Skip to main content
Top
Published in: Japanese Journal of Ophthalmology 4/2019

01-07-2019 | Retinal Detachment | Clinical Investigation

Comparison between refractive outcomes between macula-on and macula-off retinal detachments after phaco-vitrectomy

Authors: Kang Yeun Pak, Keun Heung Park, Sung Who Park, Ik Soo Byon, Ji Eun Lee

Published in: Japanese Journal of Ophthalmology | Issue 4/2019

Login to get access

Abstract

Purpose

To evaluate axial length (AL) measurements and refractive outcomes in vitrectomy combined with cataract operation for rhegmatogenous retinal detachment (RRD) with wholly detached macula.

Study design

Retrospective, consecutive, comparative, clinical study.

Methods

We reviewed the data of patients treated by vitrectomy combined with cataract operation for RRD. The group “Attach” (n=31) consisted of eyes in which retina was not detached within 1.5 disc diameters from the foveal center, and the group “Detach” (n=33) consisted of eyes in which that area was detached entirely. Only those eyes inthe group “Detach”, only the eyes (n=20) which AL were measured similar to those fellow eyes were compared to the group “Attach” (n=31). Refractive shift (RS) was defined as the average of the difference between postoperative spherical equivalent (SE) and predicted SE.

Results

AL was well measured by A-scan ultrasonography (A-scan) in all 31 eyes of the group “Attach” and their RS was ‒0.57 diopters (D). AL was measured by A-scan similar to the fellow eye in 20 of 33 eyes (60.6%) of the group “Detach”, and the RS was ‒0.09 D. The AL difference as much as central subfield macular thickness (about 300um) can make this difference of RS (0.48 D, P=0.025)

Conclusion

When AL can be measured by A-scan similar to its fellow eye in RRD with wholly detached macula, RS would be smaller than that of the wholly attached macula after phacovitrectomy. It assumed that AL was measured from the RPE under the detached macula in RRD with wholly detached macula.
Literature
1.
go back to reference Park SW, Kwon HJ, Kim HY, Byon IS, Lee JE, Oum BS. Comparison of scleral buckling and vitrectomy using wide angle viewing system for rhegmatogenous retinal detachment in patients older than 35 years. BMC Ophthalmol. 2015;15:1.CrossRef Park SW, Kwon HJ, Kim HY, Byon IS, Lee JE, Oum BS. Comparison of scleral buckling and vitrectomy using wide angle viewing system for rhegmatogenous retinal detachment in patients older than 35 years. BMC Ophthalmol. 2015;15:1.CrossRef
2.
go back to reference Rose LT, Moshegov CN. Comparison of the Zeiss IOLMaster and applanation A-scan ultrasound: biometry for intraocular lens calculation. Clin Exp Ophthalmol. 2003;31:121–4.CrossRefPubMed Rose LT, Moshegov CN. Comparison of the Zeiss IOLMaster and applanation A-scan ultrasound: biometry for intraocular lens calculation. Clin Exp Ophthalmol. 2003;31:121–4.CrossRefPubMed
3.
go back to reference Choi JH, Roh GH. The reproducibility and accuracy of biometry parameter measurement from IOL master (R). J Korean Ophthalmol Soci. 2004;45:1665–73. Choi JH, Roh GH. The reproducibility and accuracy of biometry parameter measurement from IOL master (R). J Korean Ophthalmol Soci. 2004;45:1665–73.
4.
go back to reference Rahman R, Bong CX, Stephenson J. Accuracy of intraocular lens power estimation in eyes having phacovitrectomy for rhegmatogenous retinal detachment. Retina. 2014;34:1415–20.CrossRefPubMed Rahman R, Bong CX, Stephenson J. Accuracy of intraocular lens power estimation in eyes having phacovitrectomy for rhegmatogenous retinal detachment. Retina. 2014;34:1415–20.CrossRefPubMed
5.
go back to reference Cho KH, Park IW, Kwon SI. Changes in postoperative refractive outcomes following combined phacoemulsification and pars plana vitrectomy for rhegmatogenous retinal detachment. Am J Ophthalmol. 2014;158:251–6.CrossRefPubMed Cho KH, Park IW, Kwon SI. Changes in postoperative refractive outcomes following combined phacoemulsification and pars plana vitrectomy for rhegmatogenous retinal detachment. Am J Ophthalmol. 2014;158:251–6.CrossRefPubMed
6.
go back to reference Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 1992;18:125–9.CrossRefPubMed Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 1992;18:125–9.CrossRefPubMed
7.
go back to reference Drexler W, Findl O, Menapace R, Rainer G, Vass C, Hitzenberger CK, et al. Partial coherence interferometry: a novel approach to biometry in cataract surgery. Am J Ophthalmol. 1998;126:524–34.CrossRefPubMed Drexler W, Findl O, Menapace R, Rainer G, Vass C, Hitzenberger CK, et al. Partial coherence interferometry: a novel approach to biometry in cataract surgery. Am J Ophthalmol. 1998;126:524–34.CrossRefPubMed
8.
go back to reference Findl O, Drexler W, Menapace R, Hitzenberger CK, Fercher AF. High precision biometry of pseudophakic eyes using partial coherence interferometry. J Cataract Refract Surg. 1998;24:1087–93.CrossRefPubMed Findl O, Drexler W, Menapace R, Hitzenberger CK, Fercher AF. High precision biometry of pseudophakic eyes using partial coherence interferometry. J Cataract Refract Surg. 1998;24:1087–93.CrossRefPubMed
9.
go back to reference Shin JA, Chung SK. Comparison of the refractive results measured by ultrasound and partial coherence interferometers. J Korean Ophthalmol Soc. 2013;54:723–7.CrossRef Shin JA, Chung SK. Comparison of the refractive results measured by ultrasound and partial coherence interferometers. J Korean Ophthalmol Soc. 2013;54:723–7.CrossRef
10.
go back to reference Suzuki Y, Sakuraba T, Mizutani H, Matsuhashi H, Nakazawa M. Postoperative refractive error after simultaneous vitrectomy and cataract surgery. Ophthalmic Surg Lasers. 2000;31:271–5.PubMed Suzuki Y, Sakuraba T, Mizutani H, Matsuhashi H, Nakazawa M. Postoperative refractive error after simultaneous vitrectomy and cataract surgery. Ophthalmic Surg Lasers. 2000;31:271–5.PubMed
11.
go back to reference Patel D, Rahman R, Kumarasamy M. Accuracy of intraocular lens power estimation in eyes having phacovitrectomy for macular holes. J Cataract Refract Surg. 2007;33:1760–2.CrossRefPubMed Patel D, Rahman R, Kumarasamy M. Accuracy of intraocular lens power estimation in eyes having phacovitrectomy for macular holes. J Cataract Refract Surg. 2007;33:1760–2.CrossRefPubMed
12.
go back to reference Jeoung JW, Chung H, Yu HG. Factors influencing refractive outcomes after combined phacoemulsification and pars plana vitrectomy: results of a prospective study. J Cataract Refract Surg. 2007;33:108–14.CrossRefPubMed Jeoung JW, Chung H, Yu HG. Factors influencing refractive outcomes after combined phacoemulsification and pars plana vitrectomy: results of a prospective study. J Cataract Refract Surg. 2007;33:108–14.CrossRefPubMed
13.
go back to reference Abou-Shousha M, Helaly HA, Osman IM. The accuracy of axial length measurements in cases of macula-off retinal detachment. Can J Ophthalmol. 2016;51:108–12.CrossRefPubMed Abou-Shousha M, Helaly HA, Osman IM. The accuracy of axial length measurements in cases of macula-off retinal detachment. Can J Ophthalmol. 2016;51:108–12.CrossRefPubMed
14.
go back to reference Rahman R, Kolb S, Bong CX, Stephenson J. Accuracy of user-adjusted axial length measurements with optical biometry in eyes having combined phacovitrectomy for macular-off rhegmatogenous retinal detachment. J Cataract Refract Surg. 2016;42:1009–14.CrossRefPubMed Rahman R, Kolb S, Bong CX, Stephenson J. Accuracy of user-adjusted axial length measurements with optical biometry in eyes having combined phacovitrectomy for macular-off rhegmatogenous retinal detachment. J Cataract Refract Surg. 2016;42:1009–14.CrossRefPubMed
15.
go back to reference Kim YK, Woo SJ, Hyon JY, Ahn J, Park KH. Refractive outcomes of combined phacovitrectomy and delayed cataract surgery in retinal detachment. Can J Ophthalmol. 2015;50:360–6.CrossRefPubMed Kim YK, Woo SJ, Hyon JY, Ahn J, Park KH. Refractive outcomes of combined phacovitrectomy and delayed cataract surgery in retinal detachment. Can J Ophthalmol. 2015;50:360–6.CrossRefPubMed
Metadata
Title
Comparison between refractive outcomes between macula-on and macula-off retinal detachments after phaco-vitrectomy
Authors
Kang Yeun Pak
Keun Heung Park
Sung Who Park
Ik Soo Byon
Ji Eun Lee
Publication date
01-07-2019
Publisher
Springer Japan
Published in
Japanese Journal of Ophthalmology / Issue 4/2019
Print ISSN: 0021-5155
Electronic ISSN: 1613-2246
DOI
https://doi.org/10.1007/s10384-019-00667-6

Other articles of this Issue 4/2019

Japanese Journal of Ophthalmology 4/2019 Go to the issue