Skip to main content
Top
Published in: International Ophthalmology 7/2020

01-07-2020 | Original Paper

Effect of corneal marking features on toric intraocular lens alignment

Author: Hasan Aytogan

Published in: International Ophthalmology | Issue 7/2020

Login to get access

Abstract

Purpose

The purpose of this study was to investigate the relation of the corneal ink mark size, shape, and location with the corneal perimeter in terms of the corresponding corneal axis.

Material and methods

This study was designed both prospective experimental and literature search. Contact lenses were used to demonstrate the spreading effect of the surgical ink mark. Open-access published corneal images with corneal ink marks were reviewed. Mark size and perimeter of both contact lenses and corneal images were performed in Image J software.

Results

Twenty contact lenses and 15 corneal images with 32 corneal marks, which were obtained from the literature, were included in the study. Mean degree corresponding to the ink size for the group 1 was 8.3° ± 1.2° (range 5.5–10.3), for group 2 was 11° ± 1.1° (range 8–12), for group 3 was 4.2° ± 0.7° (range 3.2–5.5), for group 4 was 4.2° ± 0.7° (range 3.2–5.5), and for group 5 was 6.3° ± 2.5° (range 2–11.5).

Discussion

Theoretically, it is wise to target further located ink mark from central cornea based on the 360/2π × (r2 − r1)/(r1 × r2) × M formula. It has been experimentally shown that the smaller corneal perimeter and closer mark to the central cornea may lead the more significant deviation from the targeted axis. Preoperative manual corneal marking may be more responsible for residual astigmatism than it is thought.
Literature
1.
go back to reference Hoffmann PC, Hütz WW (2010) Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes. J Cataract Refract Surg 36:1479–1485CrossRef Hoffmann PC, Hütz WW (2010) Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes. J Cataract Refract Surg 36:1479–1485CrossRef
3.
go back to reference Mohammadi M, Naderan M, Pahlevani R, Jahanrad A (2016) Prevalence of corneal astigmatism before cataract surgery. Int Ophthalmol 36:807–817CrossRef Mohammadi M, Naderan M, Pahlevani R, Jahanrad A (2016) Prevalence of corneal astigmatism before cataract surgery. Int Ophthalmol 36:807–817CrossRef
4.
go back to reference Lane SS, Ernest P, Miller KM, Hileman KS, Harris B, Waycaster CR (2009) Comparison of clinical and patient-reported outcomes with bilateral AcrySof toric or spherical control intraocular lenses. J Refract Surg 25:899–901CrossRef Lane SS, Ernest P, Miller KM, Hileman KS, Harris B, Waycaster CR (2009) Comparison of clinical and patient-reported outcomes with bilateral AcrySof toric or spherical control intraocular lenses. J Refract Surg 25:899–901CrossRef
6.
go back to reference Carey PJ, Leccisotti A, McGilligan VE, Goodall EA, Moore CBT (2010) Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation. J Cataract Refract Surg 36:222–229CrossRef Carey PJ, Leccisotti A, McGilligan VE, Goodall EA, Moore CBT (2010) Assessment of toric intraocular lens alignment by a refractive power/corneal analyzer system and slitlamp observation. J Cataract Refract Surg 36:222–229CrossRef
7.
go back to reference Visser N, Berendschot TTJM, Bauer NJC, Jurich J, Kersting O, Nuijts RMMA (2011) Accuracy of toric intraocular lens implantation in cataract and refractive surgery. J Cataract Refract Surg 37:1394–1402CrossRef Visser N, Berendschot TTJM, Bauer NJC, Jurich J, Kersting O, Nuijts RMMA (2011) Accuracy of toric intraocular lens implantation in cataract and refractive surgery. J Cataract Refract Surg 37:1394–1402CrossRef
8.
go back to reference Grohlich M, Miháltz K, Lasta M et al (2017) Evaluation of postoperative astigmatism correction and postoperative rotational stability of two toric intraocular lenses. Klin Monbl Augenheilkd 234:796–804CrossRef Grohlich M, Miháltz K, Lasta M et al (2017) Evaluation of postoperative astigmatism correction and postoperative rotational stability of two toric intraocular lenses. Klin Monbl Augenheilkd 234:796–804CrossRef
12.
go back to reference Roumeliotis G, Hutnik C (2012) A simple reproducible and cost effective axis marking system for toric lens implantation. J Refract Surg 28:12–13CrossRef Roumeliotis G, Hutnik C (2012) A simple reproducible and cost effective axis marking system for toric lens implantation. J Refract Surg 28:12–13CrossRef
13.
go back to reference Popp N, Hirnschall N, Maedel S et al (2012) Evaluation of 4 corneal astigmatic marking methods. J Cataract Refract Surg 38:2094–2099CrossRef Popp N, Hirnschall N, Maedel S et al (2012) Evaluation of 4 corneal astigmatic marking methods. J Cataract Refract Surg 38:2094–2099CrossRef
14.
go back to reference Igarashi A, Kamiya K, Shimizu K (2013) Clinical evaluation of accuracy of horizontal meridian limbal marking. Optom Vis Sci 90:540–545CrossRef Igarashi A, Kamiya K, Shimizu K (2013) Clinical evaluation of accuracy of horizontal meridian limbal marking. Optom Vis Sci 90:540–545CrossRef
15.
go back to reference Lin HY, Fang YT, Chuang YJ, Karlin JN, Chen HY, Lin SY, Lin PJ, Chen M (2017) A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian. Clin Ophthalmol 11:311–315CrossRef Lin HY, Fang YT, Chuang YJ, Karlin JN, Chen HY, Lin SY, Lin PJ, Chen M (2017) A comparison of three different corneal marking methods used to determine cyclotorsion in the horizontal meridian. Clin Ophthalmol 11:311–315CrossRef
16.
go back to reference Farooqui JH, Koul A, Dutta R, Shroff NM (2016) Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker. Int J Ophthalmol 9:703–706PubMedPubMedCentral Farooqui JH, Koul A, Dutta R, Shroff NM (2016) Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker. Int J Ophthalmol 9:703–706PubMedPubMedCentral
17.
go back to reference Hill W, Potvin R (2008) Monte Carlo simulation of expected outcomes with the Acrysof toric intraocular lens. BMC Ophthalmol 8:22CrossRef Hill W, Potvin R (2008) Monte Carlo simulation of expected outcomes with the Acrysof toric intraocular lens. BMC Ophthalmol 8:22CrossRef
18.
go back to reference Jordan A, Baum J (1980) Basic tear flow. Does it exist? Ophthalmology 87:920CrossRef Jordan A, Baum J (1980) Basic tear flow. Does it exist? Ophthalmology 87:920CrossRef
19.
go back to reference The definition and classification of dry eye disease: report of the definition and classification subcommittee of the international dry eye workshop (2007), vol 5, no 2, pp 75–92 The definition and classification of dry eye disease: report of the definition and classification subcommittee of the international dry eye workshop (2007), vol 5, no 2, pp 75–92
Metadata
Title
Effect of corneal marking features on toric intraocular lens alignment
Author
Hasan Aytogan
Publication date
01-07-2020
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 7/2020
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-020-01333-4

Other articles of this Issue 7/2020

International Ophthalmology 7/2020 Go to the issue