Published in: Journal of Clinical Monitoring and Computing 6/2016

Open Access 01-12-2016 | Original Research

Estimation of extravascular lung water using the transpulmonary ultrasound dilution (TPUD) method: a validation study in neonatal lambs

Authors: S. L. Vrancken, A. Nusmeier, J. C. Hopman, K. D. Liem, J. G. van der Hoeven, J. Lemson, A. F. van Heijst, W. P. de Boode

Published in: Journal of Clinical Monitoring and Computing | Issue 6/2016

Login to get access

Abstract

Increased extravascular lung water (EVLW) may contribute to respiratory failure in neonates. Accurate measurement of EVLW in these patients is limited due to the lack of bedside methods. The aim of this pilot study was to investigate the reliability of the transpulmonary ultrasound dilution (TPUD) technique as a possible method for estimating EVLW in a neonatal animal model. Pulmonary edema was induced in 11 lambs by repeated surfactant lavages. In between the lavages, EVLW indexed by bodyweight was estimated by TPUD (EVLWItpud) and transpulmonary dye dilution (EVLWItpdd) (n = 22). Final EVLWItpud measurements were also compared with EVLWI estimations by gold standard post mortem gravimetry (EVLWIgrav) (n = 6). EVLWI was also measured in two additional lambs without pulmonary edema. Bland–Altman plots showed a mean bias between EVLWItpud and EVLWItpdd of −3.4 mL/kg (LOA ± 25.8 mL/kg) and between EVLWItpud and EVLWIgrav of 1.7 mL/kg (LOA ± 8.3 mL/kg). The percentage errors were 109 and 43 % respectively. The correlation between changes in EVLW measured by TPUD and TPDD was r2 = 0.22. Agreement between EVLWI measurements by TPUD and TPDD was low. Trending ability to detect changes between these two methods in EVLWI was questionable. The accuracy of EVLWItpud was good compared to the gold standard gravimetric method but the TPUD lacked precision in its current prototype. Based on these limited data, we believe that TPUD has potential for future use to estimate EVLW after adaptation of the algorithm. Larger studies are needed to support our findings.
Appendix
Available only for authorised users
Literature
1.
2.
go back to reference Zhang Z, Lu B, Ni H. Prognostic value of extravascular lung water index in critically ill patients: a systematic review of the literature. J Crit Care. 2012;27(420):e421–8. Zhang Z, Lu B, Ni H. Prognostic value of extravascular lung water index in critically ill patients: a systematic review of the literature. J Crit Care. 2012;27(420):e421–8.
3.
go back to reference Jozwiak M, Silva S, Persichini R, Anguel N, Osman D, Richard C, Teboul JL, Monnet X. Extravascular lung water is an independent prognostic factor in patients with acute respiratory distress syndrome. Crit Care Med. 2013;41:472–80.CrossRefPubMed Jozwiak M, Silva S, Persichini R, Anguel N, Osman D, Richard C, Teboul JL, Monnet X. Extravascular lung water is an independent prognostic factor in patients with acute respiratory distress syndrome. Crit Care Med. 2013;41:472–80.CrossRefPubMed
4.
go back to reference Craig TR, Duffy MJ, Shyamsundar M, McDowell C, McLaughlin B, Elborn JS, McAuley DF. Extravascular lung water indexed to predicted body weight is a novel predictor of intensive care unit mortality in patients with acute lung injury. Crit Care Med. 2010;38:114–20.CrossRefPubMed Craig TR, Duffy MJ, Shyamsundar M, McDowell C, McLaughlin B, Elborn JS, McAuley DF. Extravascular lung water indexed to predicted body weight is a novel predictor of intensive care unit mortality in patients with acute lung injury. Crit Care Med. 2010;38:114–20.CrossRefPubMed
5.
go back to reference Schiffmann H, Erdlenbruch B, Singer D, Singer S, Herting E, Hoeft A, Buhre W. Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants. J Cardiothorac Vasc Anesth. 2002;16:592–7.CrossRefPubMed Schiffmann H, Erdlenbruch B, Singer D, Singer S, Herting E, Hoeft A, Buhre W. Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants. J Cardiothorac Vasc Anesth. 2002;16:592–7.CrossRefPubMed
6.
go back to reference Kraft R, Herndon DN, Branski LK, Finnerty CC, Leonard KR, Jeschke MG. Optimized fluid management improves outcomes of pediatric burn patients. J Surg Res. 2013;181:121–8.CrossRefPubMed Kraft R, Herndon DN, Branski LK, Finnerty CC, Leonard KR, Jeschke MG. Optimized fluid management improves outcomes of pediatric burn patients. J Surg Res. 2013;181:121–8.CrossRefPubMed
7.
go back to reference Lubrano R, Cecchetti C, Elli M, Tomasello C, Guido G, Di NM, Masciangelo R, Pasotti E, Barbieri MA, Bellelli E, Pirozzi N. Prognostic value of extravascular lung water index in critically ill children with acute respiratory failure. Intensive Care Med. 2011;37:124–31.CrossRefPubMed Lubrano R, Cecchetti C, Elli M, Tomasello C, Guido G, Di NM, Masciangelo R, Pasotti E, Barbieri MA, Bellelli E, Pirozzi N. Prognostic value of extravascular lung water index in critically ill children with acute respiratory failure. Intensive Care Med. 2011;37:124–31.CrossRefPubMed
8.
go back to reference Wheeler DS, Dent CL, Manning PB, Nelson DP. Factors prolonging length of stay in the cardiac intensive care unit following the arterial switch operation. Cardiol Young. 2008;18:41–50.CrossRefPubMed Wheeler DS, Dent CL, Manning PB, Nelson DP. Factors prolonging length of stay in the cardiac intensive care unit following the arterial switch operation. Cardiol Young. 2008;18:41–50.CrossRefPubMed
9.
go back to reference Vuohelainen T, Ojala R, Virtanen A, Korhonen P, Luukkaala T, Holm P, Tammela O. Decreased free water clearance is associated with worse respiratory outcomes in premature infants. PLoS ONE. 2011;6:e16995.CrossRefPubMedPubMedCentral Vuohelainen T, Ojala R, Virtanen A, Korhonen P, Luukkaala T, Holm P, Tammela O. Decreased free water clearance is associated with worse respiratory outcomes in premature infants. PLoS ONE. 2011;6:e16995.CrossRefPubMedPubMedCentral
10.
go back to reference Collins JC, Newman JH, Wickersham NE, Vaughn WK, Snapper JR, Harris TR, Brigham KL. Relation of blood-free to blood-inclusive postmortem lung water measurements in sheep. J Appl Physiol. 1985;59:592–6.PubMed Collins JC, Newman JH, Wickersham NE, Vaughn WK, Snapper JR, Harris TR, Brigham KL. Relation of blood-free to blood-inclusive postmortem lung water measurements in sheep. J Appl Physiol. 1985;59:592–6.PubMed
11.
go back to reference Julien M, Flick MR, Hoeffel JM, Murray JF. Accurate reference measurement for postmortem lung water. J Appl Physiol. 1984;56:248–53.PubMed Julien M, Flick MR, Hoeffel JM, Murray JF. Accurate reference measurement for postmortem lung water. J Appl Physiol. 1984;56:248–53.PubMed
12.
13.
go back to reference Holcroft JW, Trunkey DD, Carpenter MA. Excessive fluid administration in resuscitating baboons from hemorrhagic shock, and an assessment of the thermodye technic for measuring extravascular lung water. Am J Surg. 1978;135:412–6.CrossRefPubMed Holcroft JW, Trunkey DD, Carpenter MA. Excessive fluid administration in resuscitating baboons from hemorrhagic shock, and an assessment of the thermodye technic for measuring extravascular lung water. Am J Surg. 1978;135:412–6.CrossRefPubMed
14.
go back to reference Maddison B, Giudici R, Calzia E, Wolff C, Hinds C, Radermacher P, Pearse RM. Extravascular lung water volume measurement by a novel lithium-thermal indicator dilution method: comparison of three techniques to post-mortem gravimetry. Intensive Care Med. 2008;34:2106–11.CrossRefPubMed Maddison B, Giudici R, Calzia E, Wolff C, Hinds C, Radermacher P, Pearse RM. Extravascular lung water volume measurement by a novel lithium-thermal indicator dilution method: comparison of three techniques to post-mortem gravimetry. Intensive Care Med. 2008;34:2106–11.CrossRefPubMed
15.
go back to reference Mihm FG, Feeley TW, Jamieson SW. Thermal dye double indicator dilution measurement of lung water in man: comparison with gravimetric measurements. Thorax. 1987;42:72–6.CrossRefPubMedPubMedCentral Mihm FG, Feeley TW, Jamieson SW. Thermal dye double indicator dilution measurement of lung water in man: comparison with gravimetric measurements. Thorax. 1987;42:72–6.CrossRefPubMedPubMedCentral
16.
go back to reference Katzenelson R, Perel A, Berkenstadt H, Preisman S, Kogan S, Sternik L, Segal E. Accuracy of transpulmonary thermodilution versus gravimetric measurement of extravascular lung water. Crit Care Med. 2004;32:1550–4.CrossRefPubMed Katzenelson R, Perel A, Berkenstadt H, Preisman S, Kogan S, Sternik L, Segal E. Accuracy of transpulmonary thermodilution versus gravimetric measurement of extravascular lung water. Crit Care Med. 2004;32:1550–4.CrossRefPubMed
17.
go back to reference Kirov MY, Kuzkov VV, Kuklin VN, Waerhaug K, Bjertnaes LJ. Extravascular lung water assessed by transpulmonary single thermodilution and postmortem gravimetry in sheep. Crit Care. 2004;8:R451–8.CrossRefPubMedPubMedCentral Kirov MY, Kuzkov VV, Kuklin VN, Waerhaug K, Bjertnaes LJ. Extravascular lung water assessed by transpulmonary single thermodilution and postmortem gravimetry in sheep. Crit Care. 2004;8:R451–8.CrossRefPubMedPubMedCentral
18.
go back to reference Rossi P, Wanecek M, Rudehill A, Konrad D, Weitzberg E, Oldner A. Comparison of a single indicator and gravimetric technique for estimation of extravascular lung water in endotoxemic pigs. Crit Care Med. 2006;34:1437–43.CrossRefPubMed Rossi P, Wanecek M, Rudehill A, Konrad D, Weitzberg E, Oldner A. Comparison of a single indicator and gravimetric technique for estimation of extravascular lung water in endotoxemic pigs. Crit Care Med. 2006;34:1437–43.CrossRefPubMed
19.
go back to reference Lindberg L, Johansson S, Perez-de-Sa V. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children. Pediatr Crit Care Med. 2014;15:139–47.CrossRefPubMed Lindberg L, Johansson S, Perez-de-Sa V. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children. Pediatr Crit Care Med. 2014;15:139–47.CrossRefPubMed
20.
go back to reference Vrancken SL, de Boode WP, Hopman JC, Singh SK, Liem KD, van Heijst AF. Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs. Br J Anaesth. 2012;108:409–16.CrossRefPubMed Vrancken SL, de Boode WP, Hopman JC, Singh SK, Liem KD, van Heijst AF. Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs. Br J Anaesth. 2012;108:409–16.CrossRefPubMed
21.
go back to reference Krivitski NM, Kislukhin VV, Thuramalla NV. Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients. Pediatr Crit Care Med. 2008;9:423–8.CrossRefPubMedPubMedCentral Krivitski NM, Kislukhin VV, Thuramalla NV. Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients. Pediatr Crit Care Med. 2008;9:423–8.CrossRefPubMedPubMedCentral
22.
go back to reference Lemson J, Eijk RJ, van der Hoeven JG. The “cross-talk phenomenon” in transpulmonary thermodilution is flow dependent. Intensive Care Med. 2006;32:1092.CrossRefPubMed Lemson J, Eijk RJ, van der Hoeven JG. The “cross-talk phenomenon” in transpulmonary thermodilution is flow dependent. Intensive Care Med. 2006;32:1092.CrossRefPubMed
23.
go back to reference Lachmann B, Robertson B, Vogel J. In vivo lung lavage as an experimental model of the respiratory distress syndrome. Acta Anaesthesiol Scand. 1980;24:231–6.CrossRefPubMed Lachmann B, Robertson B, Vogel J. In vivo lung lavage as an experimental model of the respiratory distress syndrome. Acta Anaesthesiol Scand. 1980;24:231–6.CrossRefPubMed
24.
go back to reference Wang HM, Bodenstein M, Markstaller K. Overview of the pathology of three widely used animal models of acute lung injury. Eur Surg Res. 2008;40:305–16.CrossRefPubMed Wang HM, Bodenstein M, Markstaller K. Overview of the pathology of three widely used animal models of acute lung injury. Eur Surg Res. 2008;40:305–16.CrossRefPubMed
25.
go back to reference Moser M, Kenner T. Blood flow and blood volume determinations in aorta and in coronary circulation by density dilution. Basic Res Cardiol. 1988;83:577–89.CrossRefPubMed Moser M, Kenner T. Blood flow and blood volume determinations in aorta and in coronary circulation by density dilution. Basic Res Cardiol. 1988;83:577–89.CrossRefPubMed
26.
go back to reference Reuter DA, Huang C, Edrich T, Shernan SK, Eltzschig HK. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth Analg. 2010;110:799–811.CrossRefPubMed Reuter DA, Huang C, Edrich T, Shernan SK, Eltzschig HK. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth Analg. 2010;110:799–811.CrossRefPubMed
27.
go back to reference Sakka SG, Ruhl CC, Pfeiffer UJ, Beale R, McLuckie A, Reinhart K, Meier-Hellmann A. Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med. 2000;26:180–7.CrossRefPubMed Sakka SG, Ruhl CC, Pfeiffer UJ, Beale R, McLuckie A, Reinhart K, Meier-Hellmann A. Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med. 2000;26:180–7.CrossRefPubMed
28.
go back to reference Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–10.CrossRefPubMed Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307–10.CrossRefPubMed
29.
go back to reference Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed
30.
go back to reference Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed
31.
go back to reference Michard F. Bedside assessment of extravascular lung water by dilution methods: temptations and pitfalls. Crit Care Med. 2007;35:1186–92.CrossRefPubMed Michard F. Bedside assessment of extravascular lung water by dilution methods: temptations and pitfalls. Crit Care Med. 2007;35:1186–92.CrossRefPubMed
32.
go back to reference Carlile PV, Beckett RC, Gray BA. Relationship between co and transit times for dye and thermal indicators in central circulation. J Appl Physiol. 1986;60:1363–72.PubMed Carlile PV, Beckett RC, Gray BA. Relationship between co and transit times for dye and thermal indicators in central circulation. J Appl Physiol. 1986;60:1363–72.PubMed
33.
go back to reference Hill SL, Elings VB, Lewis F. Effect of cardiac output on extravascular lung water. Am Surg. 1981;47:522–8.PubMed Hill SL, Elings VB, Lewis F. Effect of cardiac output on extravascular lung water. Am Surg. 1981;47:522–8.PubMed
34.
go back to reference Nusmeier A, Vrancken S, de Boode WP, van der Hoeven JG, Lemson J. Validation of extravascular lung water measurement by transpulmonary thermodilution in a pediatric animal model. Pediatr Crit Care Med. 2014;15:e226–33.CrossRefPubMed Nusmeier A, Vrancken S, de Boode WP, van der Hoeven JG, Lemson J. Validation of extravascular lung water measurement by transpulmonary thermodilution in a pediatric animal model. Pediatr Crit Care Med. 2014;15:e226–33.CrossRefPubMed
35.
go back to reference Roch A, Michelet P, Lambert D, Delliaux S, Saby C, Perrin G, Ghez O, Bregeon F, Thomas P, Carpentier JP, Papazian L, Auffray JP. Accuracy of the double indicator method for measurement of extravascular lung water depends on the type of acute lung injury. Crit Care Med. 2004;32:811–7.CrossRefPubMed Roch A, Michelet P, Lambert D, Delliaux S, Saby C, Perrin G, Ghez O, Bregeon F, Thomas P, Carpentier JP, Papazian L, Auffray JP. Accuracy of the double indicator method for measurement of extravascular lung water depends on the type of acute lung injury. Crit Care Med. 2004;32:811–7.CrossRefPubMed
36.
go back to reference Rossi P, Oldner A, Wanecek M, Leksell LG, Rudehill A, Konrad D, Weitzberg E. Comparison of gravimetric and a double-indicator dilution technique for assessment of extra-vascular lung water in endotoxaemia. Intensive Care Med. 2003;29:460–6.CrossRefPubMed Rossi P, Oldner A, Wanecek M, Leksell LG, Rudehill A, Konrad D, Weitzberg E. Comparison of gravimetric and a double-indicator dilution technique for assessment of extra-vascular lung water in endotoxaemia. Intensive Care Med. 2003;29:460–6.CrossRefPubMed
37.
go back to reference Raimondi F, Migliaro F, Sodano A, Umbaldo A, Romano A, Vallone G, Capasso L. Can neonatal lung ultrasound monitor fluid clearance and predict the need of respiratory support? Crit Care. 2012;16:R220.CrossRefPubMedPubMedCentral Raimondi F, Migliaro F, Sodano A, Umbaldo A, Romano A, Vallone G, Capasso L. Can neonatal lung ultrasound monitor fluid clearance and predict the need of respiratory support? Crit Care. 2012;16:R220.CrossRefPubMedPubMedCentral
38.
go back to reference Seghaye MC, Grabitz RG, Duchateau J, Busse S, Dabritz S, Koch D, Alzen G, Hornchen H, Messmer BJ, Von Bernuth G. Inflammatory reaction and capillary leak syndrome related to cardiopulmonary bypass in neonates undergoing cardiac operations. J Thorac Cardiovasc Surg. 1996;112:687–97.CrossRefPubMed Seghaye MC, Grabitz RG, Duchateau J, Busse S, Dabritz S, Koch D, Alzen G, Hornchen H, Messmer BJ, Von Bernuth G. Inflammatory reaction and capillary leak syndrome related to cardiopulmonary bypass in neonates undergoing cardiac operations. J Thorac Cardiovasc Surg. 1996;112:687–97.CrossRefPubMed
39.
go back to reference Lemson J, van Die LE, Hemelaar AE, van der Hoeven JG. Extravascular lung water index measurement in critically ill children does not correlate with a chest x-ray score of pulmonary edema. Crit Care. 2010;14:R105.CrossRefPubMedPubMedCentral Lemson J, van Die LE, Hemelaar AE, van der Hoeven JG. Extravascular lung water index measurement in critically ill children does not correlate with a chest x-ray score of pulmonary edema. Crit Care. 2010;14:R105.CrossRefPubMedPubMedCentral
Metadata
Title
Estimation of extravascular lung water using the transpulmonary ultrasound dilution (TPUD) method: a validation study in neonatal lambs
Authors
S. L. Vrancken
A. Nusmeier
J. C. Hopman
K. D. Liem
J. G. van der Hoeven
J. Lemson
A. F. van Heijst
W. P. de Boode
Publication date
01-12-2016
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 6/2016
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9803-7

Other articles of this Issue 6/2016

Journal of Clinical Monitoring and Computing 6/2016 Go to the issue