01-06-2019 | Original Research

Error-checking intraoperative arterial line blood pressures

Authors: Charles Huanghong Du, David Glick, Avery Tung

Published in: Journal of Clinical Monitoring and Computing | Issue 3/2019

Login to get access

Abstract

Electronic medical records now store a wealth of intraoperative hemodynamic data. However, analysis of such data is plagued by artifacts related to the monitoring environment. Here, we present an algorithm for automated identification of artifacts and replacement using interpolation of arterial line blood pressures. After IRB approval, minute-by-minute digital recordings of systolic, diastolic, and mean arterial pressures (MAP) obtained during anesthesia care were analyzed using predetermined metrics to identify values anomalous from adjacent neighbors. Anomalous data points were then replaced with linear interpolation of neighbors. The algorithm was then validated against manual artifact identification in 54 anesthesia records and 41,384 arterial line measurements. To assess the algorithm’s effect on data analysis, we calculated the percent of time spent with MAP below 55 mmHg and above 100 mmHg for both raw and conditioned datasets. Manual review of the dataset identified 1.23% of all pressure readings as artifactual. When compared to manual review, the algorithm identified artifacts with 87.0% sensitivity and 99.4% specificity. The average difference between manual review and algorithm in identifying the start of arterial line monitoring was 0.17, and 2.1 min for the end of monitoring. Application of the algorithm decreased the percent of time below 55 mmHg from 4.3 to 2.0% (2.1% with manual review) and time above 100 mmHg from 8.8 to 7.3% (7.3% manual). This algorithm’s performance was comparable to manual review by a human anesthesiologist and reduced the incidence of abnormal MAP values identified using a sample analysis tool.
Appendix
Available only for authorised users
Literature
4.
go back to reference Reich DL, Bennett-Guerrero E, Bodian CA, Hossain S, Winfree W, Krol M. Intraoperative tachycardia and hypertension are independently associated with adverse outcome in noncardiac surgery of long duration. Anesth Analg. 2002;95(2):273–7.PubMed Reich DL, Bennett-Guerrero E, Bodian CA, Hossain S, Winfree W, Krol M. Intraoperative tachycardia and hypertension are independently associated with adverse outcome in noncardiac surgery of long duration. Anesth Analg. 2002;95(2):273–7.PubMed
5.
go back to reference Salmasi V, Maheshwari K, Yang D, Mascha EJ, Singh A, Sessler DI, Kurz A. Relationship between intraoperative hypotension, defined by either reduction from baseline or absolute thresholds, and acute kidney and myocardial injury after noncardiac surgery: a retrospective cohort analysis. Anesthesiology. 2017;126(1):47–65. https://doi.org/10.1097/ALN.0000000000001432.CrossRefPubMed Salmasi V, Maheshwari K, Yang D, Mascha EJ, Singh A, Sessler DI, Kurz A. Relationship between intraoperative hypotension, defined by either reduction from baseline or absolute thresholds, and acute kidney and myocardial injury after noncardiac surgery: a retrospective cohort analysis. Anesthesiology. 2017;126(1):47–65. https://​doi.​org/​10.​1097/​ALN.​0000000000001432​.CrossRefPubMed
8.
go back to reference Wolfsthal SD. Is blood pressure control necessary before surgery? Med Clin North Am. 1993;77(2):349–63.CrossRefPubMed Wolfsthal SD. Is blood pressure control necessary before surgery? Med Clin North Am. 1993;77(2):349–63.CrossRefPubMed
Metadata
Title
Error-checking intraoperative arterial line blood pressures
Authors
Charles Huanghong Du
David Glick
Avery Tung
Publication date
01-06-2019
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 3/2019
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-018-0167-7

Other articles of this Issue 3/2019

Journal of Clinical Monitoring and Computing 3/2019 Go to the issue