Skip to main content
Top
Published in: International Ophthalmology 4/2018

01-08-2018 | Original Paper

A sample predictive model for intraocular pressure following laser in situ keratomileusis for myopia and an “intraocular pressure constant”

Authors: Ayse Ebru Bahadir Kilavuzoglu, Tahir Kansu Bozkurt, Cemile Banu Cosar, Asım Bozkurt Sener

Published in: International Ophthalmology | Issue 4/2018

Login to get access

Abstract

Purpose

To describe a sample predictive model for intraocular pressure (IOP) following laser in situ keratomileusis (LASIK) for myopia and an IOP constant.

Methods

The records of patients that underwent LASIK for myopia and myopic astigmatism via WaveLight Allegretto Wave Eye-Q 400 Hz excimer laser and Hansatome XP microkeratome were retrospectively reviewed. Patients with no systemic or ocular disease other than myopia or myopic astigmatism were included in the study. Preoperative and postoperative month 1 data and intraoperative data were used to build the predictive model for IOP after LASIK. The IOP constant was calculated by subtracting the predicted IOP from preoperative IOP. The paired samples t test, Pearson’s correlation analysis, curve estimation analysis, and linear regression analysis were used to evaluate the study data.

Results

The study included 425 eyes in 214 patients with a mean age of 32 ± 7.8 years. Mean spherical equivalent of the attempted correction (SE-ac) was −3.7 ± 1.7 diopters. Mean post-LASIK decrease in IOP was 4.6 ± 2.3 mmHg. The difference between preoperative and postoperative IOP was statistically significant (P < 0.001). SE-ac, preoperative IOP, and central corneal thickness had highly significant effects on postoperative IOP, based on linear regression analysis (P < 0.001 and R 2 = 0.043, P < 0.001 and R 2 = 0.370, and P < 0.001 and R 2 = 0.132, respectively). Regression model was created (F = 127.733, P < 0.001), and the adjusted R 2 value was 0.548.

Conclusions

Evaluation of IOP after LASIK is important in myopic patients. The present study described a practical formula for predicting the true IOP with the aid of an IOP constant value in myopic eyes following LASIK.
Literature
2.
go back to reference Kohlhaas M, Spoerl E, Boehm AG, Pollack K (2006) A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism. J Refract Surg 22:263–267PubMed Kohlhaas M, Spoerl E, Boehm AG, Pollack K (2006) A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism. J Refract Surg 22:263–267PubMed
3.
go back to reference Yang CC, Wang IJ, Chang YC, Lin LL, Chen TH (2006) A predictive model for postoperative intraocular pressure among patients undergoing laser in situ keratomileusis (LASIK). Am J Ophthalmol 141:530–536CrossRefPubMed Yang CC, Wang IJ, Chang YC, Lin LL, Chen TH (2006) A predictive model for postoperative intraocular pressure among patients undergoing laser in situ keratomileusis (LASIK). Am J Ophthalmol 141:530–536CrossRefPubMed
4.
go back to reference Kucuksumer Y, Sivrikaya H, Bayraktar S, Yilmaz OF (2001) Effects of ocular parameters on intraocular pressure changes after laser in situ keratomileusis. Turk J Ophthalmol 31:139–145 Kucuksumer Y, Sivrikaya H, Bayraktar S, Yilmaz OF (2001) Effects of ocular parameters on intraocular pressure changes after laser in situ keratomileusis. Turk J Ophthalmol 31:139–145
5.
go back to reference Sentut S, Yilmaz S, Maden A (2008) Comparison of intraocular pressure measurements from peripheral and central cornea after LASIK procedure. J Glaucoma Cataract 3:186–189 Sentut S, Yilmaz S, Maden A (2008) Comparison of intraocular pressure measurements from peripheral and central cornea after LASIK procedure. J Glaucoma Cataract 3:186–189
7.
go back to reference Cheng AC, Fan D, Tang E, Lam DS (2006) Effect of corneal curvature and corneal thickness on the assessment of intraocular pressure using noncontact tonometry in patients after myopic LASIK surgery. Cornea 25:26–28CrossRefPubMed Cheng AC, Fan D, Tang E, Lam DS (2006) Effect of corneal curvature and corneal thickness on the assessment of intraocular pressure using noncontact tonometry in patients after myopic LASIK surgery. Cornea 25:26–28CrossRefPubMed
8.
go back to reference Chang DH, Stulting RD (2005) Change in intraocular pressure measurements after LASIK the effect of the refractive correction and the lamellar flap. Ophthalmology 112:1009–1016CrossRefPubMed Chang DH, Stulting RD (2005) Change in intraocular pressure measurements after LASIK the effect of the refractive correction and the lamellar flap. Ophthalmology 112:1009–1016CrossRefPubMed
9.
go back to reference Diggle PJ, Liang KY, Zeger SL (1994) Analysis of longitudinal data. Oxford University Press, New York Diggle PJ, Liang KY, Zeger SL (1994) Analysis of longitudinal data. Oxford University Press, New York
10.
go back to reference Mitchell P, Hourihan F, Sandbach J, Wang JJ (1999) The relationship between glaucoma and myopia: the Blue Mountains Eye Study. Ophthalmology 106:2010–2015CrossRefPubMed Mitchell P, Hourihan F, Sandbach J, Wang JJ (1999) The relationship between glaucoma and myopia: the Blue Mountains Eye Study. Ophthalmology 106:2010–2015CrossRefPubMed
11.
go back to reference Emara B, Probst LE, Tingey DP, Kennedy DW, Willms LJ, Machat J (1998) Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis. J Cataract Refract Surg 24:1320–1325CrossRefPubMed Emara B, Probst LE, Tingey DP, Kennedy DW, Willms LJ, Machat J (1998) Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusis. J Cataract Refract Surg 24:1320–1325CrossRefPubMed
12.
go back to reference Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, de Jong PT (1997) Distribution of central corneal thickness and its association with intraocular pressure: the Rotterdam study. Am J Ophthalmol 123:767–772CrossRefPubMed Wolfs RC, Klaver CC, Vingerling JR, Grobbee DE, Hofman A, de Jong PT (1997) Distribution of central corneal thickness and its association with intraocular pressure: the Rotterdam study. Am J Ophthalmol 123:767–772CrossRefPubMed
14.
go back to reference Sakalar YB, Keklikci U, Balsak S, Dogan E, Unlu K (2010) Comparison of different methods for measurement of intraocular pressure and evaluation of effect of central corneal thickness on measurement results. Turk J Ophthalmol 40:156–159CrossRef Sakalar YB, Keklikci U, Balsak S, Dogan E, Unlu K (2010) Comparison of different methods for measurement of intraocular pressure and evaluation of effect of central corneal thickness on measurement results. Turk J Ophthalmol 40:156–159CrossRef
15.
go back to reference Mardelli PG, Piebenga LW, Whitacre MM, Siegmund KD (1997) The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer. Ophthalmology 104:945–948CrossRefPubMed Mardelli PG, Piebenga LW, Whitacre MM, Siegmund KD (1997) The effect of excimer laser photorefractive keratectomy on intraocular pressure measurements using the Goldmann applanation tonometer. Ophthalmology 104:945–948CrossRefPubMed
16.
go back to reference Gimeno JA, Munoz LA, Valenzuela LA, Molto FJ, Rahhal MS (2000) Influence of refraction on tonometric readings after photorefractive keratectomy and laser assisted in situ keratomileusis. Cornea 19:512–516CrossRefPubMed Gimeno JA, Munoz LA, Valenzuela LA, Molto FJ, Rahhal MS (2000) Influence of refraction on tonometric readings after photorefractive keratectomy and laser assisted in situ keratomileusis. Cornea 19:512–516CrossRefPubMed
17.
go back to reference Park HJ, Uhm KB, Hong C (2001) Reduction in intraocular pressure after laser in situ keratomileusis. J Cataract Refract Surg 27:303–309CrossRefPubMed Park HJ, Uhm KB, Hong C (2001) Reduction in intraocular pressure after laser in situ keratomileusis. J Cataract Refract Surg 27:303–309CrossRefPubMed
18.
go back to reference El Danasoury MA, El Maghraby A, Coorpender SJ (2001) Change in intraocular pressure in myopic eyes measured with contact and non-contact tonometers after laser in situ keratomileusis. J Refract Surg 17:97–104PubMed El Danasoury MA, El Maghraby A, Coorpender SJ (2001) Change in intraocular pressure in myopic eyes measured with contact and non-contact tonometers after laser in situ keratomileusis. J Refract Surg 17:97–104PubMed
19.
go back to reference Duch S, Serra A, Castanera J, Abos R, Quintana M (2001) Tonometry after laser in situ keratomileusis treatment. J Glaucoma 10:261–265CrossRefPubMed Duch S, Serra A, Castanera J, Abos R, Quintana M (2001) Tonometry after laser in situ keratomileusis treatment. J Glaucoma 10:261–265CrossRefPubMed
20.
go back to reference Chihara E, Takahashi H, Okazaki K, Park M, Tanito M (2005) The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia. Br J Ophthalmol 89:160–164CrossRefPubMedPubMedCentral Chihara E, Takahashi H, Okazaki K, Park M, Tanito M (2005) The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia. Br J Ophthalmol 89:160–164CrossRefPubMedPubMedCentral
21.
go back to reference Recep OF, Cagil N, Hasiripi H (2000) Correlation between intraocular pressure and corneal stromal thickness after laser in situ keratomileusis. J Cataract Refract Surg 26:1480–1483CrossRefPubMed Recep OF, Cagil N, Hasiripi H (2000) Correlation between intraocular pressure and corneal stromal thickness after laser in situ keratomileusis. J Cataract Refract Surg 26:1480–1483CrossRefPubMed
22.
go back to reference De Moraes CGV, Prata TS, Liebmann J, Ritch R (2008) Modalities of tonometry and their accuracy with respect to corneal thickness and irregularities. J Optom 1:43–49CrossRefPubMedCentral De Moraes CGV, Prata TS, Liebmann J, Ritch R (2008) Modalities of tonometry and their accuracy with respect to corneal thickness and irregularities. J Optom 1:43–49CrossRefPubMedCentral
Metadata
Title
A sample predictive model for intraocular pressure following laser in situ keratomileusis for myopia and an “intraocular pressure constant”
Authors
Ayse Ebru Bahadir Kilavuzoglu
Tahir Kansu Bozkurt
Cemile Banu Cosar
Asım Bozkurt Sener
Publication date
01-08-2018
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 4/2018
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-017-0617-0

Other articles of this Issue 4/2018

International Ophthalmology 4/2018 Go to the issue