Skip to main content
Top
Published in: European Surgery 4/2013

Open Access 01-08-2013 | Original Article

Comparison of regenerated and non-regenerated oxidized cellulose hemostatic agents

Authors: K. M. Lewis, DVM, D. Spazierer, PhD, M. D. Urban, HT (ASCP), L. Lin, PhD, H. Redl, PhD, A. Goppelt, PhD

Published in: European Surgery | Issue 4/2013

Login to get access

Summary

Background

Oxidized cellulose is a well known and widely used surgical hemostat. It is available in many forms, but manufactured using either a nonregenerated or regenerated process.

Objective

This study compares the fiber structure, pH in solution, bactericidal effectiveness, and hemostatic effectiveness of an oxidized nonregenerated cellulose (ONRC; Traumastem®) and an oxidized regenerated cellulose (ORC; Surgicel® Original).

Methods

In vitro, fiber structures were compared using scanning electron microscopy, pH of phosphate buffer solution (PBS) and human plasma were measured after each cellulose was submerged, and bactericidal effect was measured by plating each cellulose with four bacteria. In vivo, time to hemostasis and hemostatic success were compared using a general surgery nonheparinized porcine liver abrasion model and a peripheral vascular surgery heparinized leporine femoral vessel bleeding model.

Results

Ultrastructure of ONRC fiber is frayed, while ORC is smooth. ORC pH is statistically more acidic than ONRC in PBS, but equal in plasma. No difference in bactericidal effectiveness was observed. In vivo, ONRC provided superior time to hemostasis relative to ORC (211.2 vs 384.6 s, N = 60/group) in the general surgery model; and superior hemostatic success relative to ORC at 30 (60 vs. 15 %; OR: 13.5; 95 % CI: 3.72–49.1, N = 40/group), 60 (85 vs. 37.5 %; OR: 12.3; 95 % CI: 3.66–41.6), and 90 s (97.5 vs 70.0 %; OR: 21.1, 95 % CI: 2.28–195.9) in the peripheral vascular model.

Conclusion

ONRC provides superior hemostasis and equivalent bactericidal effectiveness relative to ORC, which is likely due to its fiber structure than acidity.
Literature
1.
go back to reference Spotnitz WD, Burks SG. Hemostats, sealants, and adhesives II: update as well as how and when to use the components of the surgical toolbox. Clin Appl Thromb Hemost. 2010;16:497–514.PubMedCrossRef Spotnitz WD, Burks SG. Hemostats, sealants, and adhesives II: update as well as how and when to use the components of the surgical toolbox. Clin Appl Thromb Hemost. 2010;16:497–514.PubMedCrossRef
2.
go back to reference Frantz VK, Lattes R. Oxidized cellulose-absorbable gauze (cellulosic acid). JAMA. 1945;129:798–801.CrossRef Frantz VK, Lattes R. Oxidized cellulose-absorbable gauze (cellulosic acid). JAMA. 1945;129:798–801.CrossRef
3.
go back to reference Pierce AM, Wiebkin OW, Wilson DF. Surgicel®: its fate following implantation. J Oral Pathol. 1984;13(6):661–70.PubMedCrossRef Pierce AM, Wiebkin OW, Wilson DF. Surgicel®: its fate following implantation. J Oral Pathol. 1984;13(6):661–70.PubMedCrossRef
4.
go back to reference Miller JM, Jackson DA, Collier CS. An investigation of the chemical reactions of oxidized regenerated cellulose. Exp Med Surgery. 1961;19:196. Miller JM, Jackson DA, Collier CS. An investigation of the chemical reactions of oxidized regenerated cellulose. Exp Med Surgery. 1961;19:196.
5.
go back to reference Dimitrijevich SD, Tatarko M, Gracy RW. Biodegradation of oxidized regenerated cellulose. Carbohydr Res. 1990;195:247–56.PubMedCrossRef Dimitrijevich SD, Tatarko M, Gracy RW. Biodegradation of oxidized regenerated cellulose. Carbohydr Res. 1990;195:247–56.PubMedCrossRef
6.
go back to reference Dimitrijevich SD, Tatarko M, Gracy RW, Wise GE. Oakford LX. In vivo degradation of oxidized, regenerated cellulose. Carbohydr Res. 1990;198:331–41.PubMedCrossRef Dimitrijevich SD, Tatarko M, Gracy RW, Wise GE. Oakford LX. In vivo degradation of oxidized, regenerated cellulose. Carbohydr Res. 1990;198:331–41.PubMedCrossRef
7.
go back to reference Dineen P. The effect of oxidized regenerated cellulose on experimental infected splenotomies. J Surg Res. 1977;23:114–6.PubMedCrossRef Dineen P. The effect of oxidized regenerated cellulose on experimental infected splenotomies. J Surg Res. 1977;23:114–6.PubMedCrossRef
8.
go back to reference Abaev Y, Kaputsky V, Adarchenko A, Sobeshchuk O. Mechanism of antibacterial effects of monocarboxyl cellulose and other ion exchange derivatives of cellulose. Antibiot Med Bioteckhnol. 1986;31:624–8. Abaev Y, Kaputsky V, Adarchenko A, Sobeshchuk O. Mechanism of antibacterial effects of monocarboxyl cellulose and other ion exchange derivatives of cellulose. Antibiot Med Bioteckhnol. 1986;31:624–8.
9.
go back to reference Spangler D, Rothenburger S, Nguyen K, Jampani H, Weiss S. Bhende S. In vitro antimicrobial activity of oxidized regenerated cellulose against antibiotic-resistant microorganisms. Surg Infect. 2003;4:255–62.CrossRef Spangler D, Rothenburger S, Nguyen K, Jampani H, Weiss S. Bhende S. In vitro antimicrobial activity of oxidized regenerated cellulose against antibiotic-resistant microorganisms. Surg Infect. 2003;4:255–62.CrossRef
10.
go back to reference Adams G, Manson J, Hasselblad V, Shaw LK, Lawson JH. Acute in-vivo evaluation of bleeding with GelfoamTM plus saline and GelfoamTM plus human thrombin using a liver square lesion model in swine. J Thromb Thrombolysis. 2009;28:1–5.PubMedCrossRef Adams G, Manson J, Hasselblad V, Shaw LK, Lawson JH. Acute in-vivo evaluation of bleeding with GelfoamTM plus saline and GelfoamTM plus human thrombin using a liver square lesion model in swine. J Thromb Thrombolysis. 2009;28:1–5.PubMedCrossRef
11.
go back to reference Thornton JA. Estimation of blood loss during surgery. Ann R Coll Surg Engl. 1963;33:164–74.PubMed Thornton JA. Estimation of blood loss during surgery. Ann R Coll Surg Engl. 1963;33:164–74.PubMed
12.
go back to reference Ribalta T, McCutcheon IE, Neto AG, Gupta D, Kumar AJ, Biddle DA, Langford LA, Bruner JM, Leeds NE, Fuller G. Textiloma (Gossypiboma) mimicking recurrent intracranial tumor. Arch Pathol Lab Med. 2004;128:749–58.PubMed Ribalta T, McCutcheon IE, Neto AG, Gupta D, Kumar AJ, Biddle DA, Langford LA, Bruner JM, Leeds NE, Fuller G. Textiloma (Gossypiboma) mimicking recurrent intracranial tumor. Arch Pathol Lab Med. 2004;128:749–58.PubMed
13.
go back to reference Kheirabadi BS, Arnaud F, McCarron R, Murdock AD, Hodge DL, Ritter B, Dubick MA, Blackbourne LH. Development of a standard swine hemorrhage model for efficacy assessment of topical hemostatic agents. J Trauma. 2011;71(1 Suppl):S139–46.PubMedCrossRef Kheirabadi BS, Arnaud F, McCarron R, Murdock AD, Hodge DL, Ritter B, Dubick MA, Blackbourne LH. Development of a standard swine hemorrhage model for efficacy assessment of topical hemostatic agents. J Trauma. 2011;71(1 Suppl):S139–46.PubMedCrossRef
14.
go back to reference Mabry CD, Thompson BW, Read RC. Activated clotting time (ACT) monitoring of intraoperative heparinization in peripheral vascular surgery. Am J Surg. 1979;138(6):894–900.PubMedCrossRef Mabry CD, Thompson BW, Read RC. Activated clotting time (ACT) monitoring of intraoperative heparinization in peripheral vascular surgery. Am J Surg. 1979;138(6):894–900.PubMedCrossRef
15.
go back to reference Vytrasova J, Tylsova A, Brozkova I, Cervenka L, Pejchalova M, Havelka P. Antimicrobial effect of oxidized cellulose salts. J Ind Microbiol Biotechnol. 2008;35:1247–52.PubMedCrossRef Vytrasova J, Tylsova A, Brozkova I, Cervenka L, Pejchalova M, Havelka P. Antimicrobial effect of oxidized cellulose salts. J Ind Microbiol Biotechnol. 2008;35:1247–52.PubMedCrossRef
Metadata
Title
Comparison of regenerated and non-regenerated oxidized cellulose hemostatic agents
Authors
K. M. Lewis, DVM
D. Spazierer, PhD
M. D. Urban, HT (ASCP)
L. Lin, PhD
H. Redl, PhD
A. Goppelt, PhD
Publication date
01-08-2013
Publisher
Springer Vienna
Published in
European Surgery / Issue 4/2013
Print ISSN: 1682-8631
Electronic ISSN: 1682-4016
DOI
https://doi.org/10.1007/s10353-013-0222-z

Other articles of this Issue 4/2013

European Surgery 4/2013 Go to the issue