Skip to main content
Top
Published in: International Ophthalmology 9/2019

01-09-2019 | Original Paper

A practical and easy surgical technique for recovery of an incarcerated haptic

Authors: Yusuf Koçluk, Emine Alyamaç Sukgen, Burcu Kasım, Oğuzhan Saygılı

Published in: International Ophthalmology | Issue 9/2019

Login to get access

Abstract

Purpose

To present a surgical intervention for a posterior haptic trapped between the cartridge and plunger during intraocular lens (IOL) implantation.

Materials and methods

Posterior haptic incarceration was detected in 36 cases during implantation of a one-piece foldable IOL during cataract surgery with phacoemulsification. In 11 of the patients (Group 1), recovery was achieved by forcibly pulling out the incarcerated posterior haptic. In 25 cases (Group 2), the haptic was recovered by using an MVR knife to cut the cartridge tip from the bottom up parallel to the trapped haptic.

Results

In Group 1, tears were seen on the incarcerated haptic in all cases (100%). In Group 2, the procedure was successful in all 25 cases and there was no accidental cutting of the haptic. In all cases, the surgeries were completed with the recovered IOL in Group 2.

Conclusions

Posterior haptic incarceration in cataract surgery can be solved by the simple and easy method of cutting the cartridge tip from the bottom upwards and releasing the haptic.
Appendix
Available only for authorised users
Literature
1.
go back to reference Ouchi M (2012) Effect of intraocular lens insertion speed on surgical wound structure. J Cataract Refract Surg 38:1771–1776CrossRef Ouchi M (2012) Effect of intraocular lens insertion speed on surgical wound structure. J Cataract Refract Surg 38:1771–1776CrossRef
2.
go back to reference Milazzo S, Turut P, Blin H (1996) Alterations to the AcrySof intraocular lens during folding. J Cataract Refract Surg 22:1351–1354CrossRefPubMed Milazzo S, Turut P, Blin H (1996) Alterations to the AcrySof intraocular lens during folding. J Cataract Refract Surg 22:1351–1354CrossRefPubMed
3.
go back to reference Vrabec MP, Syverud JC, Burgess CJ (1996) Forceps-induced scratching of a foldable acrylic intraocular lens [letter]. Arch Ophthalmol 114:777CrossRefPubMed Vrabec MP, Syverud JC, Burgess CJ (1996) Forceps-induced scratching of a foldable acrylic intraocular lens [letter]. Arch Ophthalmol 114:777CrossRefPubMed
4.
go back to reference Pfister DR (1995) Stress fractures after folding an acrylic intraocular lens. Am J Ophthalmol 121:572–574CrossRef Pfister DR (1995) Stress fractures after folding an acrylic intraocular lens. Am J Ophthalmol 121:572–574CrossRef
5.
go back to reference Carlson KH, Johnson DW (1995) Cracking of acrylic intraocular lenses during capsular bag insertion. Ophthalmic Surg Lasers 26:572–573PubMed Carlson KH, Johnson DW (1995) Cracking of acrylic intraocular lenses during capsular bag insertion. Ophthalmic Surg Lasers 26:572–573PubMed
6.
go back to reference Kleinmann G, Apple DJ (2007) Evaluation of a new soft tipped injector for the implantation of foldable intraocular lenses. Br J Ophthalmol 9:1070–1072CrossRef Kleinmann G, Apple DJ (2007) Evaluation of a new soft tipped injector for the implantation of foldable intraocular lenses. Br J Ophthalmol 9:1070–1072CrossRef
7.
8.
go back to reference Chai F, Ma B, Yang XG, Li J, Chu MF (2017) A pilot study of intraocular lens explantation in 69 eyes in Chinese patients. Int J Ophthalmol 10:579PubMedPubMedCentral Chai F, Ma B, Yang XG, Li J, Chu MF (2017) A pilot study of intraocular lens explantation in 69 eyes in Chinese patients. Int J Ophthalmol 10:579PubMedPubMedCentral
9.
go back to reference Oltulu R, Erşan İ, Şatırtav G, Donbaloglu M, Kerimoğlu H, Özkağnıcı A (2015) Intraocular lens explantation or exchange: indications, postoperative interventions, and outcomes. Arq Bras Oftalmol 78:154–157PubMed Oltulu R, Erşan İ, Şatırtav G, Donbaloglu M, Kerimoğlu H, Özkağnıcı A (2015) Intraocular lens explantation or exchange: indications, postoperative interventions, and outcomes. Arq Bras Oftalmol 78:154–157PubMed
10.
go back to reference Fernández-Buenaga R, Alio JL, Pérez-Ardoy AL, Larrosa-Quesada A, Pinilla-Cortés L, Barraquer R, Alio JL 2nd, Muñoz-Negrete FJ (2013) Late in-the-bag intraocular lens dislocation requiring explantation: risk factors and outcomes. Eye 27:795–802CrossRefPubMedPubMedCentral Fernández-Buenaga R, Alio JL, Pérez-Ardoy AL, Larrosa-Quesada A, Pinilla-Cortés L, Barraquer R, Alio JL 2nd, Muñoz-Negrete FJ (2013) Late in-the-bag intraocular lens dislocation requiring explantation: risk factors and outcomes. Eye 27:795–802CrossRefPubMedPubMedCentral
11.
12.
go back to reference Kohnen T, Magdowski G, Koch DD (1996) Scanning electron microscopic analysis of foldable acrylic and hydrogel intraocular lenses. J Cataract Refract Surg 22:1342–1350CrossRefPubMed Kohnen T, Magdowski G, Koch DD (1996) Scanning electron microscopic analysis of foldable acrylic and hydrogel intraocular lenses. J Cataract Refract Surg 22:1342–1350CrossRefPubMed
Metadata
Title
A practical and easy surgical technique for recovery of an incarcerated haptic
Authors
Yusuf Koçluk
Emine Alyamaç Sukgen
Burcu Kasım
Oğuzhan Saygılı
Publication date
01-09-2019
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 9/2019
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-018-1047-3

Other articles of this Issue 9/2019

International Ophthalmology 9/2019 Go to the issue