Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 6/2020

01-12-2020 | Brief Communication

Optimized electrical bioimpedance measurements of abdominal wall on a porcine model for the continuous non-invasive assessment of intra-abdominal pressure

Authors: Marcelo David, Omer Amran, Aviad Peretz, Aviad Raviv, Francisco Pracca

Published in: Journal of Clinical Monitoring and Computing | Issue 6/2020

Login to get access

Abstract

This work describes the optimization of electrical bioimpedance measurements for indirect intra-abdominal pressure (IAP) assessment. The experimental run was performed on a female Sus scrofa domesticus (domestic pig). Different values of IAP were induced by inflation of the abdominal cavity, using a trocar placed near the umbilicus over the linea alba. The whole experiment was run within 1 h of the subject being sacrificed. The abdominal wall thickness was measured at an IAP of 5 mmHg. An exponential trend linking between the bioimpedance values at 99.8 kHz and the IAP was found. Non-optimized electrode placement presented a strongly reduced sensitivity to IAP changes above 7 mmHg. Upon optimization and placing the electrodes with a separation of about 3.6 times the measured abdominal wall thickness, the sensitivity for high IAP drastically increased, allowing continuous non-invasive monitoring of IAP, confirming the optimization method proposed in this work.
Literature
1.
go back to reference De Waele JJ, De Laet I, Kirkpatrick AW, Hoste E. Intra-abdominal hypertension and abdominal compartment syndrome. Am J Kidney Dis. 2011;57(1):159–69.CrossRef De Waele JJ, De Laet I, Kirkpatrick AW, Hoste E. Intra-abdominal hypertension and abdominal compartment syndrome. Am J Kidney Dis. 2011;57(1):159–69.CrossRef
2.
go back to reference Malbrain ML, Cheatham ML, Kirkpatrick A, Sugrue M, Parr M, De Waele J, Balogh Z, Leppäniemi A, Olvera C, Ivatury R, D’Amours S, Wendon J, Hillman K, Johansson K, Kolkman K, Wilmer A. results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. I. Definitions. Intensive Care Med. 2006;32(11):1722–32.CrossRef Malbrain ML, Cheatham ML, Kirkpatrick A, Sugrue M, Parr M, De Waele J, Balogh Z, Leppäniemi A, Olvera C, Ivatury R, D’Amours S, Wendon J, Hillman K, Johansson K, Kolkman K, Wilmer A. results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. I. Definitions. Intensive Care Med. 2006;32(11):1722–32.CrossRef
3.
go back to reference Sugrue M, Bauman A, Jones F, Bishop G, Flabouris A, Parr M, Stewart A, Hillman K, Deane SA. Clinical examination is an inaccurate predictor of intraabdominal pressure. World J Surg. 2002;26(12):1428–31.CrossRef Sugrue M, Bauman A, Jones F, Bishop G, Flabouris A, Parr M, Stewart A, Hillman K, Deane SA. Clinical examination is an inaccurate predictor of intraabdominal pressure. World J Surg. 2002;26(12):1428–31.CrossRef
4.
go back to reference Malbrain ML, Roberts DJ, De Laet I, De Waele JJ, Sugrue M, Schachtrupp A, Duchesne J, Van Ramshorst G, De Keulenaer B, Kirkpatrick AW, Ahmadi-Noorbakhsh S, Mulier J, Ivatury R, Pracca F, Wise R, Pelosi P. The role of abdominal compliance, the neglected parameter in critically ill patients - a consensus review of 16. Part 1: definitions and pathophysiology. Anaesthesiol Intensive Ther. 2014;46(5):392–405.CrossRef Malbrain ML, Roberts DJ, De Laet I, De Waele JJ, Sugrue M, Schachtrupp A, Duchesne J, Van Ramshorst G, De Keulenaer B, Kirkpatrick AW, Ahmadi-Noorbakhsh S, Mulier J, Ivatury R, Pracca F, Wise R, Pelosi P. The role of abdominal compliance, the neglected parameter in critically ill patients - a consensus review of 16. Part 1: definitions and pathophysiology. Anaesthesiol Intensive Ther. 2014;46(5):392–405.CrossRef
5.
go back to reference Malbrain ML, De Laet I, De Waele JJ, Sugrue M, Schachtrupp A, Duchesne J, Van Ramshorst G, De Keulenaer B, Kirkpatrick AW, Ahmadi-Noorbakhsh S, Mulier J, Pelosi P, Ivatury R, Pracca F, David M, Roberts DJ. The role of abdominal compliance, the neglected parameter in critically ill patients - a consensus review of 16. Part 2: measurement techniques and management recommendations. Anaesthesiol Intensive Ther. 2014;46(5):406–32.CrossRef Malbrain ML, De Laet I, De Waele JJ, Sugrue M, Schachtrupp A, Duchesne J, Van Ramshorst G, De Keulenaer B, Kirkpatrick AW, Ahmadi-Noorbakhsh S, Mulier J, Pelosi P, Ivatury R, Pracca F, David M, Roberts DJ. The role of abdominal compliance, the neglected parameter in critically ill patients - a consensus review of 16. Part 2: measurement techniques and management recommendations. Anaesthesiol Intensive Ther. 2014;46(5):406–32.CrossRef
6.
go back to reference David M, Pracca F, Simini F. Non-invasive negative pressure system to treat abdominal hypertension. In: Jobbágy Á (eds.). 5th European IFMBE Conference. 37. Budapest: Springer Science & Business Media 2011. p. 211–214. David M, Pracca F, Simini F. Non-invasive negative pressure system to treat abdominal hypertension. In: Jobbágy Á (eds.). 5th European IFMBE Conference. 37. Budapest: Springer Science & Business Media 2011. p. 211–214.
7.
go back to reference David M, Geido D, Pracca F, Sánchez G, Simini F. Zoppolo C Negative pressure device for intraabdominal pressure reduction. J Phys. 2007;90 CS:012035. David M, Geido D, Pracca F, Sánchez G, Simini F. Zoppolo C Negative pressure device for intraabdominal pressure reduction. J Phys. 2007;90 CS:012035.
8.
go back to reference Pracca F, Biestro A, Gorrassi J, David M, Simini F, Cancela M. ABDOPRE: an external device for the reduction of intra-abdominal pressure Preliminary clinical experience. Rev Bras Ter Intensiva. 2011;23:238–41.CrossRef Pracca F, Biestro A, Gorrassi J, David M, Simini F, Cancela M. ABDOPRE: an external device for the reduction of intra-abdominal pressure Preliminary clinical experience. Rev Bras Ter Intensiva. 2011;23:238–41.CrossRef
9.
go back to reference Pracca F, Biestro A, Moraes L, Puppo CB, Calvo SM, Gorrasi J, Cancela M. Direct measurement of intra-abdominal pressure with a solid microtranducer. J Clin Monit Comput. 2007;21(3):167–70.CrossRef Pracca F, Biestro A, Moraes L, Puppo CB, Calvo SM, Gorrasi J, Cancela M. Direct measurement of intra-abdominal pressure with a solid microtranducer. J Clin Monit Comput. 2007;21(3):167–70.CrossRef
10.
go back to reference Iberti TJ, Lieber CE, Benjamin E. Determination of Intra-Abdominal Pressure using a transurethral bladder catheter: clinical validation of the technique. Anesthesiology. 1989;70(1):47–50.CrossRef Iberti TJ, Lieber CE, Benjamin E. Determination of Intra-Abdominal Pressure using a transurethral bladder catheter: clinical validation of the technique. Anesthesiology. 1989;70(1):47–50.CrossRef
11.
go back to reference Cheatham ML, Safcsak K. Intraabdominal pressure: a revised method for measurement. J Am Coll Surg. 1998;186(5):594–5.CrossRef Cheatham ML, Safcsak K. Intraabdominal pressure: a revised method for measurement. J Am Coll Surg. 1998;186(5):594–5.CrossRef
12.
go back to reference Cheatham ML, Malbrain ML, Kirkpatrick A, Sugrue M, Parr M, Dewaele J, et al. Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. II. Recommendations. Intensive Care Med. 2006;33:951–62.CrossRef Cheatham ML, Malbrain ML, Kirkpatrick A, Sugrue M, Parr M, Dewaele J, et al. Results from the international conference of experts on intra-abdominal hypertension and abdominal compartment syndrome. II. Recommendations. Intensive Care Med. 2006;33:951–62.CrossRef
14.
go back to reference David M, Berkovich U, Pracca F. A numerical analysis towards the continuous non-invasive assessment of intra-abdominal pressure in critical patients based on bioimpedance and microwave reflectometry. In: 13th IEEE biomedical circuits and systems conference, 2017, pp. 21–24. https://doi.org/10.1109/biocas.2017.8325053. David M, Berkovich U, Pracca F. A numerical analysis towards the continuous non-invasive assessment of intra-abdominal pressure in critical patients based on bioimpedance and microwave reflectometry. In: 13th IEEE biomedical circuits and systems conference, 2017, pp. 21–24. https://​doi.​org/​10.​1109/​biocas.​2017.​8325053.
15.
go back to reference David M, Raviv A, Peretz A, Berkovich U, Pracca F. Towards a continuous non-invasive assessment of intra-abdominal pressure based on bioimpedance and microwave reflectometry: a pilot run on a porcine model. Biomed Signal Process Control. 2018;44:96–100.CrossRef David M, Raviv A, Peretz A, Berkovich U, Pracca F. Towards a continuous non-invasive assessment of intra-abdominal pressure based on bioimpedance and microwave reflectometry: a pilot run on a porcine model. Biomed Signal Process Control. 2018;44:96–100.CrossRef
16.
go back to reference Grevious MA, Cohen M, Shah SR, Rodriguez P. Structural and functional anatomy of the abdominal wall. Clin Plast Surg. 2006;33(2):169–79.CrossRef Grevious MA, Cohen M, Shah SR, Rodriguez P. Structural and functional anatomy of the abdominal wall. Clin Plast Surg. 2006;33(2):169–79.CrossRef
17.
go back to reference Caix P. Anatomy of the abdominal wall. [Article in French]. Ann Chir Plast Esthet. 1999;44(4):289–311.PubMed Caix P. Anatomy of the abdominal wall. [Article in French]. Ann Chir Plast Esthet. 1999;44(4):289–311.PubMed
18.
go back to reference Ger R. The clinical anatomy of the anterolateral abdominal wall musculature. Clin Anat. 2009;22(3):392–7.CrossRef Ger R. The clinical anatomy of the anterolateral abdominal wall musculature. Clin Anat. 2009;22(3):392–7.CrossRef
19.
go back to reference Quinn TH, Annibali R, Dalley AF II, Fitzgibbons RJ Jr. Dissection of the anterior abdominal wall and the deep inguinal region from a laparoscopic perspective. Clin Anat. 1995;8(4):245–51.CrossRef Quinn TH, Annibali R, Dalley AF II, Fitzgibbons RJ Jr. Dissection of the anterior abdominal wall and the deep inguinal region from a laparoscopic perspective. Clin Anat. 1995;8(4):245–51.CrossRef
20.
go back to reference Simini F, Bertemes-Filho P. Bioimpedance in biomedical applications and research. 1st ed. New York: Springer; 2018.CrossRef Simini F, Bertemes-Filho P. Bioimpedance in biomedical applications and research. 1st ed. New York: Springer; 2018.CrossRef
21.
go back to reference Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol. 1996;41(11):2251–69.CrossRef Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol. 1996;41(11):2251–69.CrossRef
23.
go back to reference LH Deng, SH Karagiannoglou, WI Sakkas, JC Barbenel. Effect of geometrical factors of coplanar electrodes on biomedical measurements as exemplified by the electrical impedance measurement of saline and blood. In: Proceeding of the second joint EMBS/BMES conference, 2002, pp. 1667–1668. LH Deng, SH Karagiannoglou, WI Sakkas, JC Barbenel. Effect of geometrical factors of coplanar electrodes on biomedical measurements as exemplified by the electrical impedance measurement of saline and blood. In: Proceeding of the second joint EMBS/BMES conference, 2002, pp. 1667–1668.
24.
go back to reference Clausen CH, Skands GE, Bertelsen CV, Svendsen WE. Coplanar electrode layout optimized for increased sensitivity for electrical impedance spectroscopy. Micromachines. 2015;6(1):110–20.CrossRef Clausen CH, Skands GE, Bertelsen CV, Svendsen WE. Coplanar electrode layout optimized for increased sensitivity for electrical impedance spectroscopy. Micromachines. 2015;6(1):110–20.CrossRef
25.
go back to reference G Yang, H Long, H Tian, S Luo, H Huang. Bioimpedance measurement: modeling of coplanar electrodes and impedance characterization. In: 2008 2nd International Conference on bioinformatics and biomedical engineering, Shanghai, 2008, pp. 1248–1251. G Yang, H Long, H Tian, S Luo, H Huang. Bioimpedance measurement: modeling of coplanar electrodes and impedance characterization. In: 2008 2nd International Conference on bioinformatics and biomedical engineering, Shanghai, 2008, pp. 1248–1251.
Metadata
Title
Optimized electrical bioimpedance measurements of abdominal wall on a porcine model for the continuous non-invasive assessment of intra-abdominal pressure
Authors
Marcelo David
Omer Amran
Aviad Peretz
Aviad Raviv
Francisco Pracca
Publication date
01-12-2020
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 6/2020
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-019-00441-6

Other articles of this Issue 6/2020

Journal of Clinical Monitoring and Computing 6/2020 Go to the issue