Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 3/2013

01-06-2013 | Original Research

Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches?

Authors: Derya Berk, Yavuz Gurkan, Alparslan Kus, Halim Ulugol, Mine Solak, Kamil Toker

Published in: Journal of Clinical Monitoring and Computing | Issue 3/2013

Login to get access

Abstract

Arterial cannulation with ultrasound (US) guidance increases the success rate and reduces complications. US-guided vascular access has two main approaches: long axis in-plane (LA-IP) and short axis out-of-plane (SA-OOP) approaches. The purpose of this study was to compare performance time and possible complications between two techniques. After obtaining ethics committee approval and informed patient consent, a prospective and randomized trial was conducted at ASA I-III, patients between the ages of 20–70 years. 108 patients were scheduled for radial arterial cannulaton in patients undergoing elective surgery under general anesthesia. Patients were divided into two groups as LA-IP and SA-OOP approaches with sealed envelope randomized method. After induction of anesthesia, the distance between skin-to-artery and the diameter of radial artery in US-imaging was recorded. The successful cannulation time, the number of attempts, potential complications such as thrombosis, edema, vasospasm, hematoma and posterior wall puncture were recorded. Demographic and hemodynamic parameters were similar in two groups. The diameter and the depth of artery were also similar in both of groups. Cannulation time was shorter in LA-IP Group compared to SA-OOP (24 ± 17 s vs. 47 ± 34 s respectively, p < 0.05). The arterial cannulation by LA-IP approach increased the rate of cannula-insertion success at the first attempt (76 %) compared to SA-OOP approach (51 %). Posterior wall damage during arterial cannulation were found in 30 patients with SA-OOP Group (56 %) and 11 patients with LA-IP Group (20 %), (p < 0.05). In our study, the use of LA-IP approach during US-guided radial artery cannulation has higher success rate at first insertion. We also found LA-IP approach results in shorter cannulation time and decreased the incidence of complications.
Literature
1.
go back to reference Scheer BV, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002;6:198–204.CrossRef Scheer BV, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002;6:198–204.CrossRef
2.
go back to reference Mangar D, Laborde RS, Vu DN. Delayed ischaemia of the hand necessitating amputation after radial artery cannulation. Can J Anaesth. 1993;40:247–50.PubMedCrossRef Mangar D, Laborde RS, Vu DN. Delayed ischaemia of the hand necessitating amputation after radial artery cannulation. Can J Anaesth. 1993;40:247–50.PubMedCrossRef
3.
go back to reference Levin PD, Sheinin O, Gozal Y. Use of ultrasound guidance in the insertion of radial artery catheters. Crit Care Med. 2003;31:481–4.PubMedCrossRef Levin PD, Sheinin O, Gozal Y. Use of ultrasound guidance in the insertion of radial artery catheters. Crit Care Med. 2003;31:481–4.PubMedCrossRef
4.
go back to reference Miller AH, Roth BA, Mills TJ, et al. Ultrasound guidance versus the landmark technique for the placement of central venous catheters in the emergency department. Acad Emerg Med. 2002;9:800–5.PubMedCrossRef Miller AH, Roth BA, Mills TJ, et al. Ultrasound guidance versus the landmark technique for the placement of central venous catheters in the emergency department. Acad Emerg Med. 2002;9:800–5.PubMedCrossRef
5.
go back to reference Shiloh AL, Savel RH, Paulin LM, et al. Ultrasound- guided catheterization of the radial artery: a systematic review and meta-analysis of randomized controlled trials. Chest. 2011;139:524–9.PubMedCrossRef Shiloh AL, Savel RH, Paulin LM, et al. Ultrasound- guided catheterization of the radial artery: a systematic review and meta-analysis of randomized controlled trials. Chest. 2011;139:524–9.PubMedCrossRef
6.
go back to reference Shiver S, Blaivas M, Lyon M. A prospective comparison of ultrasound-guided and blindly placed radial arterial catheters. Acad Emerg Med. 2006;13(12):1275–9.PubMedCrossRef Shiver S, Blaivas M, Lyon M. A prospective comparison of ultrasound-guided and blindly placed radial arterial catheters. Acad Emerg Med. 2006;13(12):1275–9.PubMedCrossRef
7.
go back to reference Blaivas M, Brannam L, Fernandez E. Short- axis versus long-axis approaches for teaching ultrasound- guided vascular access on a new inanimate model. Acad Emerg Med. 2003;10:1307–11.PubMedCrossRef Blaivas M, Brannam L, Fernandez E. Short- axis versus long-axis approaches for teaching ultrasound- guided vascular access on a new inanimate model. Acad Emerg Med. 2003;10:1307–11.PubMedCrossRef
8.
go back to reference Stone MB, Moon C, Sutijono D, Blaivas M. Needle tip visualization during ultrasound-guided vascular access: short-axis vs long-axis approach. Am J Emerg Med. 2010;28:343–7.PubMedCrossRef Stone MB, Moon C, Sutijono D, Blaivas M. Needle tip visualization during ultrasound-guided vascular access: short-axis vs long-axis approach. Am J Emerg Med. 2010;28:343–7.PubMedCrossRef
9.
go back to reference Edanaga M, Mimura M, Azumaguchi T, et al. Comparison of ultrasound-guided and blindly placed radial artery catheterization. Masui. 2012;61:221–4.PubMed Edanaga M, Mimura M, Azumaguchi T, et al. Comparison of ultrasound-guided and blindly placed radial artery catheterization. Masui. 2012;61:221–4.PubMed
10.
go back to reference Moon CH, Blehar D, Shear MA, et al. Incidence of posterior vessel wall puncture during ultrasound-guided vessel cannulation in a simulated model. Acad Emerg Med. 2010;17:1138–41.PubMedCrossRef Moon CH, Blehar D, Shear MA, et al. Incidence of posterior vessel wall puncture during ultrasound-guided vessel cannulation in a simulated model. Acad Emerg Med. 2010;17:1138–41.PubMedCrossRef
11.
go back to reference Chittoodan S, Breen D, O’Donnell BD, et al. Long versus short axis ultrasound guided approach for internal jugular vein cannulation: a prospective randomized controlled trial. Med Ultrasound. 2011;13:21–5. Chittoodan S, Breen D, O’Donnell BD, et al. Long versus short axis ultrasound guided approach for internal jugular vein cannulation: a prospective randomized controlled trial. Med Ultrasound. 2011;13:21–5.
12.
go back to reference Carmona Monge FJ, Martínez Lareo M, Núñez Reiz A. Ultrasound guided radial artery cannulation: procedure description and literature review. Enferm Intensiva. 2011;22:144–9.PubMedCrossRef Carmona Monge FJ, Martínez Lareo M, Núñez Reiz A. Ultrasound guided radial artery cannulation: procedure description and literature review. Enferm Intensiva. 2011;22:144–9.PubMedCrossRef
13.
go back to reference Sandhu NS. Use of ultrasonography as a rescue technique for failed radial artery cannulation. J Clin Anesth. 2004;18:138–41.CrossRef Sandhu NS. Use of ultrasonography as a rescue technique for failed radial artery cannulation. J Clin Anesth. 2004;18:138–41.CrossRef
14.
go back to reference Nifong TP, Mc Devitt TJ. The effect of catheter to vein ratio on blood flow rates in a simulated model of peripherally inserted central venous catheter. Chest. 2011;140:48–53.PubMedCrossRef Nifong TP, Mc Devitt TJ. The effect of catheter to vein ratio on blood flow rates in a simulated model of peripherally inserted central venous catheter. Chest. 2011;140:48–53.PubMedCrossRef
Metadata
Title
Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches?
Authors
Derya Berk
Yavuz Gurkan
Alparslan Kus
Halim Ulugol
Mine Solak
Kamil Toker
Publication date
01-06-2013
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 3/2013
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-013-9437-6

Other articles of this Issue 3/2013

Journal of Clinical Monitoring and Computing 3/2013 Go to the issue