A Handy EEG Electrode Set for patients suffering from altered mental state

Authors: Pasi Lepola, Sami Myllymaa, Juha Töyräs, Taina Hukkanen, Esa Mervaala, Sara Määttä, Reijo Lappalainen, Katja Myllymaa

Published in: Journal of Clinical Monitoring and Computing | Issue 6/2015

Login to get access

Abstract

Although electroencephalography (EEG) is an important diagnostic tool for investigating patients with unexplained altered mental state (AMS), recording of emergency EEG is not a clinical routine. This is mainly due to the cumbersome electrode solutions. A Handy EEG Electrode Set consists of ten EEG, two EOG, two ground and two commutative reference hydrogel-coated silver wire electrodes attached to a thin polyester carrier film. The clinical usefulness of the Handy EEG Electrode Set was tested in 13 patients (five females, eight males) with AMS. EEG recordings were conducted at the same time with a standard 10–20 electrode set. The registration in the first patient case without the behind-ear electrodes (T9 and T10), indicated that these electrodes are very crucial to provide clinically relevant information from posterior regions of brain. In following 12 cases, the sensitivity and specificity for detecting EEG abnormality based on the Handy EEG Electrode Set recordings were 83 and 100 %, respectively. The Handy EEG Electrode Set proved to be easy to use and to provide valuable information for the neurophysiological evaluation of a patient suffering from AMS. However, further studies with larger number of patients are warranted to clarify the true diagnostic accuracy and applicability of this approach.
Literature
1.
go back to reference Noachtar S, Rémi J. The role of EEG in epilepsy: a critical review. Epilepsy Behav. 2009;15(1):22–33.CrossRefPubMed Noachtar S, Rémi J. The role of EEG in epilepsy: a critical review. Epilepsy Behav. 2009;15(1):22–33.CrossRefPubMed
2.
go back to reference Bearden ST, Nay LB. Utility of EEG in differential diagnosis of adults with unexplained acute alteration of mental status. Am J Electroneurodiagn Technol. 2011;51(2):92–104. Bearden ST, Nay LB. Utility of EEG in differential diagnosis of adults with unexplained acute alteration of mental status. Am J Electroneurodiagn Technol. 2011;51(2):92–104.
3.
go back to reference Borges MA, Botós HJ, Bastos RF, Godoy MF, de Marchi NSA. Emergency EEG study of survival. Arq Neuro-Psiquiatr. 2010;68(2):174–8.CrossRef Borges MA, Botós HJ, Bastos RF, Godoy MF, de Marchi NSA. Emergency EEG study of survival. Arq Neuro-Psiquiatr. 2010;68(2):174–8.CrossRef
4.
go back to reference Praline J, Grujic J, Corcia P, Lucas B, Hommet C, Autret A, de Toffol B. Emergent EEG in clinical practice. Clin Neurophysiol. 2007;118(10):2149–55.CrossRefPubMed Praline J, Grujic J, Corcia P, Lucas B, Hommet C, Autret A, de Toffol B. Emergent EEG in clinical practice. Clin Neurophysiol. 2007;118(10):2149–55.CrossRefPubMed
5.
go back to reference Ricardo JAG, França MC Jr, Lima FO, Yassuda CL, Cendes F. The impact of EEG in the diagnosis and management of patients with acute impairment of consciousness. Arq Neuropsiquiatr. 2012;70(1):34–9.CrossRefPubMed Ricardo JAG, França MC Jr, Lima FO, Yassuda CL, Cendes F. The impact of EEG in the diagnosis and management of patients with acute impairment of consciousness. Arq Neuropsiquiatr. 2012;70(1):34–9.CrossRefPubMed
6.
go back to reference Yigit O, Eray O, Mihci E, Yilmaz D, Arslan S, Eray B. The utility of EEG in the emergency department. Emerg Med J. 2012;29(4):301–5.CrossRefPubMed Yigit O, Eray O, Mihci E, Yilmaz D, Arslan S, Eray B. The utility of EEG in the emergency department. Emerg Med J. 2012;29(4):301–5.CrossRefPubMed
7.
go back to reference Ziai WC, Schlattman D, Llinas R, Venkatesha S, Truesdale M, Schevchenko A, Kaplan PW. Emergent EEG in the emergency department in patients with altered mental states. Clin Neurophysiol. 2012;123(5):910–7.CrossRefPubMed Ziai WC, Schlattman D, Llinas R, Venkatesha S, Truesdale M, Schevchenko A, Kaplan PW. Emergent EEG in the emergency department in patients with altered mental states. Clin Neurophysiol. 2012;123(5):910–7.CrossRefPubMed
8.
go back to reference Baki SGA, Omurtag A, Fenton AA, Zehtabchi S. The new wave: time to bring EEG to the emergency department. Int J Emer Med. 2011;4(1):1–7.CrossRef Baki SGA, Omurtag A, Fenton AA, Zehtabchi S. The new wave: time to bring EEG to the emergency department. Int J Emer Med. 2011;4(1):1–7.CrossRef
9.
go back to reference Claassen J, Mayer SA, Kowalski RG, Emerson RG, Hirsch LJ. Detection of electrographic seizures with continuous EEG monitoring in critically ill patients. Neurology. 2004;62(10):1743–8.CrossRefPubMed Claassen J, Mayer SA, Kowalski RG, Emerson RG, Hirsch LJ. Detection of electrographic seizures with continuous EEG monitoring in critically ill patients. Neurology. 2004;62(10):1743–8.CrossRefPubMed
10.
go back to reference Murthy JMK, Jayashree Naryanan T. Continuous EEG monitoring in the evaluation of non-convulsive seizures and status epilepticus. Neurol India. 2004;52(4):430–5.PubMed Murthy JMK, Jayashree Naryanan T. Continuous EEG monitoring in the evaluation of non-convulsive seizures and status epilepticus. Neurol India. 2004;52(4):430–5.PubMed
11.
go back to reference Sutter R, Stevens RD, Kaplan PW. Continuous electroencephalographic monitoring in critically ill patients: indications, limitations, and strategies. Crit Care Med. 2013;41(4):1124–32.CrossRefPubMed Sutter R, Stevens RD, Kaplan PW. Continuous electroencephalographic monitoring in critically ill patients: indications, limitations, and strategies. Crit Care Med. 2013;41(4):1124–32.CrossRefPubMed
12.
go back to reference Young GB, Jordan KG, Doig GS. An assessment of nonconvulsive seizures in the intensive care unit using continuous EEG monitoring: an investigation of variables associated with mortality. Neurology. 1996;47(1):83–9.CrossRefPubMed Young GB, Jordan KG, Doig GS. An assessment of nonconvulsive seizures in the intensive care unit using continuous EEG monitoring: an investigation of variables associated with mortality. Neurology. 1996;47(1):83–9.CrossRefPubMed
13.
go back to reference Young GB, Sharpe MD, Savard M, Al Thenayan E, Norton L, Davies-Schinkel C. Seizure detection with a commercially available bedside EEG monitor and the subhairline montage. Neurocrit Care. 2009;11(3):411–6.CrossRefPubMed Young GB, Sharpe MD, Savard M, Al Thenayan E, Norton L, Davies-Schinkel C. Seizure detection with a commercially available bedside EEG monitor and the subhairline montage. Neurocrit Care. 2009;11(3):411–6.CrossRefPubMed
14.
go back to reference Towne AR, Pellock JM, Ko D, DeLorenzo RJ. Determinants of mortality in status epilepticus. Epilepsia. 1994;35(1):27–34.CrossRefPubMed Towne AR, Pellock JM, Ko D, DeLorenzo RJ. Determinants of mortality in status epilepticus. Epilepsia. 1994;35(1):27–34.CrossRefPubMed
15.
go back to reference Pokela M, Jäntti V, Lepola P, Romsi P, Rimpiläinen J, Kiviluoma K, Salomäki T, Vainionpää V, Biancari F, Hirvonen J, Kaakinen T, Juvonen T. EEG burst recovery is predictive of brain injury after experimental hypothermic circulatory arrest. Scand Cardiovasc J. 2003;37(3):154–7.CrossRefPubMed Pokela M, Jäntti V, Lepola P, Romsi P, Rimpiläinen J, Kiviluoma K, Salomäki T, Vainionpää V, Biancari F, Hirvonen J, Kaakinen T, Juvonen T. EEG burst recovery is predictive of brain injury after experimental hypothermic circulatory arrest. Scand Cardiovasc J. 2003;37(3):154–7.CrossRefPubMed
16.
17.
go back to reference Kolls BJ, Husain AM. Assessment of hairline EEG as a screening tool for nonconvulsive status epilepticus. Epilepsia. 2007;48(5):959–65.CrossRefPubMed Kolls BJ, Husain AM. Assessment of hairline EEG as a screening tool for nonconvulsive status epilepticus. Epilepsia. 2007;48(5):959–65.CrossRefPubMed
18.
go back to reference Myllymaa S, Lepola P, Töyräs J, Hukkanen T, Mervaala E, Lappalainen R, Myllymaa K. New disposable forehead electrode set with excellent signal quality and imaging compatibility. J Neurosci Methods. 2013;215(1):103–9.CrossRefPubMed Myllymaa S, Lepola P, Töyräs J, Hukkanen T, Mervaala E, Lappalainen R, Myllymaa K. New disposable forehead electrode set with excellent signal quality and imaging compatibility. J Neurosci Methods. 2013;215(1):103–9.CrossRefPubMed
19.
go back to reference Bridgers SL, Ebersole JS. EEG outside the hairline: detection of epileptiform abnormalities. Neurology. 1988;38(1):146–9.CrossRefPubMed Bridgers SL, Ebersole JS. EEG outside the hairline: detection of epileptiform abnormalities. Neurology. 1988;38(1):146–9.CrossRefPubMed
20.
go back to reference Bubrick EJ, Bromfield EB, Dworetzky BA. Utilization of below-the-hairline EEG in detecting subclinical seizures. Clin EEG Neurosci. 2010;41(1):15–8.CrossRefPubMed Bubrick EJ, Bromfield EB, Dworetzky BA. Utilization of below-the-hairline EEG in detecting subclinical seizures. Clin EEG Neurosci. 2010;41(1):15–8.CrossRefPubMed
21.
go back to reference Goncharova II, McFarland DJ, Vaughan TM, Wolpaw JR. EMG contamination of EEG: spectral and topographical characteristics. Clin Neurophysiol. 2003;114(9):1580–93.CrossRefPubMed Goncharova II, McFarland DJ, Vaughan TM, Wolpaw JR. EMG contamination of EEG: spectral and topographical characteristics. Clin Neurophysiol. 2003;114(9):1580–93.CrossRefPubMed
22.
go back to reference Ma J, Tao P, Bayram A, Svetnik V. Muscle artifacts in multichannel EEG: characteristics and reduction. Clin Neurophysiol. 2012;123(8):1676–86.CrossRefPubMed Ma J, Tao P, Bayram A, Svetnik V. Muscle artifacts in multichannel EEG: characteristics and reduction. Clin Neurophysiol. 2012;123(8):1676–86.CrossRefPubMed
23.
go back to reference Kolls BJ, Olson DM, Gallentine WB, Skeen MB, Skidmore CT, Sinha SR. Electroencephalography leads placed by nontechnologists using a template system produce signals equal in quality to technologist-applied, collodion disk leads. J Clin Neurophysiol. 2012;29(1):42–9.CrossRefPubMed Kolls BJ, Olson DM, Gallentine WB, Skeen MB, Skidmore CT, Sinha SR. Electroencephalography leads placed by nontechnologists using a template system produce signals equal in quality to technologist-applied, collodion disk leads. J Clin Neurophysiol. 2012;29(1):42–9.CrossRefPubMed
Metadata
Title
A Handy EEG Electrode Set for patients suffering from altered mental state
Authors
Pasi Lepola
Sami Myllymaa
Juha Töyräs
Taina Hukkanen
Esa Mervaala
Sara Määttä
Reijo Lappalainen
Katja Myllymaa
Publication date
01-12-2015
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 6/2015
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-014-9652-9

Other articles of this Issue 6/2015

Journal of Clinical Monitoring and Computing 6/2015 Go to the issue