Skip to main content
Top
Published in: International Ophthalmology 2/2014

01-04-2014 | Case Report

Iridodialysis repair: stroke and dock technique

Authors: Sudarshan Khokhar, Shikha Gupta, Gaurav Kumar

Published in: International Ophthalmology | Issue 2/2014

Login to get access

Abstract

Iridodialysis needs to be repaired if it is symptomatic. We describe a new bimanual technique for repair of iridodialysis where a bent 26 gauge (G) needle is used to lift the peripheral iris first. The bevel of the needle then acts as a platform for the 9-0 prolene suture with a straight needle to enable unfolding of the curled up iris by stroking before finally docking the suture needle into the bevel of the 26 G needle. This technique ensures precise scleral fixation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Paton D (1973) Management of iridodialysis. Ophthalmic Surg 4:38–39 Paton D (1973) Management of iridodialysis. Ophthalmic Surg 4:38–39
2.
go back to reference Nunziata BR (1993) Repair of iridodialysis using a 17-millimeter straight needle. Ophthalmic Surg 24:627–629PubMed Nunziata BR (1993) Repair of iridodialysis using a 17-millimeter straight needle. Ophthalmic Surg 24:627–629PubMed
3.
go back to reference Wachler BB, Krueger RR (1996) Double-armed McCannell suture for repair of traumatic iridodialysis. Am J Ophthalmol 122:109–110PubMed Wachler BB, Krueger RR (1996) Double-armed McCannell suture for repair of traumatic iridodialysis. Am J Ophthalmol 122:109–110PubMed
4.
go back to reference Richards JC, Kennedy CJ (2006) Sutureless technique for repair of traumatic iridodialysis. Ophthalmic Surg Lasers Imaging 37(6):508PubMed Richards JC, Kennedy CJ (2006) Sutureless technique for repair of traumatic iridodialysis. Ophthalmic Surg Lasers Imaging 37(6):508PubMed
5.
go back to reference Snyder ME, Lindsell LB (2011) Nonappositional repair of iridodialysis. J Cataract Refract Surg 37:625–628PubMedCrossRef Snyder ME, Lindsell LB (2011) Nonappositional repair of iridodialysis. J Cataract Refract Surg 37:625–628PubMedCrossRef
6.
go back to reference Bardak Y, Ozerturk Y, Durmus M, Mensiz E, Aytuluner E (2000) Closed chamber iridodialysis repair using a needle with a distal hole. J Cataract Refract Surg 26:173–176PubMedCrossRef Bardak Y, Ozerturk Y, Durmus M, Mensiz E, Aytuluner E (2000) Closed chamber iridodialysis repair using a needle with a distal hole. J Cataract Refract Surg 26:173–176PubMedCrossRef
Metadata
Title
Iridodialysis repair: stroke and dock technique
Authors
Sudarshan Khokhar
Shikha Gupta
Gaurav Kumar
Publication date
01-04-2014
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 2/2014
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-013-9785-8

Other articles of this Issue 2/2014

International Ophthalmology 2/2014 Go to the issue