Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 6/2014

01-12-2014 | Original Paper

Non-invasive cardiac output evaluation in postoperative cardiac surgery patients, using a new prolonged expiration-based technique

Authors: Alessia Mattei, Emiliano Schena, Stefano Cecchini, Paola Proscia, Paola Saccomandi, Sergio Silvestri, Massimiliano Carassiti

Published in: Journal of Clinical Monitoring and Computing | Issue 6/2014

Login to get access

Abstract

The gold standard methods to measure cardiac output (CO) are invasive and expose the patient to high risks of various complications. The aim of this study is to assess an innovative non-invasive method for CO monitoring in mechanically ventilated patients after cardiac surgery and its agreement with values obtained by thermodilution technique. Continuous monitoring of respiratory gas concentrations and airflow allows the estimation of CO through a newly developed algorithm derived from a modified version of the Fick equation. It consists of two phases: the first involves measurements during steady breathing state, and the second starts when a sudden perturbation into the carbon dioxide elimination process is introduced by a prolonged expiration. This prospective clinical study involved thirty-five adult patients, undergone cardiac surgery. The measurements were performed in curarized and haemodynamically stable patients, during the post-surgery recovery in intensive care unit. The study protocol, which lasted 1 h for each patient, consisted of 20 measurements obtained by prolonged expiration-based method and 10 by thermodilution. The estimation of CO using the proposed method (COK) agreed with the thermodilution (COT) as demonstrated by: a low mean bias between COK and COT considering all patients (i.e., −0.11 L min−1); a best fitting line having slope = 0.98, r = 0.81, p < 0.0001; the lower and upper limits of agreement were −0.77 and +0.54 L min−1, respectively. COK shows a mean percentage error of 34 %. In stable mechanically ventilated patients, undergone cardiac surgery, the proposed method is reliable if compared to the thermodilution. Considering the non-invasivity of the technique, further evaluations of its performances are encouraged.
Literature
1.
go back to reference Norman RA, Johnson RW, Messinger JE, Sohrab B. A continuous cardiac output computer based on thermodilution principles. Ann Biomed Eng. 1989;17:61–73.CrossRef Norman RA, Johnson RW, Messinger JE, Sohrab B. A continuous cardiac output computer based on thermodilution principles. Ann Biomed Eng. 1989;17:61–73.CrossRef
2.
go back to reference Rivers E, Nguyen B, Havstad S. Early goal directed therapy in the treatment of sepsis and severe shock septic. N Engl J Med. 2001;345:1368–77.CrossRefPubMed Rivers E, Nguyen B, Havstad S. Early goal directed therapy in the treatment of sepsis and severe shock septic. N Engl J Med. 2001;345:1368–77.CrossRefPubMed
3.
go back to reference Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.CrossRefPubMed Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.CrossRefPubMed
4.
go back to reference Gedeon A, Forslund L, Hedenstierna G, Romano E. A new method for noninvasive bedside determination of pulmonary blood flow. Med Biol Eng Comput. 2002;17:313–21. Gedeon A, Forslund L, Hedenstierna G, Romano E. A new method for noninvasive bedside determination of pulmonary blood flow. Med Biol Eng Comput. 2002;17:313–21.
5.
go back to reference Peyton PJ, Thompson D, Junior P. Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO2 Fick method. J Clin Monit Comput. 2008;22:285–92.CrossRefPubMed Peyton PJ, Thompson D, Junior P. Non-invasive automated measurement of cardiac output during stable cardiac surgery using a fully integrated differential CO2 Fick method. J Clin Monit Comput. 2008;22:285–92.CrossRefPubMed
6.
go back to reference Haryadi DG, Orr JA, Kuck K, McJames S, Westenskow DR. Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output. J Clin Monit Comput. 2000;16:361–74.CrossRefPubMed Haryadi DG, Orr JA, Kuck K, McJames S, Westenskow DR. Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output. J Clin Monit Comput. 2000;16:361–74.CrossRefPubMed
7.
go back to reference Killick CJ, Parkin WG. Non-invasive cardiac output measurement using a fast mixing box to measure carbon dioxide elimination. Anaesth Intensive Care. 2008;36:665–73.PubMed Killick CJ, Parkin WG. Non-invasive cardiac output measurement using a fast mixing box to measure carbon dioxide elimination. Anaesth Intensive Care. 2008;36:665–73.PubMed
8.
go back to reference Cecchini S, Schena E, Notaro M, Carassiti M, Silvestri S. Non-invasive estimation of cardiac output in mechanically ventilated patients: a prolonged expiration method. Ann Biomed Eng. 2012;40:1777–89.CrossRefPubMed Cecchini S, Schena E, Notaro M, Carassiti M, Silvestri S. Non-invasive estimation of cardiac output in mechanically ventilated patients: a prolonged expiration method. Ann Biomed Eng. 2012;40:1777–89.CrossRefPubMed
9.
go back to reference Kim TS, Rahn H, Fahri LE. Estimation of true venous and arterial PCO2 by gas analysis of a single breath. J Appl Physiol. 1985;5:39–48. Kim TS, Rahn H, Fahri LE. Estimation of true venous and arterial PCO2 by gas analysis of a single breath. J Appl Physiol. 1985;5:39–48.
10.
go back to reference Mitchell RR. A deep breath method for noninvasive estimation of cardiopulmonary parameters. J Clin Monit Comput. 1988;5:53–64.CrossRef Mitchell RR. A deep breath method for noninvasive estimation of cardiopulmonary parameters. J Clin Monit Comput. 1988;5:53–64.CrossRef
11.
go back to reference Fick A. Uber die messung des blutquantums in den hertzventrikeln. Sitzungsberichte der Physiologisch Medizinosche Gesellschaft zu Wuerzburg. 1870;2:16. Fick A. Uber die messung des blutquantums in den hertzventrikeln. Sitzungsberichte der Physiologisch Medizinosche Gesellschaft zu Wuerzburg. 1870;2:16.
12.
go back to reference Jaffe MB. Partial CO2 rebreathing cardiac output operating principles of the NICO TM system. J Clin Monit Comput. 1999;15:387–401.CrossRefPubMed Jaffe MB. Partial CO2 rebreathing cardiac output operating principles of the NICO TM system. J Clin Monit Comput. 1999;15:387–401.CrossRefPubMed
13.
go back to reference Critchley LAZ, Critchley LAZ. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed Critchley LAZ, Critchley LAZ. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed
14.
go back to reference Godfrey S. Manipulation of the indirect Fick principle by a digital computer program for the calculation of exercise physiology results. Respiration. 1970;27:513–32.CrossRefPubMed Godfrey S. Manipulation of the indirect Fick principle by a digital computer program for the calculation of exercise physiology results. Respiration. 1970;27:513–32.CrossRefPubMed
15.
go back to reference Odenstadt H, Stenqvist O, Lundin S. Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients. Acta Anaesthesiol Scand. 2002;46:152–9.CrossRef Odenstadt H, Stenqvist O, Lundin S. Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients. Acta Anaesthesiol Scand. 2002;46:152–9.CrossRef
16.
go back to reference Botero M, Kirby D, Lobato EB, Staples ED, Gravenstein N. Measurement of cardiac output before and after cardio-pulmonary bypass: comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing. J Cardiothorac Vasc Anesth. 2004;18:563–72.CrossRefPubMed Botero M, Kirby D, Lobato EB, Staples ED, Gravenstein N. Measurement of cardiac output before and after cardio-pulmonary bypass: comparison among aortic transit-time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing. J Cardiothorac Vasc Anesth. 2004;18:563–72.CrossRefPubMed
17.
go back to reference Russell AE, Smith SA, West MJ, Aylward PE, McRitchie RJ, Hassam RM, et al. Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution. Br Heart J. 1990;63:195–9.CrossRefPubMedPubMedCentral Russell AE, Smith SA, West MJ, Aylward PE, McRitchie RJ, Hassam RM, et al. Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution. Br Heart J. 1990;63:195–9.CrossRefPubMedPubMedCentral
Metadata
Title
Non-invasive cardiac output evaluation in postoperative cardiac surgery patients, using a new prolonged expiration-based technique
Authors
Alessia Mattei
Emiliano Schena
Stefano Cecchini
Paola Proscia
Paola Saccomandi
Sergio Silvestri
Massimiliano Carassiti
Publication date
01-12-2014
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 6/2014
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-014-9563-9

Other articles of this Issue 6/2014

Journal of Clinical Monitoring and Computing 6/2014 Go to the issue