Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 2/2016

01-04-2016 | Original Research

Bioelectrical impedance spectroscopy to estimate fluid balance in critically ill patients

Authors: Antoine Dewitte, Pauline Carles, Olivier Joannès-Boyau, Catherine Fleureau, Hadrien Roze, Christian Combe, Alexandre Ouattara

Published in: Journal of Clinical Monitoring and Computing | Issue 2/2016

Login to get access

Abstract

Fluid management is a crucial issue in intensive-care medicine. This study evaluated the feasibility and reproducibility of bioimpedance spectroscopy to measure body-water composition in critically ill patients, and compared fluid balance and daily changes in total body water (TBW) measured by bioimpedance. This observational study included 25 patients under mechanical ventilation. Fluid balance and bioimpedance measurements were recorded on 3 consecutive days. Whole-body bioimpedance spectroscopy was performed with exact or ideal body weights entered into the device, and with or without ICU monitoring. Reproducibility of bioimpedance spectroscopy was very good in all conditions despite ICU monitoring and mechanical ventilation. Bioimpedance measurements using an ideal body weight varied significantly, making the weighing procedure necessary. Comparison of fluid balance and daily changes in body weight provided the best correlation (ρ = 0.74; P < 0.0001). Daily changes in TBW were correlated with fluid balance (Spearman coefficient ρ = 0.31; P = 0.003) and this correlation was improved after exclusion of patients with a SOFA score >10 (ρ = 0.36; P = 0.05) and with extracorporeal circulation (ρ = 0.50; P = 0.005). Regardless of the technique used to estimate volume status, important limits of agreement were observed. Non-invasive determination of body-water composition using bioimpedance spectroscopy is feasible in critically ill patients but requires knowledge of the patient’s weight. The best method to assess volume status after fluid resuscitation and the value gained from information about body composition provided by bioimpedance techniques needs further evaluation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, Peterson E, Tomlanovich M, Early Goal-Directed Therapy Collaborative G. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med. 2001;345(19):1368–77. doi:10.1056/NEJMoa010307.CrossRefPubMed Rivers E, Nguyen B, Havstad S, Ressler J, Muzzin A, Knoblich B, Peterson E, Tomlanovich M, Early Goal-Directed Therapy Collaborative G. Early goal-directed therapy in the treatment of severe sepsis and septic shock. N Engl J Med. 2001;345(19):1368–77. doi:10.​1056/​NEJMoa010307.CrossRefPubMed
2.
3.
go back to reference National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network, Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, deBoisblanc B, Connors AF Jr, Hite RD, Harabin AL. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med. 2006;354(24):2564–75. doi:10.1056/NEJMoa062200. National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network, Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, deBoisblanc B, Connors AF Jr, Hite RD, Harabin AL. Comparison of two fluid-management strategies in acute lung injury. N Engl J Med. 2006;354(24):2564–75. doi:10.​1056/​NEJMoa062200.
4.
go back to reference Koobi T, Kahonen M, Koskinen M, Kaukinen S, Turjanmaa VM. Comparison of bioimpedance and radioisotope methods in the estimation of extracellular water volume before and after coronary artery bypass grafting operation. Clin Physiol. 2000;20(4):283–91.CrossRefPubMed Koobi T, Kahonen M, Koskinen M, Kaukinen S, Turjanmaa VM. Comparison of bioimpedance and radioisotope methods in the estimation of extracellular water volume before and after coronary artery bypass grafting operation. Clin Physiol. 2000;20(4):283–91.CrossRefPubMed
5.
go back to reference Network VNARFT, Palevsky PM, Zhang JH, O’Connor TZ, Chertow GM, Crowley ST, Choudhury D, Finkel K, Kellum JA, Paganini E, Schein RM, Smith MW, Swanson KM, Thompson BT, Vijayan A, Watnick S, Star RA, Peduzzi P. Intensity of renal support in critically ill patients with acute kidney injury. N Engl J Med. 2008;359(1):7–20. doi:10.1056/NEJMoa0802639.CrossRef Network VNARFT, Palevsky PM, Zhang JH, O’Connor TZ, Chertow GM, Crowley ST, Choudhury D, Finkel K, Kellum JA, Paganini E, Schein RM, Smith MW, Swanson KM, Thompson BT, Vijayan A, Watnick S, Star RA, Peduzzi P. Intensity of renal support in critically ill patients with acute kidney injury. N Engl J Med. 2008;359(1):7–20. doi:10.​1056/​NEJMoa0802639.CrossRef
6.
go back to reference Schneider AG, Baldwin I, Freitag E, Glassford N, Bellomo R. Estimation of fluid status changes in critically ill patients: fluid balance chart or electronic bed weight? J Crit Care. 2012;27(6):745 e747–712. doi:10.1016/j.jcrc.2011.12.017. Schneider AG, Baldwin I, Freitag E, Glassford N, Bellomo R. Estimation of fluid status changes in critically ill patients: fluid balance chart or electronic bed weight? J Crit Care. 2012;27(6):745 e747–712. doi:10.​1016/​j.​jcrc.​2011.​12.​017.
7.
go back to reference Perren A, Markmann M, Merlani G, Marone C, Merlani P. Fluid balance in critically ill patients. Should we really rely on it? Minerva Anestesiol. 2011;77(8):802–11.PubMed Perren A, Markmann M, Merlani G, Marone C, Merlani P. Fluid balance in critically ill patients. Should we really rely on it? Minerva Anestesiol. 2011;77(8):802–11.PubMed
8.
go back to reference Roos AN, Westendorp RG, Frolich M, Meinders AE. Weight changes in critically ill patients evaluated by fluid balances and impedance measurements. Crit Care Med. 1993;21(6):871–7.CrossRefPubMed Roos AN, Westendorp RG, Frolich M, Meinders AE. Weight changes in critically ill patients evaluated by fluid balances and impedance measurements. Crit Care Med. 1993;21(6):871–7.CrossRefPubMed
10.
go back to reference Earthman C, Traughber D, Dobratz J, Howell W. Bioimpedance spectroscopy for clinical assessment of fluid distribution and body cell mass. Nutr Clin Pract. 2007;22(4):389–405.CrossRefPubMed Earthman C, Traughber D, Dobratz J, Howell W. Bioimpedance spectroscopy for clinical assessment of fluid distribution and body cell mass. Nutr Clin Pract. 2007;22(4):389–405.CrossRefPubMed
11.
go back to reference Buchholz AC, Bartok C, Schoeller DA. The validity of bioelectrical impedance models in clinical populations. Nutr Clin Pract. 2004;19(5):433–46.CrossRefPubMed Buchholz AC, Bartok C, Schoeller DA. The validity of bioelectrical impedance models in clinical populations. Nutr Clin Pract. 2004;19(5):433–46.CrossRefPubMed
12.
go back to reference Moissl UM, Wabel P, Chamney PW, Bosaeus I, Levin NW, Bosy-Westphal A, Korth O, Muller MJ, Ellegard L, Malmros V, Kaitwatcharachai C, Kuhlmann MK, Zhu F, Fuller NJ. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas. 2006;27(9):921–33. doi:10.1088/0967-3334/27/9/012.CrossRefPubMed Moissl UM, Wabel P, Chamney PW, Bosaeus I, Levin NW, Bosy-Westphal A, Korth O, Muller MJ, Ellegard L, Malmros V, Kaitwatcharachai C, Kuhlmann MK, Zhu F, Fuller NJ. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas. 2006;27(9):921–33. doi:10.​1088/​0967-3334/​27/​9/​012.CrossRefPubMed
14.
go back to reference Chamney PW, Wabel P, Moissl UM, Muller MJ, Bosy-Westphal A, Korth O, Fuller NJ. A whole-body model to distinguish excess fluid from the hydration of major body tissues. Am J Clin Nutr. 2007;85(1):80–9.PubMed Chamney PW, Wabel P, Moissl UM, Muller MJ, Bosy-Westphal A, Korth O, Fuller NJ. A whole-body model to distinguish excess fluid from the hydration of major body tissues. Am J Clin Nutr. 2007;85(1):80–9.PubMed
15.
go back to reference Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86(2):420–8.CrossRefPubMed Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psychol Bull. 1979;86(2):420–8.CrossRefPubMed
16.
go back to reference Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRefPubMed Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRefPubMed
17.
go back to reference Valentinuzzi ME, Morucci JP, Felice CJ. Bioelectrical impedance techniques in medicine. Part II: monitoring of physiological events by impedance. Crit Rev Biomed Eng. 1996;24(4–6):353–466.PubMed Valentinuzzi ME, Morucci JP, Felice CJ. Bioelectrical impedance techniques in medicine. Part II: monitoring of physiological events by impedance. Crit Rev Biomed Eng. 1996;24(4–6):353–466.PubMed
18.
go back to reference Foley K, Keegan M, Campbell I, Murby B, Hancox D, Pollard B. Use of single-frequency bioimpedance at 50 kHz to estimate total body water in patients with multiple organ failure and fluid overload. Crit Care Med. 1999;27(8):1472–7.CrossRefPubMed Foley K, Keegan M, Campbell I, Murby B, Hancox D, Pollard B. Use of single-frequency bioimpedance at 50 kHz to estimate total body water in patients with multiple organ failure and fluid overload. Crit Care Med. 1999;27(8):1472–7.CrossRefPubMed
19.
go back to reference Thomasset A. Bio-electric properties of tissues. Estimation by measurement of impedance of extracellular ionic strength and intracellular ionic strength in the clinic. Lyon Med. 1963;209:1325–50.PubMed Thomasset A. Bio-electric properties of tissues. Estimation by measurement of impedance of extracellular ionic strength and intracellular ionic strength in the clinic. Lyon Med. 1963;209:1325–50.PubMed
20.
go back to reference Patel RV, Peterson EL, Silverman N, Zarowitz BJ. Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance. Crit Care Med. 1996;24(11):1824–8.CrossRefPubMed Patel RV, Peterson EL, Silverman N, Zarowitz BJ. Estimation of total body and extracellular water in post-coronary artery bypass graft surgical patients using single and multiple frequency bioimpedance. Crit Care Med. 1996;24(11):1824–8.CrossRefPubMed
21.
go back to reference Plank LD, Monk DN, Woollard GA, Hill GL. Evaluation of multifrequency bioimpedance spectroscopy for measurement of the extracellular water space in critically ill patients. Appl Radiat Isot. 1998;49(5–6):481–3.CrossRefPubMed Plank LD, Monk DN, Woollard GA, Hill GL. Evaluation of multifrequency bioimpedance spectroscopy for measurement of the extracellular water space in critically ill patients. Appl Radiat Isot. 1998;49(5–6):481–3.CrossRefPubMed
22.
go back to reference Faisy C, Rabbat A, Kouchakji B, Laaban JP. Bioelectrical impedance analysis in estimating nutritional status and outcome of patients with chronic obstructive pulmonary disease and acute respiratory failure. Intensive Care Med. 2000;26(5):518–25.CrossRefPubMed Faisy C, Rabbat A, Kouchakji B, Laaban JP. Bioelectrical impedance analysis in estimating nutritional status and outcome of patients with chronic obstructive pulmonary disease and acute respiratory failure. Intensive Care Med. 2000;26(5):518–25.CrossRefPubMed
23.
go back to reference Earthman CP, Matthie JR, Reid PM, Harper IT, Ravussin E, Howell WH. A comparison of bioimpedance methods for detection of body cell mass change in HIV infection. J Appl Physiol. 2000;88(3):944–56.PubMed Earthman CP, Matthie JR, Reid PM, Harper IT, Ravussin E, Howell WH. A comparison of bioimpedance methods for detection of body cell mass change in HIV infection. J Appl Physiol. 2000;88(3):944–56.PubMed
24.
go back to reference Cox-Reijven PL, van Kreel B, Soeters PB. Accuracy of bioelectrical impedance spectroscopy in measuring changes in body composition during severe weight loss. J Parenter Enter Nutr. 2002;26(2):120–7.CrossRef Cox-Reijven PL, van Kreel B, Soeters PB. Accuracy of bioelectrical impedance spectroscopy in measuring changes in body composition during severe weight loss. J Parenter Enter Nutr. 2002;26(2):120–7.CrossRef
26.
go back to reference Balik M, Sedivy J, Waldauf P, Kolar M, Smejkalova V, Pachl J. Can bioimpedance determine the volume of distribution of antibiotics in sepsis? Anaesth Intensive Care. 2005;33(3):345–50.PubMed Balik M, Sedivy J, Waldauf P, Kolar M, Smejkalova V, Pachl J. Can bioimpedance determine the volume of distribution of antibiotics in sepsis? Anaesth Intensive Care. 2005;33(3):345–50.PubMed
27.
go back to reference Piccoli A, Pittoni G, Facco E, Favaro E, Pillon L. Relationship between central venous pressure and bioimpedance vector analysis in critically ill patients. Crit Care Med. 2000;28(1):132–7.CrossRefPubMed Piccoli A, Pittoni G, Facco E, Favaro E, Pillon L. Relationship between central venous pressure and bioimpedance vector analysis in critically ill patients. Crit Care Med. 2000;28(1):132–7.CrossRefPubMed
Metadata
Title
Bioelectrical impedance spectroscopy to estimate fluid balance in critically ill patients
Authors
Antoine Dewitte
Pauline Carles
Olivier Joannès-Boyau
Catherine Fleureau
Hadrien Roze
Christian Combe
Alexandre Ouattara
Publication date
01-04-2016
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2016
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9706-7

Other articles of this Issue 2/2016

Journal of Clinical Monitoring and Computing 2/2016 Go to the issue