Abstract

Purpose

We investigated the effects on corneal shape of suturing the scleral wound during 23-gauge vitreous surgery.

Methods

We used a corneal topographic modeling system to measure the corneal shape in 39 eyes of 39 patients before and at 1 week, 1 month, and 3 months after performing 23-gauge vitreous surgery. We investigated the immediate postoperative changes and the postoperative changes over time according to whether suturing was performed. Suturing of the scleral wound was required in 20 eyes of 20 patients (suture group) and was not performed in 19 eyes of 19 patients (no-suture group). Spherical equivalent, regular astigmatism, asymmetry, and higher order irregularity components were investigated separately using Fourier analysis of corneal shape data obtained from the topographic modeling system.

Results

The no-suture group showed no significant change in any component at any point after surgery. In the suture group, spherical equivalent, regular astigmatism, asymmetry, and higher order irregularities were all increased 1 week postoperatively, but by 1 month postoperatively, these had all returned to their preoperative states.

Conclusions

If suturing is required during 23-gauge vitreous surgery, patients should be monitored with the understanding that changes in refractive value may occur during the month after surgery owing to changes in corneal shape.
Literature
1.
go back to reference Fujii GY, De Juan E Jr, Humayun MS, Pieramici DJ, Chang TS, Awh C, et al. A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery. Ophthalmology. 2002;109:1807–12.PubMedCrossRef Fujii GY, De Juan E Jr, Humayun MS, Pieramici DJ, Chang TS, Awh C, et al. A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery. Ophthalmology. 2002;109:1807–12.PubMedCrossRef
3.
go back to reference Weinberger D, Lichter H, Loya N, Axer-Siegel R, Muzmacher L, Gabbay U, et al. Corneal topographic changes after retinal and vitreous surgery. Ophthalmology. 1999;106:1521–4.PubMedCrossRef Weinberger D, Lichter H, Loya N, Axer-Siegel R, Muzmacher L, Gabbay U, et al. Corneal topographic changes after retinal and vitreous surgery. Ophthalmology. 1999;106:1521–4.PubMedCrossRef
4.
go back to reference Wirbelauer C, Hoerauf H, Roider J, Laqua H. Corneal shape changes after pars plana vitrectomy. Graefes Arch Clin Exp Ophthalmol. 1998;236:822–8.PubMedCrossRef Wirbelauer C, Hoerauf H, Roider J, Laqua H. Corneal shape changes after pars plana vitrectomy. Graefes Arch Clin Exp Ophthalmol. 1998;236:822–8.PubMedCrossRef
5.
go back to reference Oshika T, Tomidokoro A, Maruo K, Tokunaga T, Miyata N. Quantitative evaluation of irregular astigmatism by fourier series harmonic analysis of videokeratography data. Invest Ophthalmol Vis Sci. 1998;39:705–9.PubMed Oshika T, Tomidokoro A, Maruo K, Tokunaga T, Miyata N. Quantitative evaluation of irregular astigmatism by fourier series harmonic analysis of videokeratography data. Invest Ophthalmol Vis Sci. 1998;39:705–9.PubMed
6.
go back to reference Tomidokoro A, Oshika T. Quantitative assessment of videokeratography data using fourier series harmonic analysis. Cornea. 2004;23(suppl 8):S71–7.PubMedCrossRef Tomidokoro A, Oshika T. Quantitative assessment of videokeratography data using fourier series harmonic analysis. Cornea. 2004;23(suppl 8):S71–7.PubMedCrossRef
7.
go back to reference Tanabe T, Tomidokoro A, Samejima T, Miyata K, Sato M, Kaji Y, et al. Corneal regular and irregular astigmatism assessed by Fourier analysis of videokeratography data in normal and pathologic eyes. Ophthalmology. 2004;111:752–7.PubMedCrossRef Tanabe T, Tomidokoro A, Samejima T, Miyata K, Sato M, Kaji Y, et al. Corneal regular and irregular astigmatism assessed by Fourier analysis of videokeratography data in normal and pathologic eyes. Ophthalmology. 2004;111:752–7.PubMedCrossRef
8.
go back to reference Saito A, Gotoh N, Matsushima H, Senoo T. Evaluation of surgically induced astigmatism following small-incision and micro-incision cataract surgery (in Japanese). IOL&RS. 2009;23:379–82. Saito A, Gotoh N, Matsushima H, Senoo T. Evaluation of surgically induced astigmatism following small-incision and micro-incision cataract surgery (in Japanese). IOL&RS. 2009;23:379–82.
9.
go back to reference Yanyali A, Horozoglu F, Macin A, Bozkurt KT, Aykut V, Acar BT, et al. Corneal topographic changes after transconjunctival 23-gauge sutureless vitrectomy. Int Ophthalmol. 2011;31:277–82.PubMedCrossRef Yanyali A, Horozoglu F, Macin A, Bozkurt KT, Aykut V, Acar BT, et al. Corneal topographic changes after transconjunctival 23-gauge sutureless vitrectomy. Int Ophthalmol. 2011;31:277–82.PubMedCrossRef
10.
go back to reference Kadonosono K, Yamakawa T, Uchio E, Yanagi Y, Tamaki Y, Araie M. Comparison of visual function after epiretinal membrane removal by 20-gauge and 25-gauge vitrectomy. Am J Ophthalmol. 2006;142:513–5.PubMedCrossRef Kadonosono K, Yamakawa T, Uchio E, Yanagi Y, Tamaki Y, Araie M. Comparison of visual function after epiretinal membrane removal by 20-gauge and 25-gauge vitrectomy. Am J Ophthalmol. 2006;142:513–5.PubMedCrossRef
11.
go back to reference Okamoto F, Okamoto C, Sakata N, Hiratsuka K, Yamane N, Hiraoka T, et al. Changes in corneal topography after 25-gauge transconjunctival sutureless vitrectomy versus after 20-gauge standard vitrectomy. Ophthalmology. 2007;114:2138–41.PubMedCrossRef Okamoto F, Okamoto C, Sakata N, Hiratsuka K, Yamane N, Hiraoka T, et al. Changes in corneal topography after 25-gauge transconjunctival sutureless vitrectomy versus after 20-gauge standard vitrectomy. Ophthalmology. 2007;114:2138–41.PubMedCrossRef
Metadata
Title
Effect on corneal shape of suturing the scleral wound during 23-gauge vitreous surgery
Authors
Tomohiro Shibata
Akira Watanabe
Hirotsugu Takashina
Hiroshi Tsuneoka
Publication date
01-09-2012
Publisher
Springer Japan
Published in
Japanese Journal of Ophthalmology / Issue 5/2012
Print ISSN: 0021-5155
Electronic ISSN: 1613-2246
DOI
https://doi.org/10.1007/s10384-012-0169-9

Other articles of this Issue 5/2012

Japanese Journal of Ophthalmology 5/2012 Go to the issue