Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 1/2015

01-02-2015 | Original Research

Real-time two-dimensional and three-dimensional echocardiographic imaging of the thoracic spinal cord: a possible new window into the central neuraxis

Authors: Neil G. Feinglass, Steven R. Clendenen, Timothy S. J. Shine, Archer K. Martin, Roy A. Greengrass

Published in: Journal of Clinical Monitoring and Computing | Issue 1/2015

Login to get access

Abstract

Transesophageal echocardiography of the spine has been difficult to perform, and high-quality images have been difficult to obtain with earlier available technology. New capabilities in hardware and software reconstruction may allow more reliable clinical data to be obtained. We describe an initial successful attempt to image the adult spinal canal, its contents, and in situ instrumentation. This report is a retrospective review of two patients in whom transesophageal echocardiography (TEE) was used to image the thoracic spine. The thoracic spine was identified and imaged with real-time 2-D and 3-D technology with location of the thoracic aorta and slight insertion and withdrawal of the TEE probe until the intervertebral discs alignment was optimized. Images of the spinal cord anatomy and its vascular supply, as well as indwelling epidural catheters were easily identified. 2-D and 3-D imaging was performed and images were recorded in digital imaging and communications in medicine format. 3-D reconstruction of images was possible with instantaneous 3-D imaging from multiple 2-D electrocardiogram-gated image acquisitions using the Phillips TEE IE-33 imaging platform. The central neuraxial cavity, including the spinal cord and the spinal nerve roots, was easily visualized, and motion of the cord was seen in a phasic pattern (with respiratory variation); cerebrospinal fluid surrounding the spinal cord was documented. The epidural space and local anesthetic drug administration through the epidural catheter were visualized, with the epidural catheter seen lying adjacent to the epidural tissue as a bright hyperechoic line. Pulsed-wave Doppler determined a biphasic pattern of blood flow in the anterior spinal artery through pulse mapping of the anatomic area. New, advanced imaging hardware and software generate clinically useful imaging of the thoracic spine in 2-D and 3-D using TEE. We believe this technology holds promise for future diagnostic and therapeutic interventions in the operating room that were previously unavailable.
Appendix
Available only for authorised users
Literature
1.
go back to reference Shine TS, Harrison BA, De Ruyter ML, Crook JE, Heckman M, Daube JR, Stapelfeldt WH, Cherry KJ, Gloviczki P, Bower TC, Murray MJ. Motor and somatosensory evoked potentials: their role in predicting spinal cord ischemia in patients undergoing thoracoabdominal aortic aneurysm repair with regional lumbar epidural cooling. Anesthesiology. 2008;108:580–7.PubMedCrossRef Shine TS, Harrison BA, De Ruyter ML, Crook JE, Heckman M, Daube JR, Stapelfeldt WH, Cherry KJ, Gloviczki P, Bower TC, Murray MJ. Motor and somatosensory evoked potentials: their role in predicting spinal cord ischemia in patients undergoing thoracoabdominal aortic aneurysm repair with regional lumbar epidural cooling. Anesthesiology. 2008;108:580–7.PubMedCrossRef
2.
go back to reference Sloan TB. Advancing the multidisciplinary approach to spinal cord injury risk reduction in thoracoabdominal aortic aneurysm repair. Anesthesiology. 2008;108:555–6.PubMedCrossRef Sloan TB. Advancing the multidisciplinary approach to spinal cord injury risk reduction in thoracoabdominal aortic aneurysm repair. Anesthesiology. 2008;108:555–6.PubMedCrossRef
3.
go back to reference Nath MP, Gupta S, Kiran U, Chauhan S, Dhawan N. Spinal cord Imaging by transesophageal echocardiography: a new modality of monitoring. Acta Anaesthesiologica Taiwanica. 2011;49(3):114–5.PubMedCrossRef Nath MP, Gupta S, Kiran U, Chauhan S, Dhawan N. Spinal cord Imaging by transesophageal echocardiography: a new modality of monitoring. Acta Anaesthesiologica Taiwanica. 2011;49(3):114–5.PubMedCrossRef
4.
go back to reference Sugeng L, Shernan S, et al. Live 3-dimensional transesophageal echocardiography: initial experience using the fully-sampled matrix array probe. J Am Coll Cardiol. 2008;52(6):446–9.PubMedCrossRef Sugeng L, Shernan S, et al. Live 3-dimensional transesophageal echocardiography: initial experience using the fully-sampled matrix array probe. J Am Coll Cardiol. 2008;52(6):446–9.PubMedCrossRef
5.
go back to reference Martin C, Stieg P. Vascular applications of the intraoperative magnetic resonance unit. Semin Neurosurg. 2000;11(1):71–826. Martin C, Stieg P. Vascular applications of the intraoperative magnetic resonance unit. Semin Neurosurg. 2000;11(1):71–826.
6.
go back to reference Young W, Tuma R, O’Grady T. Intraoperative measurement of spinal cord blood flow in syringomyelia. Clin Neurol Neurosurg. 2000;102(3):119–23.PubMedCrossRef Young W, Tuma R, O’Grady T. Intraoperative measurement of spinal cord blood flow in syringomyelia. Clin Neurol Neurosurg. 2000;102(3):119–23.PubMedCrossRef
7.
go back to reference Shine TSJ, Greengrass RA, Feinglass NG. Use of continuous paravertebral analgesia to facilitate neurologic assessment and enhance recovery after thoracoabdominal aortic aneurysm repair. Anesth Analg. 2004;98:1640–3.PubMedCrossRef Shine TSJ, Greengrass RA, Feinglass NG. Use of continuous paravertebral analgesia to facilitate neurologic assessment and enhance recovery after thoracoabdominal aortic aneurysm repair. Anesth Analg. 2004;98:1640–3.PubMedCrossRef
8.
go back to reference Woo E, et al. Spinal cord ischemia may be reduced via novel technique of intercostal artery revascularization during open thoracoabdominal aneurysm repair. J Vasc Surg. 2007;46(3):421–6.PubMedCrossRef Woo E, et al. Spinal cord ischemia may be reduced via novel technique of intercostal artery revascularization during open thoracoabdominal aneurysm repair. J Vasc Surg. 2007;46(3):421–6.PubMedCrossRef
9.
go back to reference Tabayashi K. Spinal cord protecting during thoracoabdominal aneurysm repair. Surg Today. 2005;35:1–6.PubMedCrossRef Tabayashi K. Spinal cord protecting during thoracoabdominal aneurysm repair. Surg Today. 2005;35:1–6.PubMedCrossRef
10.
go back to reference Zoli S, Roder F, et al. Predicting the risk of paraplegia after thoracic and thoracoabdominal aneurysm repair. Ann Thorac Surg. 2010;90(4):1237–44.PubMedCrossRef Zoli S, Roder F, et al. Predicting the risk of paraplegia after thoracic and thoracoabdominal aneurysm repair. Ann Thorac Surg. 2010;90(4):1237–44.PubMedCrossRef
11.
go back to reference Mitchell J, Kramschuster K. Real-time ultrasound measurements of changes in suboccipital vertebral artery diameter and blood flow velocity associated with cervical spine rotation. Physiother Res Int. 2008;13:241–54.PubMedCrossRef Mitchell J, Kramschuster K. Real-time ultrasound measurements of changes in suboccipital vertebral artery diameter and blood flow velocity associated with cervical spine rotation. Physiother Res Int. 2008;13:241–54.PubMedCrossRef
12.
go back to reference Carvalho JC. Ultrasound-facilitated epidurals and spinals in obstetrics. Anesthesiol Clin 2008;26:145-58, vii–viii. Carvalho JC. Ultrasound-facilitated epidurals and spinals in obstetrics. Anesthesiol Clin 2008;26:145-58, vii–viii.
13.
go back to reference Hotta K. Ultrasound-guided epidural block. Masui. 2008;57:556–63.PubMed Hotta K. Ultrasound-guided epidural block. Masui. 2008;57:556–63.PubMed
14.
go back to reference Kim SH, Lee KH, Yoon KB, Park WY, Yoon DM. Sonographic estimation of needle depth for cervical epidural blocks. Anesth Analg. 2008;106:1542–7.PubMedCrossRef Kim SH, Lee KH, Yoon KB, Park WY, Yoon DM. Sonographic estimation of needle depth for cervical epidural blocks. Anesth Analg. 2008;106:1542–7.PubMedCrossRef
15.
go back to reference Rofaeel A, Peng P, Louis I, Chan V. Feasibility of real-time ultrasound for pudendal nerve block in patients with chronic perineal pain. Reg Anesth Pain Med. 2008;33:139–45.PubMedCrossRef Rofaeel A, Peng P, Louis I, Chan V. Feasibility of real-time ultrasound for pudendal nerve block in patients with chronic perineal pain. Reg Anesth Pain Med. 2008;33:139–45.PubMedCrossRef
16.
go back to reference Lee Y, Tanaka M. Carvalho JC.: sonoanatomy of the lumbar spine in patients with previous unintentional dural punctures during labor epidurals. Reg Anesth Pain Med. 2008;33:266–70.PubMedCrossRef Lee Y, Tanaka M. Carvalho JC.: sonoanatomy of the lumbar spine in patients with previous unintentional dural punctures during labor epidurals. Reg Anesth Pain Med. 2008;33:266–70.PubMedCrossRef
17.
go back to reference Tsui B, Dillane D, Pillay J, Walji A. Ultrasound imaging in cadavers: training in imaging for regional blockade at the trunk. Can J Anaesth. 2008;55:105–11.PubMedCrossRef Tsui B, Dillane D, Pillay J, Walji A. Ultrasound imaging in cadavers: training in imaging for regional blockade at the trunk. Can J Anaesth. 2008;55:105–11.PubMedCrossRef
Metadata
Title
Real-time two-dimensional and three-dimensional echocardiographic imaging of the thoracic spinal cord: a possible new window into the central neuraxis
Authors
Neil G. Feinglass
Steven R. Clendenen
Timothy S. J. Shine
Archer K. Martin
Roy A. Greengrass
Publication date
01-02-2015
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 1/2015
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-014-9576-4

Other articles of this Issue 1/2015

Journal of Clinical Monitoring and Computing 1/2015 Go to the issue