Abstract

Continuous electronic monitoring of patient respiratory status frequently includes PetCO2 (end tidal CO2), RR (respiration rate), SpO2 (arterial oxygen saturation), and PR (pulse rate). Interpreting and integrating these vital signs as numbers or waveforms is routinely done by anesthesiologists and intensivists but is challenging for clinicians in low acuity areas such as medical wards, where continuous electronic respiratory monitoring is becoming more common place. We describe a heuristic algorithm that simplifies the interpretation of these four parameters in assessing a patient’s respiratory status, the Integrated Pulmonary Index (IPI). The IPI algorithm is a mathematical model combining SpO2, RR, PR, and PetCO2 into a single value between 1 and 10 that summarizes the adequacy of ventilation and oxygenation at that point in time. The algorithm was designed using a fuzzy logic inference model to incorporate expert clinical opinions. The algorithm was verified by comparison to experts’ scoring of clinical scenarios. The validity of the index was tested in a retrospective analysis of continuous SpO2, RR, PR, and PetCO2 readings obtained from 523 patients in a variety of clinical settings. IPI correlated well with expert interpretation of the continuous respiratory data (R = 0.83, p <<< 0.001), with agreement of −0.5 ± 1.4. Receiver operating curves analysis resulted in high levels of sensitivity (ranging from 0.83 to 1.00), and corresponding specificity (ranging from 0.96 to 0.74), based on IPI thresholds 3−6. The IPI reliably interpreted the respiratory status of patients in multiple areas of care using off-line continuous respiratory data. Further prospective studies are required to evaluate IPI in real time in clinical settings.
Literature
1.
go back to reference Overdyk FJ, Carter R, Maddox RR, et al. Continuous oximetry/capnometry monitoring reveals frequent desaturation and bradypnea during patient-controlled analgesia. Anesth Analg. 2007;105:412–8.CrossRefPubMed Overdyk FJ, Carter R, Maddox RR, et al. Continuous oximetry/capnometry monitoring reveals frequent desaturation and bradypnea during patient-controlled analgesia. Anesth Analg. 2007;105:412–8.CrossRefPubMed
5.
go back to reference Jarzyna D, Jungquist CR, Pasero C, et al. American Society for Pain Management Nursing guidelines on monitoring of opioid-induced sedation and respiratory depression. Pain Manag Nurs. 2011;12(3):118–45.CrossRefPubMed Jarzyna D, Jungquist CR, Pasero C, et al. American Society for Pain Management Nursing guidelines on monitoring of opioid-induced sedation and respiratory depression. Pain Manag Nurs. 2011;12(3):118–45.CrossRefPubMed
7.
go back to reference ASA Standards for Basic Anesthetic Monitoring Approved by the ASA House of Delegates on October 21, 1986, and last amended on October 20, 2010 with an effective date of July 1, 2011. ASA Standards for Basic Anesthetic Monitoring Approved by the ASA House of Delegates on October 21, 1986, and last amended on October 20, 2010 with an effective date of July 1, 2011.
8.
go back to reference Norris PR, Dawant BM. Knowledge-based systems for intelligent patient monitoring and management in critical care environments. In: Bronzino JD, editor. The biomedical engineering handbook, Chap 186. 2nd ed. Boca Raton: CRC Press; 1999. Norris PR, Dawant BM. Knowledge-based systems for intelligent patient monitoring and management in critical care environments. In: Bronzino JD, editor. The biomedical engineering handbook, Chap 186. 2nd ed. Boca Raton: CRC Press; 1999.
9.
go back to reference Faust D. The limits of scientific reasoning. Minneapolis: University of Minnesota Press; 1984. Faust D. The limits of scientific reasoning. Minneapolis: University of Minnesota Press; 1984.
10.
go back to reference McCarter T, Shaik Z, Scarfo K, Thompson LJ. Capnography monitoring enhances safety of postoperative patient-controlled analgesia. Am Health Drug Benefits. 2008;1(5):28–35.PubMedPubMedCentral McCarter T, Shaik Z, Scarfo K, Thompson LJ. Capnography monitoring enhances safety of postoperative patient-controlled analgesia. Am Health Drug Benefits. 2008;1(5):28–35.PubMedPubMedCentral
11.
go back to reference Tarassenko L, Hann A, Young D. Integrated monitoring and analysis for early warning of patient deterioration. Br J Anaesth. 2006;97(1):64–8.CrossRefPubMed Tarassenko L, Hann A, Young D. Integrated monitoring and analysis for early warning of patient deterioration. Br J Anaesth. 2006;97(1):64–8.CrossRefPubMed
12.
go back to reference Tsoukalas LH, Uhrig RE. Fuzzy and neural approaches in engineering. London: Wiley; 1997. ISBN 0-471-16003-2. Tsoukalas LH, Uhrig RE. Fuzzy and neural approaches in engineering. London: Wiley; 1997. ISBN 0-471-16003-2.
13.
go back to reference Dieckmann R, Brownstein D, Gausche-Hill M, editors. Pediatric education for prehospital professionals. Sudbury: Jones & Bartlett, American Academy of Pediatrics; 2000. p. 43–5. Dieckmann R, Brownstein D, Gausche-Hill M, editors. Pediatric education for prehospital professionals. Sudbury: Jones & Bartlett, American Academy of Pediatrics; 2000. p. 43–5.
14.
go back to reference Behrman R, Kliegman R, Jenson H, editors: Nelson textbook of pediatrics. 17th ed. Elsevier Health; 2003. p. 280–281. Behrman R, Kliegman R, Jenson H, editors: Nelson textbook of pediatrics. 17th ed. Elsevier Health; 2003. p. 280–281.
15.
go back to reference Bland JM, Altman DG. Agreement between methods with multiple observations. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed Bland JM, Altman DG. Agreement between methods with multiple observations. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed
16.
go back to reference Taenzer AH, Pyke J, Herrick MD, Dodds TM, McGrath SP. A comparison of oxygen saturation data in inpatients with low oxygen saturation using automated continuous monitoring and intermittent manual data charting. Anesth Analg. 2014;118:326–31.CrossRefPubMed Taenzer AH, Pyke J, Herrick MD, Dodds TM, McGrath SP. A comparison of oxygen saturation data in inpatients with low oxygen saturation using automated continuous monitoring and intermittent manual data charting. Anesth Analg. 2014;118:326–31.CrossRefPubMed
17.
go back to reference American Academy of Pediatrics. National Institutes of Health consensus development conference on infantile apnea and home monitoring, Sept 29 to Oct 1, 1986. Pediatrics. 1987;79:292–299. American Academy of Pediatrics. National Institutes of Health consensus development conference on infantile apnea and home monitoring, Sept 29 to Oct 1, 1986. Pediatrics. 1987;79:292–299.
18.
go back to reference Lightdale JR, Goldmann DA, Feldman HA, Newburg AR, DiNardo JA, Fox VL. Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial. Pediatrics. 2006;117(6):e1170–8.CrossRefPubMed Lightdale JR, Goldmann DA, Feldman HA, Newburg AR, DiNardo JA, Fox VL. Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial. Pediatrics. 2006;117(6):e1170–8.CrossRefPubMed
19.
go back to reference Vargo JJ, Zuccaro G Jr, Dumot JA, et al. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. Gastrointest Endosc. 2002;55(7):826–31.CrossRefPubMed Vargo JJ, Zuccaro G Jr, Dumot JA, et al. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. Gastrointest Endosc. 2002;55(7):826–31.CrossRefPubMed
20.
go back to reference Overdyk F. Improving outcomes in in med-surg patients with opioid induced respiratory depression. Am Nurse Today. 2011;6(11):26–31. Overdyk F. Improving outcomes in in med-surg patients with opioid induced respiratory depression. Am Nurse Today. 2011;6(11):26–31.
21.
go back to reference Berkenstadt H, Ben-Menachem E, Herman A, Dach R. An evaluation of the Integrated Pulmonary Index (IPI) for the detection of respiratory events in sedated patients undergoing colonoscopy. J Clin Monit Comput. 2012;26:177–81.CrossRefPubMed Berkenstadt H, Ben-Menachem E, Herman A, Dach R. An evaluation of the Integrated Pulmonary Index (IPI) for the detection of respiratory events in sedated patients undergoing colonoscopy. J Clin Monit Comput. 2012;26:177–81.CrossRefPubMed
Metadata
Title
Smart respiratory monitoring: clinical development and validation of the IPI™ (Integrated Pulmonary Index) algorithm
Authors
M. Ronen
R. Weissbrod
F. J. Overdyk
S. Ajizian
Publication date
01-04-2017
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2017
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-016-9851-7

Other articles of this Issue 2/2017

Journal of Clinical Monitoring and Computing 2/2017 Go to the issue