Abstract

To evaluate the utility of ultrasound for detection of the difficult intubation in a preoperative setting. PubMed, Ovid, CINAHL Plus Full Text, and Google Scholar searches using [“difficult airway” OR “difficult intubation” OR “difficult laryngoscopy” OR “difficult ventilation”] AND [ultrasonography OR sonography OR ultrasound] without date limitations. Abstracts without publications, case reports, letters, textbooks, unrelated topics, or foreign language articles were excluded. Ancestry references were included from the reviewed articles. Two reviewers independently performed the query. Each study was reviewed using the STARD checklist to assess blinding, incomplete data reporting, subject attrition, and selection of appropriate statistical tests. Ten studies were included. All used convenience sampling of adult subjects requiring direct laryngoscopy in elective surgical settings. One study is retrospective and nine are prospective observational. Populations included non-obese, obese, pregnant, and thyroidectomy patients in the United States, Turkey, Israel, Canada, Portugal, and China. Airway locations scanned are variable using different protocols and patient positioning. The outcome variable is uniformly the Cormack–Lehane Grade. 114 of the 681 total subjects had difficult laryngoscopies. Significance for sonographic prediction of difficult laryngoscopy occurred at three locations: hyomental distance [52.6 ± 5.8 mm (p < 0.01)], anterior tissue at the hyoid bone [16.9 mm (95 % CI 11.9–21.9) and 15.9 ± 2.7 mm (p < 0.0001)], and the thyrohyoid membrane [34.7 mm (95 % CI 28.8–40.7) and 23.9 ± 3.4 mm (p < 0.0001) and 28.25 ± 4.43 mm (p < 0.001)]. The vocal cords and sternal notch levels have conflicting significance. Limitations include the heterogeneous populations and lack of standard scanning protocols.
Literature
1.
go back to reference Cook TM, MacDougall-Davis SR. Complications and failure of airway management. Br J Anaesth. 2012;109(suppl 1):i68–85.CrossRefPubMed Cook TM, MacDougall-Davis SR. Complications and failure of airway management. Br J Anaesth. 2012;109(suppl 1):i68–85.CrossRefPubMed
2.
go back to reference Rose DK, Cohen MM. The incidence of airway problems depends on the definition used. Can J Anaesth. 1996;43(1):30–4.CrossRefPubMed Rose DK, Cohen MM. The incidence of airway problems depends on the definition used. Can J Anaesth. 1996;43(1):30–4.CrossRefPubMed
3.
go back to reference Apfelbaum JL, Hagberg CA, Caplan RA, et al. Practice guidelines for management of the difficult airway: an updated report by the american society of anesthesiologists task force on management of the difficult airway. J Am Soc Anesthesiol. 2013;118(2):251–70.CrossRef Apfelbaum JL, Hagberg CA, Caplan RA, et al. Practice guidelines for management of the difficult airway: an updated report by the american society of anesthesiologists task force on management of the difficult airway. J Am Soc Anesthesiol. 2013;118(2):251–70.CrossRef
4.
go back to reference Lee A, Fan LT, Gin T, Karmakar MK, Kee WDN. A systematic review (meta-analysis) of the accuracy of the Mallampati tests to predict the difficult airway. Anesth Analg. 2006;102(6):1867–78.CrossRefPubMed Lee A, Fan LT, Gin T, Karmakar MK, Kee WDN. A systematic review (meta-analysis) of the accuracy of the Mallampati tests to predict the difficult airway. Anesth Analg. 2006;102(6):1867–78.CrossRefPubMed
5.
go back to reference Lundstrøm LH, Møller AM, Rosenstock C, Astrup G, Wetterslev J. High body mass index is a weak predictor for difficult and failed tracheal intubation: a cohort study of 91,332 consecutive patients scheduled for direct laryngoscopy registered in the Danish anesthesia database. J Am Soc Anesthesiol. 2009;110(2):266–74. Lundstrøm LH, Møller AM, Rosenstock C, Astrup G, Wetterslev J. High body mass index is a weak predictor for difficult and failed tracheal intubation: a cohort study of 91,332 consecutive patients scheduled for direct laryngoscopy registered in the Danish anesthesia database. J Am Soc Anesthesiol. 2009;110(2):266–74.
6.
go back to reference Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia. 1984;39(11):1105–11.CrossRefPubMed Cormack RS, Lehane J. Difficult tracheal intubation in obstetrics. Anaesthesia. 1984;39(11):1105–11.CrossRefPubMed
7.
go back to reference Adnet F, Racine SX, Borron SW, et al. A survey of tracheal intubation difficulty in the operating room: a prospective observational study. Acta Anaesthesiol Scand. 2001;45(3):327–32.CrossRefPubMed Adnet F, Racine SX, Borron SW, et al. A survey of tracheal intubation difficulty in the operating room: a prospective observational study. Acta Anaesthesiol Scand. 2001;45(3):327–32.CrossRefPubMed
8.
9.
go back to reference Law JA, Broemling N, Cooper RM, et al. The difficult airway with recommendations for management—part 1: difficult tracheal intubation encountered in an unconscious/induced patient. Can J Anesth Can Anesth. 2013;60(11):1089–118.CrossRef Law JA, Broemling N, Cooper RM, et al. The difficult airway with recommendations for management—part 1: difficult tracheal intubation encountered in an unconscious/induced patient. Can J Anesth Can Anesth. 2013;60(11):1089–118.CrossRef
10.
go back to reference Law JA, Broemling N, Cooper RM, et al. The difficult airway with recommendations for management—part 2: the anticipated difficult airway. Can J Anesth Can Anesth. 2013;60(11):1119–38.CrossRef Law JA, Broemling N, Cooper RM, et al. The difficult airway with recommendations for management—part 2: the anticipated difficult airway. Can J Anesth Can Anesth. 2013;60(11):1119–38.CrossRef
11.
go back to reference Shiga T, Wajima Z, Inoue T, Sakamoto A. Predicting difficult intubation in apparently normal patients: a meta-analysis of bedside screening test performance. J Am Soc Anesthesiol. 2005;103(2):429–37.CrossRef Shiga T, Wajima Z, Inoue T, Sakamoto A. Predicting difficult intubation in apparently normal patients: a meta-analysis of bedside screening test performance. J Am Soc Anesthesiol. 2005;103(2):429–37.CrossRef
12.
go back to reference Bannister F, Macbeth R. Direct laryngoscopy and tracheal intubation. The Lancet. 1944;244(6325):651–4.CrossRef Bannister F, Macbeth R. Direct laryngoscopy and tracheal intubation. The Lancet. 1944;244(6325):651–4.CrossRef
13.
go back to reference Yentis SM. Predicting difficult intubation—Worthwhile exercise or pointless ritual? Anaesthesia. 2002;57(2):105.CrossRefPubMed Yentis SM. Predicting difficult intubation—Worthwhile exercise or pointless ritual? Anaesthesia. 2002;57(2):105.CrossRefPubMed
14.
go back to reference Lundstrøm LH, Vester-Andersen M, Møller AM, Charuluxananan S, L’hermite J, Wetterslev J. Poor prognostic value of the modified Mallampati score: a meta-analysis involving 177,088 patients. Br J Anaesth. 2011;107(5):659–67.CrossRefPubMed Lundstrøm LH, Vester-Andersen M, Møller AM, Charuluxananan S, L’hermite J, Wetterslev J. Poor prognostic value of the modified Mallampati score: a meta-analysis involving 177,088 patients. Br J Anaesth. 2011;107(5):659–67.CrossRefPubMed
15.
16.
go back to reference Baker PA, Depuydt A, Thompson JMD. Thyromental distance measurement—fingers don’t rule. Anaesthesia. 2009;64(8):878–82.CrossRefPubMed Baker PA, Depuydt A, Thompson JMD. Thyromental distance measurement—fingers don’t rule. Anaesthesia. 2009;64(8):878–82.CrossRefPubMed
17.
go back to reference Langeron O, Birenbaum A, Le Saché F, Raux M. Airway management in obese patient. Minerva Anestesiol. 2014;80(3):382–92.PubMed Langeron O, Birenbaum A, Le Saché F, Raux M. Airway management in obese patient. Minerva Anestesiol. 2014;80(3):382–92.PubMed
18.
go back to reference Teoh WH, Kristensen MS. Utility of ultrasound in airway management. Trends Anaesth Crit Care. 2014;4(4):84–90.CrossRef Teoh WH, Kristensen MS. Utility of ultrasound in airway management. Trends Anaesth Crit Care. 2014;4(4):84–90.CrossRef
20.
go back to reference Prasad A, Yu E, Wong DT, Karkhanis R, Gullane P, Chan VW. Comparison of sonography and computed tomography as imaging tools for assessment of airway structures. J Ultrasound Med. 2011;30(7):965–72.CrossRefPubMed Prasad A, Yu E, Wong DT, Karkhanis R, Gullane P, Chan VW. Comparison of sonography and computed tomography as imaging tools for assessment of airway structures. J Ultrasound Med. 2011;30(7):965–72.CrossRefPubMed
21.
go back to reference Kristensen MS, Teoh WH, Graumann O, Laursen CB. Ultrasonography for clinical decision-making and intervention in airway management: from the mouth to the lungs and pleurae. Insights Imaging. 2014;5(2):253–79.CrossRefPubMedPubMedCentral Kristensen MS, Teoh WH, Graumann O, Laursen CB. Ultrasonography for clinical decision-making and intervention in airway management: from the mouth to the lungs and pleurae. Insights Imaging. 2014;5(2):253–79.CrossRefPubMedPubMedCentral
22.
go back to reference Lakhal K, Delplace X, Cottier J-P, et al. The feasibility of ultrasound to assess subglottic diameter. Anesth Analg. 2007;104(3):611–4.CrossRefPubMed Lakhal K, Delplace X, Cottier J-P, et al. The feasibility of ultrasound to assess subglottic diameter. Anesth Analg. 2007;104(3):611–4.CrossRefPubMed
23.
go back to reference Wojtczak J, Bonadonna P. Pocket mobile smartphone system for the point-of-care submandibular ultrasonography. Am J Emerg Med. 2013;31(3):573–7.CrossRefPubMed Wojtczak J, Bonadonna P. Pocket mobile smartphone system for the point-of-care submandibular ultrasonography. Am J Emerg Med. 2013;31(3):573–7.CrossRefPubMed
24.
go back to reference Chou EH, Dickman E, Tsou P-Y, et al. Ultrasonography for confirmation of endotracheal tube placement: a systematic review and meta-analysis. Resuscitation. 2015;90:97–103.CrossRefPubMed Chou EH, Dickman E, Tsou P-Y, et al. Ultrasonography for confirmation of endotracheal tube placement: a systematic review and meta-analysis. Resuscitation. 2015;90:97–103.CrossRefPubMed
25.
go back to reference Deshpande R, Akhtar S, Haddadin AS. Utility of ultrasound in the ICU. Curr Opin Anesthesiol. 2014;27(2):123–32.CrossRef Deshpande R, Akhtar S, Haddadin AS. Utility of ultrasound in the ICU. Curr Opin Anesthesiol. 2014;27(2):123–32.CrossRef
26.
go back to reference Kristensen MS. Ultrasonography in the management of the airway. Acta Anaesthesiol Scand. 2011;55(10):1155–73.CrossRefPubMed Kristensen MS. Ultrasonography in the management of the airway. Acta Anaesthesiol Scand. 2011;55(10):1155–73.CrossRefPubMed
27.
go back to reference Terkawi AS, Karakitsos D, Elbarbary M, Blaivas M, Durieux ME. Ultrasound for the anesthesiologists: present and future. Sci World J. 2013;2013:1–15. Terkawi AS, Karakitsos D, Elbarbary M, Blaivas M, Durieux ME. Ultrasound for the anesthesiologists: present and future. Sci World J. 2013;2013:1–15.
28.
go back to reference Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med. 2009;151(4):264–9.CrossRefPubMed Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. Ann Intern Med. 2009;151(4):264–9.CrossRefPubMed
29.
go back to reference Bossuyt PM, Reitsma JB, Bruns DE, et al. Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative. Clin Chem Lab Med. 2003;41(1):68–73.CrossRefPubMed Bossuyt PM, Reitsma JB, Bruns DE, et al. Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative. Clin Chem Lab Med. 2003;41(1):68–73.CrossRefPubMed
30.
go back to reference Carlson M, Protsman L, Tomaka J. Graphic organizers can facilitate selection of statistical tests Part 1: analysis of group differences. J Phys Ther Educ. 2005;19(2):57–65. Carlson M, Protsman L, Tomaka J. Graphic organizers can facilitate selection of statistical tests Part 1: analysis of group differences. J Phys Ther Educ. 2005;19(2):57–65.
31.
go back to reference Protsman L, Carlson M. Graphic organizers can facilitate selection of statistical tests: part 2—correlation and regression analysis. J Phys Ther Educ. 2008;22(2):36–41. Protsman L, Carlson M. Graphic organizers can facilitate selection of statistical tests: part 2—correlation and regression analysis. J Phys Ther Educ. 2008;22(2):36–41.
32.
go back to reference Wojtczak JA. Submandibular sonography assessment of hyomental distances and ratio, tongue size, and floor of the mouth musculature using portable sonography. J Ultrasound Med. 2012;31(4):523–8.CrossRefPubMed Wojtczak JA. Submandibular sonography assessment of hyomental distances and ratio, tongue size, and floor of the mouth musculature using portable sonography. J Ultrasound Med. 2012;31(4):523–8.CrossRefPubMed
34.
go back to reference Gupta D, Srirajakalidindi A, Ittiara B, Apple L, Toshniwal G, Haber H. Ultrasonographic modification of Cormack Lehane classification for pre-anesthetic airway assessment. Middle East J Anesth. 2012;21:835–42. Gupta D, Srirajakalidindi A, Ittiara B, Apple L, Toshniwal G, Haber H. Ultrasonographic modification of Cormack Lehane classification for pre-anesthetic airway assessment. Middle East J Anesth. 2012;21:835–42.
36.
go back to reference Komatsu R, Sengupta P, Wadhwa A, Akça O. Ultrasound quantification of anterior soft tissue thickness fails to predict difficult laryngoscopy in obese patients. Anaesth Intensive Care. 2007;35(1):32.PubMed Komatsu R, Sengupta P, Wadhwa A, Akça O. Ultrasound quantification of anterior soft tissue thickness fails to predict difficult laryngoscopy in obese patients. Anaesth Intensive Care. 2007;35(1):32.PubMed
37.
go back to reference Wu J, Dong J, Ding Y, Zheng J. Role of anterior neck soft tissue quantifications by ultrasound in predicting difficult laryngoscopy. Med Sci Monit Int Med J Exp Clin Res. 2014;20:2343. Wu J, Dong J, Ding Y, Zheng J. Role of anterior neck soft tissue quantifications by ultrasound in predicting difficult laryngoscopy. Med Sci Monit Int Med J Exp Clin Res. 2014;20:2343.
38.
go back to reference Ezri T, Gewürtz G, Sessler DI, et al. Prediction of difficult laryngoscopy in obese patients by ultrasound quantification of anterior neck soft tissue*. Anaesthesia. 2003;58(11):1111–4.CrossRefPubMedPubMedCentral Ezri T, Gewürtz G, Sessler DI, et al. Prediction of difficult laryngoscopy in obese patients by ultrasound quantification of anterior neck soft tissue*. Anaesthesia. 2003;58(11):1111–4.CrossRefPubMedPubMedCentral
39.
go back to reference Meco BC, Alanoglu Z, Yilmaz AA, et al. Does ultrasonographic volume of the thyroid gland correlate with difficult intubation? An observational study. Braz J Anesthesiol Engl Ed. 2015;65(3):230–4. doi:10.1016/j.bjane.2014.06.004. Meco BC, Alanoglu Z, Yilmaz AA, et al. Does ultrasonographic volume of the thyroid gland correlate with difficult intubation? An observational study. Braz J Anesthesiol Engl Ed. 2015;65(3):230–4. doi:10.​1016/​j.​bjane.​2014.​06.​004.
40.
go back to reference Aydogmus M, Erkalp K, Sinikoglu SN, Usta TA, Ulger GO, Alagol A. Is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: a prospective comparative study. Pak J Med Sci. 2014;. doi:10.12669/pjms.301.3972. Aydogmus M, Erkalp K, Sinikoglu SN, Usta TA, Ulger GO, Alagol A. Is ultrasonic investigation of transverse tracheal air shadow diameter reasonable for evaluation of difficult airway in pregnant women: a prospective comparative study. Pak J Med Sci. 2014;. doi:10.​12669/​pjms.​301.​3972.
41.
go back to reference Pinto J, Cordeiro L, Pereira C, Gama R, Fernandes HL, Assunção J. Predicting difficult laryngoscopy using ultrasound measurement of distance from skin to epiglottis. J Crit Care. 2016;33:26–31.CrossRefPubMed Pinto J, Cordeiro L, Pereira C, Gama R, Fernandes HL, Assunção J. Predicting difficult laryngoscopy using ultrasound measurement of distance from skin to epiglottis. J Crit Care. 2016;33:26–31.CrossRefPubMed
42.
go back to reference Naguib M, Scamman FL, O’Sullivan C, et al. Predictive performance of three multivariate difficult tracheal intubation models: a double-blind, case-controlled study. Anesth Analg. 2006;102(3):818–24.CrossRefPubMed Naguib M, Scamman FL, O’Sullivan C, et al. Predictive performance of three multivariate difficult tracheal intubation models: a double-blind, case-controlled study. Anesth Analg. 2006;102(3):818–24.CrossRefPubMed
43.
go back to reference Wang J, Thornton JC, Russell M, Burastero S, Heymsfield S, Pierson RN. Asians have lower body mass index (BMI) but higher percent body fat than do whites: comparisons of anthropometric measurements. Am J Clin Nutr. 1994;60(1):23–8.PubMed Wang J, Thornton JC, Russell M, Burastero S, Heymsfield S, Pierson RN. Asians have lower body mass index (BMI) but higher percent body fat than do whites: comparisons of anthropometric measurements. Am J Clin Nutr. 1994;60(1):23–8.PubMed
44.
go back to reference Penning L. Radioanatomy of upper airways in flexion and retroflexion of the neck. Neuroradiology. 1988;30(1):17–21.CrossRefPubMed Penning L. Radioanatomy of upper airways in flexion and retroflexion of the neck. Neuroradiology. 1988;30(1):17–21.CrossRefPubMed
45.
go back to reference Yentis SM, Lee DJH. Evaluation of an improved scoring system for the grading of direct laryngoscopy. Anaesthesia. 1998;53(11):1041–4.CrossRefPubMed Yentis SM, Lee DJH. Evaluation of an improved scoring system for the grading of direct laryngoscopy. Anaesthesia. 1998;53(11):1041–4.CrossRefPubMed
46.
go back to reference Jabalameli M, Hashemi J, Mazoochi M. The effect of different Sellick’s maneuver on laryngoscopic view and intubation time. J Res Med Sci. 2005;10(5):285–7. Jabalameli M, Hashemi J, Mazoochi M. The effect of different Sellick’s maneuver on laryngoscopic view and intubation time. J Res Med Sci. 2005;10(5):285–7.
47.
go back to reference Benumof JL, Cooper SD. Quantitative improvement in laryngoscopic view by optimal external laryngeal manipulation. J Clin Anesth. 1996;8(2):136–40.CrossRefPubMed Benumof JL, Cooper SD. Quantitative improvement in laryngoscopic view by optimal external laryngeal manipulation. J Clin Anesth. 1996;8(2):136–40.CrossRefPubMed
48.
go back to reference Mosier JM, Sakles JC, Stolz U, et al. Neuromuscular blockade improves first-attempt success for intubation in the intensive care unit. A propensity matched analysis. Ann Am Thorac Soc. 2015;12(5):734–41.CrossRefPubMed Mosier JM, Sakles JC, Stolz U, et al. Neuromuscular blockade improves first-attempt success for intubation in the intensive care unit. A propensity matched analysis. Ann Am Thorac Soc. 2015;12(5):734–41.CrossRefPubMed
Metadata
Title
Ultrasonography in the preoperative difficult airway assessment
Authors
Justin S. Fulkerson
Heather M. Moore
Tristan S. Anderson
Robert F. Lowe Jr.
Publication date
01-06-2017
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 3/2017
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-016-9888-7

Other articles of this Issue 3/2017

Journal of Clinical Monitoring and Computing 3/2017 Go to the issue