Skip to main content
Top
Published in: International Ophthalmology 3/2018

01-06-2018 | Original Paper

Self-made cryopreservative fibrin glue applied in pterygium surgery: a novel practical technique

Authors: Jing-Wen Gong, Jun-Hao Chen, Ting Shen, Jin Jiang

Published in: International Ophthalmology | Issue 3/2018

Login to get access

Abstract

Purpose

To introduce a novel practical technique of self-made cryopreservative fibrin glue (SMC) applied in pterygium surgery and to assess its safety and efficacy.

Methods

Forty-eight eyes of 48 patients with nasal primary pterygium were enrolled. The patients were equally assigned to 6 groups. Self-made fibrin glue was subpackaged and, respectively, cryopreserved for 3, 7, 15 days and 1, 2 and 3 months. At each time point, the asepsis of SMC was confirmed by bacterial culture and colony counting. In each group, corresponding SMC was applied to fix the autograft after the pterygium was removed (e.g., SMC 3d for group 1 and SMC 3m for group 6). All the patients were followed up postoperatively on days 1, 3, 7 and 14 and then at months 1, 3, 6. The main outcome measures included fixation success rate within two tries, postoperative discomfort, recurrence rate and complications.

Results

No colony growth was observed in all the fibrinogen and thrombin tubes sent. Five patients needed a second try with respective SMC during the autograft fixation, and there were no significant differences in SMC use times among the groups (P = 0.885). There were no significant differences in postoperative discomfort (day 1, 3, 7; P = 0.651, P = 0.269, P = 0.180, respectively) among the groups. By the end of 6-m follow-up, no infections and severe complications were observed in any group. The total recurrence rate was 3/48 (6%), and there were no significant differences in recurrences among the groups (P = 1.000).

Conclusion

SMC is safe and effective for autograft fixation in pterygium surgery. This new practical technique will benefit the patients and surgeons in developing and underdeveloped country.
Literature
2.
go back to reference Uy HS, Reyes JM, Flores JD et al (2005) Comparison of fibrin glue and sutures for attaching conjunctival autografts after pterygiumexcision. Ophthalmology 112:667–671CrossRefPubMed Uy HS, Reyes JM, Flores JD et al (2005) Comparison of fibrin glue and sutures for attaching conjunctival autografts after pterygiumexcision. Ophthalmology 112:667–671CrossRefPubMed
3.
go back to reference Bahar I, Weinberger D, Dan G et al (2006) Pterygium surgery: fibrin glue versus Vicryl sutures for conjunctival closure. Cornea 25:1168–1172CrossRefPubMed Bahar I, Weinberger D, Dan G et al (2006) Pterygium surgery: fibrin glue versus Vicryl sutures for conjunctival closure. Cornea 25:1168–1172CrossRefPubMed
4.
go back to reference Jiang J, Yang Y, Zhang M et al (2008) Comparison of fibrin sealant and sutures for conjunctival autograft fixation in pterygium surgery: one-year follow-up. Ophthalmologica 222:105–111CrossRefPubMed Jiang J, Yang Y, Zhang M et al (2008) Comparison of fibrin sealant and sutures for conjunctival autograft fixation in pterygium surgery: one-year follow-up. Ophthalmologica 222:105–111CrossRefPubMed
5.
go back to reference Hall RC, Logan AJ, Wells AP (2009) Comparison of fibrin glue with sutures for pterygium excision surgery with conjunctival autografts. Clin Exp Ophthalmol 37:584–589CrossRefPubMed Hall RC, Logan AJ, Wells AP (2009) Comparison of fibrin glue with sutures for pterygium excision surgery with conjunctival autografts. Clin Exp Ophthalmol 37:584–589CrossRefPubMed
6.
go back to reference Cha DM, Kim KH, Choi HJ et al (2012) A comparative study of the effect of fibrin glue versus sutures on clinical outcome in patient undergoing pterygium excision and conjunctival autografts. Korean J Ophthalmol 26:407–413CrossRefPubMedPubMedCentral Cha DM, Kim KH, Choi HJ et al (2012) A comparative study of the effect of fibrin glue versus sutures on clinical outcome in patient undergoing pterygium excision and conjunctival autografts. Korean J Ophthalmol 26:407–413CrossRefPubMedPubMedCentral
7.
go back to reference Koranyi G, Artzén D, Wijk T (2013) Learning curve in the cut and paste method for surgery of primary pterygium. Acta Ophthalmol 91:463–468CrossRefPubMed Koranyi G, Artzén D, Wijk T (2013) Learning curve in the cut and paste method for surgery of primary pterygium. Acta Ophthalmol 91:463–468CrossRefPubMed
8.
go back to reference Cagatay HH, Gokce G, Ekinci M et al (2014) Long-term comparison of fibrin tissue glue and vicryl suture in conjunctival autografting for pterygium surgery. Postgrad Med 126:97–103CrossRefPubMed Cagatay HH, Gokce G, Ekinci M et al (2014) Long-term comparison of fibrin tissue glue and vicryl suture in conjunctival autografting for pterygium surgery. Postgrad Med 126:97–103CrossRefPubMed
9.
go back to reference Jiang J, Gong J, Li W et al (2015) Comparison of intra-operative 0.02% mitomycin C and sutureless limbal conjunctival autograft fixation in pterygium surgery: five-year follow-up. Acta Ophthalmol 93:e568–e572CrossRefPubMed Jiang J, Gong J, Li W et al (2015) Comparison of intra-operative 0.02% mitomycin C and sutureless limbal conjunctival autograft fixation in pterygium surgery: five-year follow-up. Acta Ophthalmol 93:e568–e572CrossRefPubMed
10.
go back to reference Tan DT, Chee SP, Dear KB, Lim AS (1997) Effect of pterygium morphology on pterygium recurrence in a controlled trial comparing conjunctival autografting with bare sclera excision. Arch Ophthalmol 115(10):1235–1240CrossRefPubMed Tan DT, Chee SP, Dear KB, Lim AS (1997) Effect of pterygium morphology on pterygium recurrence in a controlled trial comparing conjunctival autografting with bare sclera excision. Arch Ophthalmol 115(10):1235–1240CrossRefPubMed
11.
go back to reference Romano V, Cruciani M, Conti L, Fontana L (2016) Fibrin glue versus sutures for conjunctival autografting in primary pterygium surgery. Cochrane Database Syst Rev 12:CD011308PubMed Romano V, Cruciani M, Conti L, Fontana L (2016) Fibrin glue versus sutures for conjunctival autografting in primary pterygium surgery. Cochrane Database Syst Rev 12:CD011308PubMed
12.
go back to reference Koranyi G, Seregard S, Kopp ED (2005) The cut and-paste method for primary pterygium surgery: long-term follow-up. Acta Ophthalmol Scand 83:298–301CrossRefPubMed Koranyi G, Seregard S, Kopp ED (2005) The cut and-paste method for primary pterygium surgery: long-term follow-up. Acta Ophthalmol Scand 83:298–301CrossRefPubMed
13.
go back to reference Marticorena J, Rodríguez-Ares MT, Touriño R et al (2006) Pterygium surgery: conjunctival autograft using a fibrin adhesive. Cornea 25:34–36CrossRefPubMed Marticorena J, Rodríguez-Ares MT, Touriño R et al (2006) Pterygium surgery: conjunctival autograft using a fibrin adhesive. Cornea 25:34–36CrossRefPubMed
14.
go back to reference Pfister RR, Sommers CI (2005) Fibrin sealant in corneal stem cell transplantation. Cornea 24:593–598CrossRefPubMed Pfister RR, Sommers CI (2005) Fibrin sealant in corneal stem cell transplantation. Cornea 24:593–598CrossRefPubMed
15.
go back to reference Kurian A, Reghunadhan I, Nair KG (2015) Autologous blood versus fibrin glue for conjunctival autograft adherence in sutureless pterygium surgery: a randomised controlled trial. Br J Ophthalmol 99(4):464–470CrossRefPubMed Kurian A, Reghunadhan I, Nair KG (2015) Autologous blood versus fibrin glue for conjunctival autograft adherence in sutureless pterygium surgery: a randomised controlled trial. Br J Ophthalmol 99(4):464–470CrossRefPubMed
16.
go back to reference Nadarajah G, Ratnalingam VH, Mohd Isa H (2017) Autologous blood versus fibrin glue in pterygium excision with conjunctival autograft surgery. Cornea 36(4):452–456CrossRefPubMed Nadarajah G, Ratnalingam VH, Mohd Isa H (2017) Autologous blood versus fibrin glue in pterygium excision with conjunctival autograft surgery. Cornea 36(4):452–456CrossRefPubMed
17.
go back to reference Boucher S, Conlon R, Teja S et al (2015) Fibrin glue versus autologous blood for conjunctival autograft fixation in pterygium surgery. Can J Ophthalmol 50(4):269–272CrossRefPubMed Boucher S, Conlon R, Teja S et al (2015) Fibrin glue versus autologous blood for conjunctival autograft fixation in pterygium surgery. Can J Ophthalmol 50(4):269–272CrossRefPubMed
18.
go back to reference Choudhury S, Dutta J, Mukhopadhyay S et al (2014) Comparison of autologous in situ blood coagulum versus sutures for conjunctival autografting after pterygium excision. Int Ophthalmol 34(1):41–48CrossRefPubMed Choudhury S, Dutta J, Mukhopadhyay S et al (2014) Comparison of autologous in situ blood coagulum versus sutures for conjunctival autografting after pterygium excision. Int Ophthalmol 34(1):41–48CrossRefPubMed
19.
go back to reference Morita Y, Nishii O, Kido M et al (2000) Parvovirus infection after laparoscopic hysterectomy using fibrin glue hemostasis. Obstet Gynecol 95(6 Pt 2):1026PubMed Morita Y, Nishii O, Kido M et al (2000) Parvovirus infection after laparoscopic hysterectomy using fibrin glue hemostasis. Obstet Gynecol 95(6 Pt 2):1026PubMed
20.
go back to reference Hino M, Ishiko O, Honda KI et al (2000) Transmission of symptomatic parvovirus B19 infection by fibrin sealant used during surgery. Br J Haematol 108(1):194–195CrossRefPubMed Hino M, Ishiko O, Honda KI et al (2000) Transmission of symptomatic parvovirus B19 infection by fibrin sealant used during surgery. Br J Haematol 108(1):194–195CrossRefPubMed
Metadata
Title
Self-made cryopreservative fibrin glue applied in pterygium surgery: a novel practical technique
Authors
Jing-Wen Gong
Jun-Hao Chen
Ting Shen
Jin Jiang
Publication date
01-06-2018
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 3/2018
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-017-0629-9

Other articles of this Issue 3/2018

International Ophthalmology 3/2018 Go to the issue