Skip to main content
Top
Published in: International Ophthalmology 1/2018

01-02-2018 | Original Paper

Comparison of graft survival following penetrating keratoplasty and Descemet’s stripping endothelial keratoplasty in eyes with a glaucoma drainage device

Authors: Shawn M. Iverson, Oriel Spierer, George C. Papachristou, William J. Feuer, Wei Shi, David S. Greenfield, Terrence P. O’Brien

Published in: International Ophthalmology | Issue 1/2018

Login to get access

Abstract

Purpose

To compare corneal graft survival rates after penetrating keratoplasty (PK) and Descemet’s stripping endothelial keratoplasty (DSEK) in patients with a glaucoma drainage device (GDD) or medically managed glaucoma.

Methods

A retrospective chart review was conducted on consecutive patients who underwent primary PK or primary DSEK. Inclusion criteria consisted of eyes with a diagnosis of glaucoma prior to corneal transplantation and a minimum of 6 months of follow-up. Graft failure was defined as an edematous cornea with failure to maintain deturgescence lasting beyond a period of 1 month of intense steroid therapy or vascularization and scarring resulting in irreversible loss of central graft clarity. Corneal graft survival was calculated using Kaplan–Meier survival analysis. Patients were divided into four groups: GDD-PK, GDD-DSEK, medical-PK and medical-DSEK.

Results

Fifty-six eyes of 56 patients were identified as meeting inclusion criteria. Among eyes with a GDD, there was no difference in the proportion of failures between PK grafts (48%) and DSEK grafts (50%) (p = 0.90). Failure occurred earlier in DSEK recipients compared to PK recipients, 5.82 ± 6.77 months versus 14.40 ± 7.70 months, respectively (p = 0.04). A Kaplan–Meier analysis did not identify a difference between the four groups with respect to graft failure (p = 0.52).

Conclusion

There is no significant difference in graft survival rates between medically and surgically treated glaucoma patients for either PK or DSEK grafts. In patients with GDD, graft failure occurs earlier in DSEK compared to PK.
Literature
1.
2.
go back to reference Price FW Jr, Price MO (2005) Descemet’s stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. J Refract Surg 21:339–345PubMed Price FW Jr, Price MO (2005) Descemet’s stripping with endothelial keratoplasty in 50 eyes: a refractive neutral corneal transplant. J Refract Surg 21:339–345PubMed
3.
go back to reference Anshu A, Price MO, Tan DTH, Price FW Jr (2012) Endothelial keratoplasty: a revolution in evolution. Surv Ophthalmol 57:236–252CrossRefPubMed Anshu A, Price MO, Tan DTH, Price FW Jr (2012) Endothelial keratoplasty: a revolution in evolution. Surv Ophthalmol 57:236–252CrossRefPubMed
5.
go back to reference Kosker M, Suri K, Duman F, Hammersmith KM, Nagra PK, Rapuano CJ (2013) Long-term outcomes of penetrating keratoplasty and Descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy: fellow eye comparison. Cornea 32:1083–1088CrossRefPubMed Kosker M, Suri K, Duman F, Hammersmith KM, Nagra PK, Rapuano CJ (2013) Long-term outcomes of penetrating keratoplasty and Descemet stripping endothelial keratoplasty for Fuchs endothelial dystrophy: fellow eye comparison. Cornea 32:1083–1088CrossRefPubMed
6.
go back to reference Price MO, Gorovoy M, Price FW Jr, Benetz BA, Menegay HJ, Lass JH (2013) Descemet’s stripping automated endothelial keratoplasty: three-year graft and endothelial cell survival compared with penetrating keratoplasty. Ophthalmology 120:246–251CrossRefPubMed Price MO, Gorovoy M, Price FW Jr, Benetz BA, Menegay HJ, Lass JH (2013) Descemet’s stripping automated endothelial keratoplasty: three-year graft and endothelial cell survival compared with penetrating keratoplasty. Ophthalmology 120:246–251CrossRefPubMed
7.
go back to reference Duman F, Kosker M, Suri K, Reddy JC, Ma JF, Hammersmith KM, Nagra PK, Rapuano CJ (2013) Indications and outcomes of corneal transplantation in geriatric patients. Am J Ophthalmol 156:600–607CrossRefPubMed Duman F, Kosker M, Suri K, Reddy JC, Ma JF, Hammersmith KM, Nagra PK, Rapuano CJ (2013) Indications and outcomes of corneal transplantation in geriatric patients. Am J Ophthalmol 156:600–607CrossRefPubMed
8.
go back to reference Anshu A, Price MO, Price FW (2012) Descemet’s stripping endothelial keratoplasty: long-term graft survival and risk factors for failure in eyes with preexisting glaucoma. Ophthalmology 119:1982–1987CrossRefPubMed Anshu A, Price MO, Price FW (2012) Descemet’s stripping endothelial keratoplasty: long-term graft survival and risk factors for failure in eyes with preexisting glaucoma. Ophthalmology 119:1982–1987CrossRefPubMed
9.
go back to reference Price MO, Fairchild KM, Price DA, Price FW Jr (2011) Descemet’s stripping endothelial keratoplasty five-year graft survival and endothelial cell loss. Ophthalmology 118:725–729CrossRefPubMed Price MO, Fairchild KM, Price DA, Price FW Jr (2011) Descemet’s stripping endothelial keratoplasty five-year graft survival and endothelial cell loss. Ophthalmology 118:725–729CrossRefPubMed
10.
go back to reference Price MO, Gorovoy M, Benetz BA, Price FW Jr, Menegay HJ, Debanne SM, Lass JH (2010) Descemet’s stripping automated endothelial keratoplasty outcomes compared with penetrating keratoplasty from the cornea donor study. Ophthalmology 117:438–444CrossRefPubMedPubMedCentral Price MO, Gorovoy M, Benetz BA, Price FW Jr, Menegay HJ, Debanne SM, Lass JH (2010) Descemet’s stripping automated endothelial keratoplasty outcomes compared with penetrating keratoplasty from the cornea donor study. Ophthalmology 117:438–444CrossRefPubMedPubMedCentral
11.
go back to reference Lee WB, Jacobs DS, Musch DC, Kaufman SC, Reinhart WJ, Shtein RM (2009) Descemet’s stripping endothelial keratoplasty: safety and outcomes: a report by the American Academy of Ophthalmology. Ophthalmology 116:1818–1830CrossRefPubMed Lee WB, Jacobs DS, Musch DC, Kaufman SC, Reinhart WJ, Shtein RM (2009) Descemet’s stripping endothelial keratoplasty: safety and outcomes: a report by the American Academy of Ophthalmology. Ophthalmology 116:1818–1830CrossRefPubMed
12.
go back to reference Allan BD, Terry MA, Price FW Jr, Price MO, Griffin NB, Claesson M (2007) Corneal transplant rejection rate and severity after endothelial keratoplasty. Cornea 26:1039–1042CrossRefPubMed Allan BD, Terry MA, Price FW Jr, Price MO, Griffin NB, Claesson M (2007) Corneal transplant rejection rate and severity after endothelial keratoplasty. Cornea 26:1039–1042CrossRefPubMed
13.
go back to reference Beckingsale P, Mavrikakis I, Al-Yousuf N, Mavrikakis E, Daya SM (2006) Penetrating keratoplasty: outcomes from a corneal unit compared to national data. Br J Ophthalmol 90:726–731CrossRef Beckingsale P, Mavrikakis I, Al-Yousuf N, Mavrikakis E, Daya SM (2006) Penetrating keratoplasty: outcomes from a corneal unit compared to national data. Br J Ophthalmol 90:726–731CrossRef
14.
go back to reference Stewart RMK, Jones MNA, Batterbury M, Tole D, Larkin DF, Kaye SB (2011) NHSBT ocular tissue advisory group and contributing ophthalmologists (OTAG Audit Study 9). Effect of glaucoma on corneal graft survival according to indication for penetrating keratoplasty. Am J Ophthalmol 151:257–262CrossRefPubMed Stewart RMK, Jones MNA, Batterbury M, Tole D, Larkin DF, Kaye SB (2011) NHSBT ocular tissue advisory group and contributing ophthalmologists (OTAG Audit Study 9). Effect of glaucoma on corneal graft survival according to indication for penetrating keratoplasty. Am J Ophthalmol 151:257–262CrossRefPubMed
15.
go back to reference Reinhard T, Kallmann C, Cepin A, Godehardt E, Sundmacher R (1997) The influence of glaucoma history on graft survival after penetrating keratoplasty. Graefes Arch Clin Exp Ophthalmol 235:553–557CrossRefPubMed Reinhard T, Kallmann C, Cepin A, Godehardt E, Sundmacher R (1997) The influence of glaucoma history on graft survival after penetrating keratoplasty. Graefes Arch Clin Exp Ophthalmol 235:553–557CrossRefPubMed
16.
go back to reference Maguire MG, Stark WJ, Gottsch JD, Stulting RD, Sugar A, Fink NE, Schwartz A (1994) Collaborative corneal transplantation studies research group. Risk factors for corneal graft failure and rejection in the collaborative corneal transplantation studies. Ophthalmology 101:1536–1547CrossRefPubMed Maguire MG, Stark WJ, Gottsch JD, Stulting RD, Sugar A, Fink NE, Schwartz A (1994) Collaborative corneal transplantation studies research group. Risk factors for corneal graft failure and rejection in the collaborative corneal transplantation studies. Ophthalmology 101:1536–1547CrossRefPubMed
17.
go back to reference Wiaux C, Baghdasaryan E, Lee OL, Bourges JL, Deng SX, Yu F, Aldave AJ (2011) Outcomes after Descemet stripping endothelial keratoplasty in glaucoma pateints with previous trabeculectomy and tube shunt implantation. Cornea 30:1304–1311CrossRefPubMed Wiaux C, Baghdasaryan E, Lee OL, Bourges JL, Deng SX, Yu F, Aldave AJ (2011) Outcomes after Descemet stripping endothelial keratoplasty in glaucoma pateints with previous trabeculectomy and tube shunt implantation. Cornea 30:1304–1311CrossRefPubMed
18.
go back to reference Lieberman RA, Maris PJ Jr, Monroe HM, Al-Aswad LA, Bansal R, Lopez R, Florakis GJ (2012) Corneal graft survival and intraocular pressure control in coexisting penetrating keratoplasty and pars plana Ahmed Glaucoma Valves. Cornea 31:350–358CrossRefPubMed Lieberman RA, Maris PJ Jr, Monroe HM, Al-Aswad LA, Bansal R, Lopez R, Florakis GJ (2012) Corneal graft survival and intraocular pressure control in coexisting penetrating keratoplasty and pars plana Ahmed Glaucoma Valves. Cornea 31:350–358CrossRefPubMed
19.
go back to reference Knape RM, Szymarek TN, Tuli SS, Driebe WT, Sherwood MB, Smith MF (2012) Five-year outcomes of eyes with glaucoma drainage device and penetrating keratoplasty. J Glaucoma 21:608–614CrossRefPubMedPubMedCentral Knape RM, Szymarek TN, Tuli SS, Driebe WT, Sherwood MB, Smith MF (2012) Five-year outcomes of eyes with glaucoma drainage device and penetrating keratoplasty. J Glaucoma 21:608–614CrossRefPubMedPubMedCentral
20.
go back to reference Kwon YH, Taylor JM, Hong S, Honkanen RA, Zimmerman MB, Alward WL, Sutphin JE (2001) Long-term results of eyes with penetrating keratoplasty and glaucoma drainage tube implant. Ophthalmology 108:272–278CrossRefPubMed Kwon YH, Taylor JM, Hong S, Honkanen RA, Zimmerman MB, Alward WL, Sutphin JE (2001) Long-term results of eyes with penetrating keratoplasty and glaucoma drainage tube implant. Ophthalmology 108:272–278CrossRefPubMed
21.
go back to reference Topouzis F, Coleman AL, Choplin N, Bethlem MM, Hill R, Yu F, Panek WC, Wilson MR (1999) Follow-up of the original cohort with the Ahmed glaucoma valve implant. Am J Ophthalmol 128:198–204CrossRefPubMed Topouzis F, Coleman AL, Choplin N, Bethlem MM, Hill R, Yu F, Panek WC, Wilson MR (1999) Follow-up of the original cohort with the Ahmed glaucoma valve implant. Am J Ophthalmol 128:198–204CrossRefPubMed
22.
go back to reference Witmer MT, Tiedeman JS, Oisakovsky LA, Conaway MR, Prum BE (2010) Long-term intraocular pressure control and corneal graft survival in eyes with a pars plana Baerveldt implant and corneal transplant. J Glaucoma 19:124–131CrossRefPubMed Witmer MT, Tiedeman JS, Oisakovsky LA, Conaway MR, Prum BE (2010) Long-term intraocular pressure control and corneal graft survival in eyes with a pars plana Baerveldt implant and corneal transplant. J Glaucoma 19:124–131CrossRefPubMed
23.
go back to reference Thompson RW Jr, Price MO, Bowers PJ, Price FW Jr (2003) Long-term graft survival after penetrating keratoplasty. Ophthalmology 110:1396–1402CrossRefPubMed Thompson RW Jr, Price MO, Bowers PJ, Price FW Jr (2003) Long-term graft survival after penetrating keratoplasty. Ophthalmology 110:1396–1402CrossRefPubMed
24.
go back to reference Ing JJ, Ing HH, Nelson LR, Hodge DO, Bourne WM (1998) Ten-year postoperative results of penetrating keratoplasty. Ophthalmology 105:1855–1865CrossRefPubMed Ing JJ, Ing HH, Nelson LR, Hodge DO, Bourne WM (1998) Ten-year postoperative results of penetrating keratoplasty. Ophthalmology 105:1855–1865CrossRefPubMed
25.
go back to reference Price FW Jr, Whitson WE, Collins KS, Marks RG (1993) Five-year corneal graft survival. A large, single-center patient cohort. Arch Ophthalmol 111:799–805CrossRefPubMed Price FW Jr, Whitson WE, Collins KS, Marks RG (1993) Five-year corneal graft survival. A large, single-center patient cohort. Arch Ophthalmol 111:799–805CrossRefPubMed
26.
go back to reference Ramulu PY, Corcoran KJ, Corcoran SL, Robin AL (2007) Utilization of various glaucoma surgeries and procedures in Medicare beneficiaries from 1995-2004. Ophthalmology 114:2265–2270CrossRefPubMed Ramulu PY, Corcoran KJ, Corcoran SL, Robin AL (2007) Utilization of various glaucoma surgeries and procedures in Medicare beneficiaries from 1995-2004. Ophthalmology 114:2265–2270CrossRefPubMed
27.
go back to reference Rosenberg LF, Krupin T (1996) Implants in glaucoma surgery. In: Ritch R, Shields MB, Krupin T (eds) The glaucomas, 2nd edn. Mosby, Philadelphia, pp 1783–1807 Rosenberg LF, Krupin T (1996) Implants in glaucoma surgery. In: Ritch R, Shields MB, Krupin T (eds) The glaucomas, 2nd edn. Mosby, Philadelphia, pp 1783–1807
28.
go back to reference Sugar A, Tanner JP, Dontchev M, Tennant B, Schultze RL, Dunn SP, Lindquist TD, Gal RL, Beck RW, Kollman C, Mannis MJ (2009) Holland EJ; Cornea Donor Study Investigator Group. Recipient risk factors for graft failure in the cornea donor study. Ophthalmology 116:1023–1028CrossRefPubMedPubMedCentral Sugar A, Tanner JP, Dontchev M, Tennant B, Schultze RL, Dunn SP, Lindquist TD, Gal RL, Beck RW, Kollman C, Mannis MJ (2009) Holland EJ; Cornea Donor Study Investigator Group. Recipient risk factors for graft failure in the cornea donor study. Ophthalmology 116:1023–1028CrossRefPubMedPubMedCentral
29.
go back to reference Kim P, Amiran MD, Lichtinger A, Yeung SN, Slomovic AR, Rootman DS (2012) Outcomes of Descemet stripping automated endothelial keratoplasty in patients with previous glaucoma drainage device insertion. Cornea 31:172–175CrossRefPubMed Kim P, Amiran MD, Lichtinger A, Yeung SN, Slomovic AR, Rootman DS (2012) Outcomes of Descemet stripping automated endothelial keratoplasty in patients with previous glaucoma drainage device insertion. Cornea 31:172–175CrossRefPubMed
30.
go back to reference Aldave AJ, Chen JL, Zaman AS, Deng SX, Yu F (2014) Outcomes after DSEK in 101 eyes with previous trabeculectomy and tube shunt implantation. Cornea 33:223–229CrossRefPubMed Aldave AJ, Chen JL, Zaman AS, Deng SX, Yu F (2014) Outcomes after DSEK in 101 eyes with previous trabeculectomy and tube shunt implantation. Cornea 33:223–229CrossRefPubMed
31.
go back to reference Forstot SL, Binder PS, Fitzgerald C, Kaufman HE (1975) The incidence of retinal detachment after penetrating keratoplasty. Am J Ophthalmol 80:102–105CrossRefPubMed Forstot SL, Binder PS, Fitzgerald C, Kaufman HE (1975) The incidence of retinal detachment after penetrating keratoplasty. Am J Ophthalmol 80:102–105CrossRefPubMed
32.
go back to reference Baudouin C (1996) Side effects of antiglaucomatous drugs on the ocular surface. Curr Opin Ophthalmol 7:80–86CrossRefPubMed Baudouin C (1996) Side effects of antiglaucomatous drugs on the ocular surface. Curr Opin Ophthalmol 7:80–86CrossRefPubMed
Metadata
Title
Comparison of graft survival following penetrating keratoplasty and Descemet’s stripping endothelial keratoplasty in eyes with a glaucoma drainage device
Authors
Shawn M. Iverson
Oriel Spierer
George C. Papachristou
William J. Feuer
Wei Shi
David S. Greenfield
Terrence P. O’Brien
Publication date
01-02-2018
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 1/2018
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-017-0451-4

Other articles of this Issue 1/2018

International Ophthalmology 1/2018 Go to the issue