and application of a new instrument. Circulation. 9:281–291, 1954.
10.
go back to reference Starr, I., and Noordergraaf, A., Ballistocardiography in Cardiovascular Research. Lippincott, Philadelphia, 1967. Starr, I., and Noordergraaf, A., Ballistocardiography in Cardiovascular Research. Lippincott, Philadelphia, 1967.
11.
go back to reference Chuo, Y., and Kaminska, B., Multiparameter single locus integrated multilayer polymer microsensor system. BIODEVICES. 1:36–43, 2008. Chuo, Y., and Kaminska, B., Multiparameter single locus integrated multilayer polymer microsensor system. BIODEVICES. 1:36–43, 2008.
12.
go back to reference Chuo, Y., and Kaminska, B., Sensor layer of a multiparameter single-point integrated system. IEEE Trans. Biomed. Circuits Syst. 3 (4)229–240, 2009.CrossRef Chuo, Y., and Kaminska, B., Sensor layer of a multiparameter single-point integrated system. IEEE Trans. Biomed. Circuits Syst. 3 (4)229–240, 2009.CrossRef
13.
go back to reference Afonso, V. X., Tompkins, W. J., Nguyen, T. Q., and Luo, S., ECG beat detection using filter banks. IEEE TBME. 46:192–202, 1999. Afonso, V. X., Tompkins, W. J., Nguyen, T. Q., and Luo, S., ECG beat detection using filter banks. IEEE TBME. 46:192–202, 1999.
14.
go back to reference Bershad, N. J., and Rockmore, A. J., On estimating signal to noise ratio using the sample correlation coefficient. IEEE Trans. Inf. Theory. 20:112–113, 1974.MATHCrossRef Bershad, N. J., and Rockmore, A. J., On estimating signal to noise ratio using the sample correlation coefficient. IEEE Trans. Inf. Theory. 20:112–113, 1974.MATHCrossRef
Metadata
Title
Evaluation of a Novel Integrated Sensor System for Synchronous Measurement of Cardiac Vibrations and Cardiac Potentials
Authors
Yindar Chuo
Kouhyar Tavakolian
Bozena Kaminska
Publication date
01-08-2011
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 4/2011
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-009-9380-8

Other articles of this Issue 4/2011

Journal of Medical Systems 4/2011 Go to the issue