Typical patterns of expiratory flow and carbon dioxide in mechanically ventilated patients with spontaneous breathing

Authors: S. E. Rees, S. Larraza, N. Dey, S. Spadaro, J. B. Brohus, R. W. Winding, C. A. Volta, D. S. Karbing

Published in: Journal of Clinical Monitoring and Computing | Issue 4/2017

Login to get access

Abstract

Incomplete expiration of tidal volume can lead to dynamic hyperinflation and auto-PEEP. Methods are available for assessing these, but are not appropriate for patients with respiratory muscle activity, as occurs in pressure support. Information may exist in expiratory flow and carbon dioxide measurements, which, when taken together, may help characterize dynamic hyperinflation. This paper postulates such patterns and investigates whether these can be seen systematically in data. Two variables are proposed summarizing the number of incomplete expirations quantified as a lack of return to zero flow in expiration (IncExp), and the end tidal CO2 variability (varetCO2), over 20 breaths. Using these variables, three patterns of ventilation are postulated: (a) few incomplete expirations (IncExp < 2) and small varetCO2; (b) a variable number of incomplete expirations (2 ≤ IncExp ≤ 18) and large varetCO2; and (c) a large number of incomplete expirations (IncExp > 18) and small varetCO2. IncExp and varetCO2 were calculated from data describing respiratory flow and CO2 signals in 11 patients mechanically ventilated at 5 levels of pressure support. Data analysis showed that the three patterns presented systematically in the data, with periods of IncExp < 2 or IncExp > 18 having significantly lower variability in end-tidal CO2 than periods with 2 ≤ IncExp ≤ 18 (p < 0.05). It was also shown that sudden change in IncExp from either IncExp < 2 or IncExp > 18 to 2 ≤ IncExp ≤ 18 results in significant, rapid, change in the variability of end-tidal CO2 p < 0.05. This study illustrates that systematic patterns of expiratory flow and end-tidal CO2 are present in patients in supported mechanical ventilation, and that changes between these patterns can be identified. Further studies are required to see if these patterns characterize dynamic hyperinflation. If so, then their combination may provide a useful addition to understanding the patient at the bedside.
Literature
1.
go back to reference Laghi F, Goyal A. Auto-PEEP in respiratory failure. Minerva Anestesiol. 2012;78:201–21.PubMed Laghi F, Goyal A. Auto-PEEP in respiratory failure. Minerva Anestesiol. 2012;78:201–21.PubMed
2.
go back to reference Blanch L, Bernabé F, Lucangelo U. Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic inflation in mechanically ventilated patients. Respir Care. 2005;50:110–24.PubMed Blanch L, Bernabé F, Lucangelo U. Measurement of air trapping, intrinsic positive end-expiratory pressure, and dynamic inflation in mechanically ventilated patients. Respir Care. 2005;50:110–24.PubMed
3.
go back to reference Marini JM. Dynamic hyperinflation and auto-positive end-expiratory pressure: lessons learned over 30 years. Am J Respir Crit Care Med. 2011;184:756–62.CrossRefPubMed Marini JM. Dynamic hyperinflation and auto-positive end-expiratory pressure: lessons learned over 30 years. Am J Respir Crit Care Med. 2011;184:756–62.CrossRefPubMed
4.
go back to reference Dhand R. Ventilator graphics and respiratory mechanics in the patient with obstructive lung disease. Respir Care. 2005;50(2):246–61.PubMed Dhand R. Ventilator graphics and respiratory mechanics in the patient with obstructive lung disease. Respir Care. 2005;50(2):246–61.PubMed
6.
go back to reference Lourens MS, van den Berg B, Aerts JGJV, Verbraak AFM, Hoogsteden HC, Bogaard JM. Expiratory time constants in mechanically ventilated patients with and without COPD. Intensive Care Med. 2000;26:1612–8.CrossRefPubMed Lourens MS, van den Berg B, Aerts JGJV, Verbraak AFM, Hoogsteden HC, Bogaard JM. Expiratory time constants in mechanically ventilated patients with and without COPD. Intensive Care Med. 2000;26:1612–8.CrossRefPubMed
7.
go back to reference Larraza S, Dey N, Karbing DS, Jensen JB, Nygaard M, Winding R, Rees SE. A mathematical model approach quantifying patients’ response to changes in mechanical ventilation: evaluation in pressure support. J Crit Care. 2015;30(5):1008–15.CrossRefPubMed Larraza S, Dey N, Karbing DS, Jensen JB, Nygaard M, Winding R, Rees SE. A mathematical model approach quantifying patients’ response to changes in mechanical ventilation: evaluation in pressure support. J Crit Care. 2015;30(5):1008–15.CrossRefPubMed
8.
go back to reference Deden K. Ventilation modes in intensive care. Lübeck: DrägerwerkAG & Co.; 2010. Deden K. Ventilation modes in intensive care. Lübeck: DrägerwerkAG & Co.; 2010.
9.
go back to reference Marangoni E, Alvisi V, Ragazzi R, Mojoli F, Alvisi R, Caramori G, Astolfi L, Volta CA. Respiratory mechanics at different PEEP levels during general anesthesia in the elderly: a pilot study. Minerva Anestesiol. 2012;78:1205–14.PubMed Marangoni E, Alvisi V, Ragazzi R, Mojoli F, Alvisi R, Caramori G, Astolfi L, Volta CA. Respiratory mechanics at different PEEP levels during general anesthesia in the elderly: a pilot study. Minerva Anestesiol. 2012;78:1205–14.PubMed
10.
go back to reference Galia F, Brimioulle S, Bonnier F, Vandenbergen N, Dojat M, Vincent J-L, Brochard LJ. Use of maximal end-tidal CO2 values to improve end-tidal CO2 monitoring accuracy. Respir Care. 2011;56(3):278–83.CrossRefPubMed Galia F, Brimioulle S, Bonnier F, Vandenbergen N, Dojat M, Vincent J-L, Brochard LJ. Use of maximal end-tidal CO2 values to improve end-tidal CO2 monitoring accuracy. Respir Care. 2011;56(3):278–83.CrossRefPubMed
11.
go back to reference Rossi A, Ganassini A, Polese G, Grassi V. Pulmonary hyperinflation and ventilator-dependent patients. Eur Respir J. 1997;10(7):1663–74.CrossRefPubMed Rossi A, Ganassini A, Polese G, Grassi V. Pulmonary hyperinflation and ventilator-dependent patients. Eur Respir J. 1997;10(7):1663–74.CrossRefPubMed
12.
go back to reference Bernasconi M, Ploysongsang Y, Gottfried SB, Milic-Emili J, Rossi A. Respiratory compliance and resistance in mechanically ventilated patients with acute respiratory failure. Intensive Care Med. 1988;14(5):547–53.CrossRefPubMed Bernasconi M, Ploysongsang Y, Gottfried SB, Milic-Emili J, Rossi A. Respiratory compliance and resistance in mechanically ventilated patients with acute respiratory failure. Intensive Care Med. 1988;14(5):547–53.CrossRefPubMed
13.
go back to reference Perel A, Segal E. Systolic pressure variation—a way to recognize dynamic hyperinflation. Br J Anaesth. 1996;76:168–9.CrossRefPubMed Perel A, Segal E. Systolic pressure variation—a way to recognize dynamic hyperinflation. Br J Anaesth. 1996;76:168–9.CrossRefPubMed
14.
go back to reference Hartert TV, Wheeler AP, Sheller JR. Use of pulse oximetry to recognize severity of airflow obstruction in obstructive airway disease. Chest. 1999;115:475–81.CrossRefPubMed Hartert TV, Wheeler AP, Sheller JR. Use of pulse oximetry to recognize severity of airflow obstruction in obstructive airway disease. Chest. 1999;115:475–81.CrossRefPubMed
15.
go back to reference Mancebo J, Albaladejo P, Touchard D, Bak E, Subirana M, Lemaire F, Harf A, Brochard L. Airway occlusion pressure to titrate positive end-expiratory pressure in patients with dynamic hyperinflation. Anesthesiology. 2000;93(1):81–90.CrossRefPubMed Mancebo J, Albaladejo P, Touchard D, Bak E, Subirana M, Lemaire F, Harf A, Brochard L. Airway occlusion pressure to titrate positive end-expiratory pressure in patients with dynamic hyperinflation. Anesthesiology. 2000;93(1):81–90.CrossRefPubMed
16.
go back to reference Stenz RI, Grenier B, Thompson JE, Arnold JH. Single-breath CO2 analysis as a predictor of lung volume in a healthy animal model during controlled ventilation. Crit Care Med. 1998;26(8):1409–13.CrossRefPubMed Stenz RI, Grenier B, Thompson JE, Arnold JH. Single-breath CO2 analysis as a predictor of lung volume in a healthy animal model during controlled ventilation. Crit Care Med. 1998;26(8):1409–13.CrossRefPubMed
17.
go back to reference Arnold JH, Stenz RI, Grenier B, Thompson JE. Single-breath CO2 analysis as a predictor of lung volume change in a model of acute lung injury. Crit Care Med. 2000;28(3):760–4.CrossRefPubMed Arnold JH, Stenz RI, Grenier B, Thompson JE. Single-breath CO2 analysis as a predictor of lung volume change in a model of acute lung injury. Crit Care Med. 2000;28(3):760–4.CrossRefPubMed
Metadata
Title
Typical patterns of expiratory flow and carbon dioxide in mechanically ventilated patients with spontaneous breathing
Authors
S. E. Rees
S. Larraza
N. Dey
S. Spadaro
J. B. Brohus
R. W. Winding
C. A. Volta
D. S. Karbing
Publication date
01-08-2017
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 4/2017
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-016-9903-z

Other articles of this Issue 4/2017

Journal of Clinical Monitoring and Computing 4/2017 Go to the issue